background image

 

Page | 10                   

www.outdoorrooms.com

   

 

BCH-1242 42477 REV A 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D. Leak Check and Line Purge 

 

Once the gas piping system is in place, all fittings and 
connections need to be checked for leaks.  

 

Use a commercially available, non-corrosive leak-
check solution. 

 

Once leak test is complete, be sure to rinse off all 
remaining leak-check solution from the gas piping 
system. 

 

WARNING: CHECK FOR GAS LEAKS 

FIRE RISK 
EXPLOSION RISK 
ASPHYXIATION RISK 

 

Check all fittings and connections. 

 

Do not use an open flame. 

 

Eliminate possible ignition sources such as open 
flames and sparks during leak check. 

 

Presence of gas leaks can lead to high levels of 
carbon monoxide. If leaks are detected, ensure 
proper ventilation is available to expedite the 
dissipation of leaked gas. 

 

 

After leak check has been performed and the gas 
supply system is leak-free, a purge of the air in the 
supply line should be performed in order to ensure a 
safe first ignition of the appliance.  

 

 

WARNING:  

FIRE RISK 
EXPLOSION RISK 

 

Gas build-up during purge may ignite. 

 

Purge should be performed by an authorized gas 
technician. 

 

Eliminate possible ignition sources such as open 
flames and sparks during leak check. 

 

Ensure adequate ventilation. 

 

E. Additional Gas Supply 
Information 

For LP installations using a non-disposable, self-
contained LP-gas supply system (20 lb. LP tank and the 
manufacturer supplied regulator hose): 

 

The LP- gas cylinder used with this appliance 
must be constructed and marked in 
accordance with the U.S. Department of 
Transportation. (D.O.T.) 

Specifications for LP-

Gas Cylinders, 

or the 

Standard for Cylinders, 

Spheres and Tubes for Transportation of 
Dangerous Goods and Commission, 

CAN/CSA-

B339, as applicable.

 

 

The LP-gas cylinder must be provided with a 
listed overfilling prevention device (OPD).

 

 

The LP-gas cylinder must be compatible with 
the regulator hose supplied by the 
manufacturer with this appliance.

 

 

WARNING 

Improper installation, adjustment, alteration, 
service or maintenance can cause injury or 
property damage. Read the installation, 
operating, and maintenance instructions 
thoroughly before installing or servicing this 
equipment. 

 

 

WARNING 

Installation and repair should be performed 
only by a qualified service technician. 

Содержание BCH-1242

Страница 1: ...and liquids in the vicinity of this or any other gas appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other gas appliance DANGER CARBON MONOXIDE HAZAR...

Страница 2: ...30 lb capacity or less Do not use store or transport cylinder where it would be exposed to high temperatures Relief valve may open allowing a large amount of flammable gas to escape When transporting...

Страница 3: ...ency As the owner of an Outdoor GreatRoom Company Boreal Complete Heat you ll want to read and carefully follow all of the instructions contained in this owner s manual Pay special attention to all ca...

Страница 4: ...d Line Purge 10 E Additional Gas Supply Information 10 5 Installation 11 A Electrical Connections 11 B Gas Connection for Fixed Fuel Piping Systems Manual Ignition 12 C Gas Connection for Fixed Fuel P...

Страница 5: ...014 The Boreal Complete Heat and Boreal Complete Heat with Direct Spark Ignition have been tested in accordance with ANSI Z21 97 2014 and CSA 2 41 2014 for Canada and has been listed by Underwriters L...

Страница 6: ...fety glasses during installation WARNING Do NOT burn solid fuels in this gas appliance WARNING Inspect appliance and components for damage Damaged parts may impair safe operation Do NOT install damage...

Страница 7: ...ation NEVER install a damaged component Report any damage to the manufacturer Review the Limited One Year Warranty information found at the end of this manual and the warnings on Page 6 E Included Ite...

Страница 8: ...tive than the following configurations Walls on all four sides with no overhead cover A partial enclosure with an overhead cover and two side walls walls can be parallel or at right angles to each oth...

Страница 9: ...tant and should be performed only by a qualified gas professional Supply line sizing requirements need to be made following ANSI Z223 1 NFPA 54 Pressure requirements for the appliance are shown in the...

Страница 10: ...ge may ignite Purge should be performed by an authorized gas technician Eliminate possible ignition sources such as open flames and sparks during leak check Ensure adequate ventilation E Additional Ga...

Страница 11: ...IGNITION CONNECTION If the Boreal Complete Heat was ordered with the Crystal Fire Direct Spark Ignition System CF DSI the 110VAC 3VDC power adaptor should already be connected to the internal GFCI out...

Страница 12: ...n the adaptor Image 5 6 5 Open the dedicated shutoff valve for the appliance and apply non corrosive leak check solution to the connection between the flex line and the fixed pipe system Clean off res...

Страница 13: ...h on the flare nut and one wrench on the adaptor Image 5 9 5 Open the dedicated shutoff valve for the appliance and apply non corrosive leak check solution to the connection between the flex line and...

Страница 14: ...Open the valve on the LP tank and apply non corrosive leak check solution to the connection between the regulator hose and the LP tank Clean off residual leak check solution 5 If no leaks are present...

Страница 15: ...the Outdoor GreatRoom Company This ensures that the proper amount of media is used and that the media is approved for use in gas appliances MEDIA MUST BE IN PLACE DURING OPERATION Operation of applia...

Страница 16: ...f ignition does not occur within 15 seconds turn control valve to OFF position and wait 5 minutes before attempting ignition again This allows gas to dissipate 5 To extinguish turn control valve to OF...

Страница 17: ...uld occur within 5 seconds Image 6 6 If ignition takes longer than 12 seconds the system will shut down If system does not achieve ignition turn switch to OFF and wait 5 minutes before reattempting ig...

Страница 18: ...e 6 9 It is not necessary to have fan operating while the burner is operating however it is highly recommended to use the fan to cool the decorative heat exchanger tubes when the burner is shut down C...

Страница 19: ...normal it is not rust Image 6 10 Some soot build up on the tubes is normal and more soot build up will occur with the use of LP than with natural gas Soot build up can be removed with a damp cloth Ima...

Страница 20: ...D Light Kit do not turn on A 115 VAC power source has failed Ensure that external power cord is connected to appliance Check connection to power source B GFCI outlet within appliance has been tripped...

Страница 21: ...g sound but no visible spark is produced A Gap between sparker electrode and ground electrode is too great Ensure that the gap between sparking electrode and ground electrode is B Excessive media buil...

Страница 22: ...ermine if any blockage or obstruction is present b Use compressed air to clear obstructions out of the outlet vents Image 8 1 2 Inspect burner surface for damage and debris a Remove glass media Image...

Страница 23: ...ld turn off c Press the RESET button of the GFCI outlet and the fan should turn back on Image 8 7 d If GFCI outlet fails to operate in this manner replace the GFCI outlet with the manufacturer s sugge...

Страница 24: ...LP Manual Ignition 38 38 ORIFICE 10 Orifice for NG Manual Ignition 17 17 ORIFICE 11 Orifice for LP with Optional DSI System 1 8 1 8 ORIFICE 12 Orifice for NG with Optional DSI System 7 7 ORIFICE 13 M...

Страница 25: ...EUTRAL GROUND 115 VAC CIRCUIT OPTIONAL CF DSI CIRCUIT CONTROL VALVE CONTROL MODULE TRANSFORMER CONNECTED TO GFCI CONTROL SWITCH IGNITER SENSOR 3 3 VDC 3 3 VDC 115 VAC OPTIONAL LED LIGHT KIT CIRCUIT 12...

Страница 26: ...f the Product or any component has been removed repaired or replaced before OGC has been afforded a reasonable opportunity to inspect the Product This warranty is limited to the replacement or repair...

Отзывы: