15
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Courtyard Owner’s Manual • 4608-900 Rev. F • 01/19
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Appliance does not
turn on when Control
Panel on/off switch is
depressed
No AC power to
appliance
Check that GFCI breaker is operating as intended and is
not tripped. Verify that AC power has been connected to
the appliance. Ensure that the 3V IPI control module power
supply are securely plugged into the appliance junction box.
Faulty Wiring
Check appliance for loose/corroded connections or shorted
wires.
Control Panel Failure Replace Control Panel
C. Troubleshooting – Control Panel
D. Engine Access
Cover Screws
Valve
Control
Module
Junction
Box
Injector
Burner
Tube
Figure 5.1.