D-555-3-E
0
(3) Space Saving Arrangement
If required straight pipe space is not obtainable upstream of the vortex flowmeter due to existing restrictions on
installation location, the OVAL Honey Vane S combined with a short pipe may be used to get around the space
problem.
• Honey Vane Outline Dimensions
Honey Vane "S"
Honey Vane "L"
t
φ
D
L
t
Nom
Dia.
φ
D*
Honey Vane "S"
Honey Vane "L"
t
L
5
74
3.5
00
40
89
5.4
30
50
04
6.9
400
80
34
0.
640
00
59
3.3
800
* Dimensions with JIS 10K
Fig.5.1
Unit in mm
(4) Installation
①
Required straight pipe length
Provide at least 8D between the flowmeter and
Honey Vane S where D is the straight pipe diameter.
②
Installation (wafer type)
Sandwich between flanges (see figure below).
NOTE: Customer to furnish connecting bolts, nuts
and gasket for the pipe.
Regarding the bolts and nuts used for
connecting JPI flange, adopt unified screw
threads. If you want to use metric screw
threads, contact OVAL.
Honey Vane S
FLOW
Honey Vane S
Flowmeter
Short pipe
Min.8D
Honey Vane S
FLOW
Honey Vane S
Flowmeter
Short pipe
Min.8D
Fig.5.2
Fig.5.3