background image

13

 

Outdoor Lifestyles by Hearth & Home Technologies Inc.  •  Palazzo Owner’s Manual  •  4082-310 Rev. C  •  11/15 

B. Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.  If you do 

experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and 

the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.  Contact 

your dealer to arrange a service call by a qualified service technician.

IntelliFire™ Ignition System

Symptom

Possible Cause

Corrective Action

1. Pilot won’t light. 

The ignitor/module 

makes noise, but no 

spark.

A.  Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are 

connected to correct terminals on module and pilot assembly.

B.  Loose connections or electrical 

shorts in the wiring.

Verify no loose connections or electrical shorts in wiring from mod-

ule to pilot assembly. Verify connections underneath pilot assembly 

are tight; also verify igniter and flame sense wires are not grounding 

out to metal chassis, pilot burner, pilot enclosure, mesh screen if 

present, or any other metal object. 

C.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 

approximately .17 in. or 1/8 in. (3 mm).

2. Pilot won’t light, 

there is no noise or 

spark.

                                                     

A.  No power, transformer installed 

incorrectly.

Verify that transformer is installed and plugged into module. Check 

voltage of transformer at connection to module. Acceptable read-

ings of a good transformer are between 3.2 and 2.8 volts AC.  

B.  A shorted or loose connection in 

wiring configuration or wiring har-

ness.

Remove and reinstall the wiring harness that plugs into module. 

Verify there is a tight fit. Verify pilot assembly wiring to module. Re-

move and verify continuity of each wire in wiring harness.  Replace 

any damaged components.

C.  Junction Box Wiring

Verify that 110-120 VAC power is “ON” to junction box.

D.  Module not grounded.

Verify black ground wire from module wire harness is grounded to 

metal chassis of appliance.

3. Pilot sparks, but 

Pilot will not light.

A.  Gas supply.

Verify  that  incoming  gas  line  ball  valve  is  “open”.  Verify  that  inlet 

pressure reading is within acceptable limits.

B.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 

approximately .17 in. or 1/8 in. (3 mm).

C.  Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

D.  Pilot valve solenoid. 

Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module.  

If below 1.5 volts, replace module.  If 1.5 volts or greater, replace 

valve.

Содержание ODPALG-48

Страница 1: ... gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing ...

Страница 2: ...Product Specific Information A Appliance Certification 6 B BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Before Lighting Appliance 8 E Lighting Instructions IPI 9 F Appliance Break In 10 G Wall Control 10 4 Maintenance and Service A Maintenance Frequency and Tasks 11 B Maintenance Tasks Homeowner 11 C Ma...

Страница 3: ...___________________________ Serial Number ___________________________________________ Date Installed ___________________________ Appliance Information Local Dealer Information Dealer Fill in your name address phone and email information here and appliance information below Dealer Name ________________________________________________________ Address _________________________________________________...

Страница 4: ... This warranty only covers Products that are purchased through an HHT authorized dealer or distributor A list of HHT authorized dealers is available on the HHT branded websites This warranty is only valid while the Product remains at the site of original installation Contact your installing dealer for warranty service If the installing dealer is unable to provide necessary parts contact the neares...

Страница 5: ...f The Product has been over fired or operated in atmospheres contaminated by chlorine fluorine or other damaging chemicals Over firing can be identified by but not limited to warped plates or tubes rust colored cast iron bubbling cracking and discoloration of steel or enamel finishes and cracking or spalling of refractory or cementitious materials The Product is subjected to prolonged periods of d...

Страница 6: ...pliances for Use at High Altitudes MODELS ODPALG 48 ODPALGST 48 LABORATORY Underwriters Laboratories Inc UL TYPE Outdoor Decorative Gas Appliances STANDARD ANSI Z21 97 2014 CSA 2 41 2014 When an appliance is for connection to a fixed piping sys tem the installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or International Fu...

Страница 7: ...hildren away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Clothing furniture draperies and other flammable materials must not be placed on or near the appliance To prevent unintended operation when not using your fireplace for an extended period of time winter mont...

Страница 8: ...ppliance and the section of this manual in which they are discussed WARNING Risk of Fire or Explosion Appliance must be set up for compatible gas type This appliance is designed to operate on either natural gas or propane Make sure the appliance is compatible with gas type selected for installation site Conversions must be made by a qualified service technician using Hearth Home Technologies speci...

Страница 9: ...T try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 VAC TO THE CONTROL VALVE Improper installation adjustment al teration service or maintenance can cause injury or property damage Re fer to the owner s information manual provided with this appliance This appliance needs fresh air for safe operation...

Страница 10: ...f B Toggles the BLUE appliance lighting On Off Figure 3 3 Wall Control WARNING DO NOT place combustible objects in front of the fireplace High temperatures could start a fire WARNING Risk of Fire or Burns Provide adequate clearance for service access Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies F Appliance Break In Initial Break in P...

Страница 11: ...g must be replaced prior to operating the fireplace Installation and repair should be done by a qualified service technician only The appliance should be inspected before use and at least annually by a professional service person 4 Maintenance and Service Task Frequency To be completed by Weather Cover Power Screen Annually Homeowner Wall Control Seasonally Burner Ignition Operation Annually Quali...

Страница 12: ...ls and adhesives used around the fireplace Metallic noise Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the fireplace Wall above appliance feels hot to the touch No action necessary This appliance ships with a non combustible material Specifications...

Страница 13: ... Verify gap of igniter to right side of pilot hood The gap should be approximately 17 in or 1 8 in 3 mm 2 Pilot won t light there is no noise or spark A No power transformer installed incorrectly Verify that transformer is installed and plugged into module Check voltage of transformer at connection to module Acceptable read ings of a good transformer are between 3 2 and 2 8 volts AC B A shorted or...

Страница 14: ...ilot orifice is installed and gas inlet is set to pressure specifications Check pilot for soot Clean if necessary C Module is not grounded Verify module is securely grounded to metal chassis of appliance Verify that wire harness is firmly connected to the module D Damaged pilot assembly or contaminated flame sensing rod Verify that ceramic insulator around the flame sensing rod is not cracked dama...

Страница 15: ... the appliance Ensure that both the 3V IPI control module power supply as well as the 12V screen and LED power supply are securely plugged into the appliance junction box Faulty Wiring Check appliance for loose corroded connections or shorted wires LED Failure Check for 12VDC on white and tan wires going to LED harness If 12VDC is present LED strip is bad Power Supply failure Check for 12VDC where...

Страница 16: ...ect main power to ap pliance before performing any maintenance 2 Place a flat screwdriver between the front face and screen of the appliance at outside corners locate the two slots 3 Gently pry up on both lower corners of the screen to disengage the screen front from screen frame assem bly See Fig 5 1 4 Pull top of screen front away from appliance and lift to remove See Fig 5 2 Set screen front an...

Страница 17: ...e for the Palazzo series outdoor gas appliance See your dealer for more information Optional Media Kits CAUTION Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional acces sories with this appliance Using non listed accessories could result in a safety hazard and will void warranty Media Kits Media Ebony 48 Media Cobalt 48 Media Red 48 Media Amber 48 ...

Страница 18: ...umber when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Top Standoff Qty 2 req SRV4082 195 2 Sheild Pilot SRV4082 174 3 Hearth Pan Assembly SRV4082 019 4 Lower Face Assembly SRV4082 025 5 Screen Front SRV4082 240 6 Screen SRV4082 241 Y 7 Support Frame Assembly SRV4082 040 8 Valve Assembly See Following Pages 9 Burner Assembly See...

Страница 19: ...ulkhead Flexible 4021 428 Y 8 3 Male Connector 303 315 8 4 Valve Fixed NG 593 500 Y Valve Fixed LP 593 501 Y 8 5 Valve Bracket Upper SRV4082 210 8 6 Control Module 593 592 Y 8 7 Front Panel SRV4082 207 8 8 5A Power Supply SRV4082 315 Y 8 9 Junction Box Assembly SRV4082 023 Y 8 10 Linear Actuator SRV4082 320 Y 8 11 Quick Release Pin SRV4082 336 8 12 Actuator Bracket SRV4082 177 8 13 12 Flex Ball As...

Страница 20: ...rial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 9 1 Burner Tube SRV4082 322 Y 9 2 Pilot Burner Bracket SRV4082 169 9 3 Burner Bracket Qty 2 req SRV4082 170 9 4 Burner Shield SRV4082 211 14 Switch Box Assembly SRV4082 041 Y 14 1 Rock Template SRV4082 377 14 2 Switch Panel Assembly SRV4082 367 14 3 Trim Ring SRV4082 378...

Страница 21: ...tocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Top Standoff Qty 2 req SRV4082 195 2 Sheild Pilot SRV4082 174 3 Hearth Pan Assembly SRV4082 019 4 Lower Face Assembly Qty 2 req SRV4082 025 5 Screen Front Qty 2 req SRV4082 240 6 Screen Qty 2 req SRV4082 241 Y 7 Support Frame Assembly Qty 2 req SRV4082 040 8 Valve Assembly See Following Pages 9 Burner Assembly See Following Pages 10 Glass Pan...

Страница 22: ...Bulkhead Flexible 4021 428 Y 8 3 Male Connector 303 315 8 4 Valve Fixed NG 593 500 Y Valve Fixed LP 593 501 Y 8 5 Valve Bracket Upper SRV4082 210 8 6 Control Module 593 592 Y 8 7 Front Panel SRV4082 207 8 8 5A Power Supply SRV4082 315 Y 8 9 Junction Box Assembly SRV4082 023 Y 8 10 Linear Actuator SRV4082 320 Y 8 11 Quick Release Pin SRV4082 336 8 12 Actuator Bracket SRV4082 177 8 13 12 Flex Ball A...

Страница 23: ...erial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 9 1 Burner Tube SRV4082 322 Y 9 2 Pilot Burner Bracket SRV4082 169 9 3 Burner Bracket Qty 2 req SRV4082 170 9 4 Burner Shield SRV4082 211 14 Switch Box Assembly SRV4082 041 Y 14 1 Rock Template SRV4082 377 14 2 Switch Panel Assembly SRV4082 367 14 3 Trim Ring SRV4082 37...

Страница 24: ...______________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ DO NO...

Отзывы: