5. AIR SIGNAL LINE CONNECTIONS
5.1 System Configuration with LW76E Register Equipped Meter
(1-step open/2-step close or 2-step open/2-step close)
NOTE: For simplicity's sake, the Ultra OVAL (*) with a batch control feature is shown here in an upright
position. In practice, the flowmeter should be installed in the physical orientation shown in Sections
4.2 and 4.3.
Flow Direction
IN
OUT 1
EXH
ULTRA OVAL with Batch Controller
(LW76E)
Filter/Reducing Valve
OUT 2
To Pump
(Contact-closure
signal)
SV
MV
FPD1
Air Press. to Valve *2
Signal Air Press.
0.20 to 0.69MPa
Air
Directional
Valve
Double Torque Cylinder
Ball Valve
※
1
Note: *2 depends on the specification of the valve.
Fig. 5.1
NOTE: When combined with OVAL pneumatic-electrical switch (Model FPD1), the pump can be
interlocked.
For complete details, see the pneumatic-electrical switch instruction manual.
5.2 Air Signal Line Connections
The register contains a pneumatic circuits
to which air signal lines of copper tubing
are connected through their ports below the
register body.
- Air pressure:
0.20 to 0.69MPa
(adjusted to shutoff valve
specification.)
(Must be clean air)
- Air tubing diam.: Use
φ
6 ×
φ
4 copper tubing.
(Bite-type couplings
(Rc1/8) are provided.)
- Output air connections
OUT 1: Main valve (MV) open signal
OUT 2: Small valve (SV) close signal
IMPORTANT: At the supply air
connection, be sure to
provide a reducing valve
furnished with a filter
(Model 1301-8002).
EXTERNAL
GND TERMINAL
EXH
(EXHAUST)
OUT 1 OPEN SIGNAL
IN AIR SUPPLY
OUT 2 CLOSE SIGNAL
Fig. 5.2