background image

 

♦ 

Real-time weight display for net and gross loads with automatic memorization. 

♦ 

Management of the weight measurements through the instrument’s database. 

♦ 

Printing of the daily, weekly or monthly load data. 

♦ 

24 Vdc direct power supply with a maximum consumption of 0.5A. 

♦ 

Relay control output for connecting an optical warning device for programmable 
load limits. 

♦ 

The system is entirely waterproof, with a solid construction suited to withstand 
extreme working conditions. 

♦ 

Complete safety of the system, since it does not affect any vital part of the vehi-
cle. 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF BUTTON: Button for switching the LANX HD

®

 display on or off. 

F  BUTTON:  Button for selecting the main functions: operator sel., print loads, de-
lete load (PIN CODE unlock), loads Database, diagnostic, edit materials, edit opera-
tors and setup (PIN CODE unlock). Furthermore, this button is also used to exit the 
various functions and return to the weighing mode. 
TARE BUTTON: Button used to setup the tare. 
BUTTON    : Button for scrolling (up) through the functions. 
BUTTON    : Same function as above (scrolling down). 
MATERIAL BUTTON: button used to select materials. 
OK  BUTTON:  
Button used to confirm the selected function. Also used for viewing 
the net or gross weight of the vehicle. 

1

  Features

 

2

  Display Buttons

 

ON/OFF 

Functions menu 

Exit from functions 

     direction Up 

     direction Down 

OK: confirm data 

OK: Net/Gross 

Material 

Tare 

Содержание Lanx HD

Страница 1: ...on board weighing during loading Productivity control Automatic weighing Protection against early wear of the vehicle Reusable system User Guide User Guide User Guide User Guide Lanx HD only for heavy...

Страница 2: ...2...

Страница 3: ...ls 09 4 7 Edit operators 09 4 8 Tare 10 4 9 Materials 10 5 Setup Functions PIN CODE unlock 10 5 1 Weighing delay 10 5 2 Sensitivity 11 5 3 Language 11 5 4 Unit of measure 11 5 5 Sec TX system Ext 12 5...

Страница 4: ...switching the LANX HD display on or off F BUTTON Button for selecting the main functions operator sel print loads de lete load PIN CODE unlock loads Database diagnostic edit materials edit opera tors...

Страница 5: ...to select the operator or the loading desti nations Press the OK button to confirm the operation 4 2 Print loads This function allows the user to print the weights measured during the day The date tim...

Страница 6: ...ve data E g a SAVE LOADS DB allows to save the weights made through a USB Flash Drive device Press the Functions button and the and buttons until the following appears on the display Press the OK butt...

Страница 7: ...ys c DAILY PRT TOT allows the user to print the totals of all the weight meas urements made in a single day or within an interval of days Press OK to display Use the and buttons to change the number o...

Страница 8: ...bration The user is able to control the operat ing pressures of the vehicle after calibration Press the Functions button and the and buttons until the following appears on the display Press the OK but...

Страница 9: ...destina tions Press the Functions button and the and buttons until the following appears on the display Press the OK button to select the operator destination Press the and buttons to scroll the chara...

Страница 10: ...ssary to enter a protective PIN CODE to unlock the functions See the Calibration manual They can be used to perform the calibration set the load limits for external alarms enter the weighing delay mod...

Страница 11: ...ns button several times to exit this function 5 4 Unit of measure This function determines the chosen unit of measure for the display weight which can be either kilograms tonnes or lbs On the printed...

Страница 12: ...um correction allowed is 10 Enter the Setup menu as described at the beginning of section 5 and press and until the following appears on the display Press the OK button and use the and buttons to sele...

Страница 13: ...the following appears on the display Press OK to enable the fixed alarm Press OK to disable the fixed alarm To set a value press OK and hold down or until the desired value is displayed then press OK...

Страница 14: ...isplay Press the OK button to display the 1st sensor Press the OK button and hold down or to set the desired value Press the OK button and to display the 2nd sensor Press the OK button and hold down o...

Страница 15: ...e Before performing maintenance on the truck make sure that the Sys tem is completely disconnected In particular when performing maintenance changing air spring lev elling valves or leaf spring suspen...

Страница 16: ...ourney time during the warranty period The instruments to repair replace or change must be returned to the vendor head office and in case of technical intervention in the utilization place the relativ...

Страница 17: ...he following parts articles of harmonized standards and regulation have been applied EN55022 class A EN 55024 EN 55022 Enclosure radiated emission EN 55022 DC mains conducted emissions EN 61000 4 3 En...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Отзывы: