background image

Operation

 

900-0138-01-00 Rev

 A 

13

 

 

Figure 8  Data Log Example for the System 

 

 

Figure 9  Data Log Example for the Charge Controller 

 

FTP Access to Logs 

A file transfer protocol (FTP) site such as FileZilla may be used to connect to the AXS Port.  The FTP 
client presents a normal file explorer display of the files stored on the microSD card. 

The log files are stored under the LOGFILES directory.  The naming convention of the log files is the 
same as noted above.  

Firmware Updates 

The firmware revision of the AXS Port can be updated directly using a microSD card, or it can be 
updated using an FTP site and the microSD card. 

To update the firmware directly: 

1.

 

If necessary, load a firmware update to the microSD card.  These updates are available at the 
OutBack website, www.outbackpower.com. 

2.

 

Insert the SD card into the slot on the AXS Port.  

3.

 

Disconnect any OutBack device cable from the AXS Port. 

4.

 

Using a narrow tool, press and hold the reset switch.  Reconnect the OutBack device cable.  The 
amber SD Card LED will blink while the firmware is being updated.  When this indicator stops 
blinking, release the switch. 

 

 

Date AH 

Kwh 

Max 
Amps

Max 
Watts

Absorb 
Time 

Float 
Time 

Min  
Battery V 

Max  
Battery V 

MAX 
VOC 

6/13/11 

1.2 

29 

 0:00 

 0:00 

24.1 

29.1 

122 

6/12/11 

38 

0.9 

5.5 

143 

 0:00 

 0:00 

24.1 

29 

122 

6/11/11 

32 

0.8 

5.6 

144 

 0:00 

 0:00 

24.1 

28.7 

120 

NOTE:

  This header line is included in the download. 

Da

te 

Time 

Port 

Device t

ype

 

Invrt 

current 

Chrg 

current 

Buy current 

Ac inpu

voltage 

Ac output 

voltage 

Sell curren

Operatin

mode 

Error mode 

Ac mode 

Battery 

voltage 

Misc 

Warning 

mode 

6/09/11 

17:28:20 

2  2  0 0 0 230 

0 2 0 0 

500 

25 

6/09/11 

17:28:20 

2  2  0 0 0 230 

0 2 0 0 

508 

25 

6/09/11 

17:28:20 

2  2  0 0 0 230 

0 2 0 0 

508 

25 

 

NOTE:

  This header line is NOT included in the download. 

Содержание AXS Port

Страница 1: ...e directamente a un solo dispositivo o a varios por medio de los componentes de administraci n de comunicaciones HUB4 o HUB10 de OutBack La AXS Port permite crear interfaces de usuario a medida para s...

Страница 2: ...NTP Puertos HUB Dispositivo RJ 45 Comunicaciones RJ 45 Sensor de temperatura RJ 11 Protocolo de comunicaci n Modbus TCP seg n est ndar SunSpec Interfaz de dispositivo de OutBack Exclusivo de OutBack...

Страница 3: ...AXS Port SunSpec Modbus Interface Owner s Manual...

Страница 4: ...Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING OUTBACK POWER TECHNOLOGIES a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS M...

Страница 5: ...Card Logging 12 Data Log File Format 12 FTP Access to Logs 13 Firmware Updates 13 Email Functions 14 Troubleshooting 15 Basic Troubleshooting 15 Error Codes 15 Specifications 17 Regulatory Specificati...

Страница 6: ...igure 1 Features 3 Figure 2 Wall Mount 5 Figure 3 DIN Rail Mount 5 Figure 4 Cabling 6 Figure 5 Accessories 6 Figure 6 LED Indicators 7 Figure 7 Reset Switch 7 Figure 8 Data Log Example for the System...

Страница 7: ...tBack products NOTE This product is for use instead of a system display such as the MATE3 OutBack does not support the use of the AXS Port and a system display at the same time Audience This manual is...

Страница 8: ...rmware updates The AXS Port can be equipped with a clip for mounting on a DIN rail This clip is included The AXS Port can be equipped with an additional temperature sensor to supplement the battery se...

Страница 9: ...rail Hook the upper edge of the clip over the DIN rail 3 Press on the lower edge to bend it Slide the clip over the DIN rail and snap into place Release the clip once the device is securely in place...

Страница 10: ...D Card LED will illuminate See Figure 6 Micro SD Card Slot Temperature Sensor Port NOTE Orient the microSD card with the conductors facing down The angled corner enters on the right of the slot OutBac...

Страница 11: ...et switch is recessed to avoid being accidentally pressed Insert a paper clip wire or similar narrow tool The switch should be held for five seconds The Fault LED will blink during the resetting proce...

Страница 12: ...f field data or a fixed value where applicable Description Describes the field data SunSpec Block Structure The first block is the Common Block which supplies vendor and model information for the devi...

Страница 13: ...W OutBack_Status_Email_To _Address_2 String 40 N A N A Programmable Status Email to Address 2 165 165 1 R W OutBack_Alarm_Email_ Enable uint16 Enumerated N A Programmable 0 Disabled 1 Enabled 166 190...

Страница 14: ...Volts N A Measured Highest VOC today 18 18 1 R CC_Todays_kWH uint16 KWH KWH _SF Measured Daily accumulated kilowatt hours output 19 19 1 R CC_Todays_AH uint16 AH AH_SF Measured Daily accumulated amp...

Страница 15: ...config_Wakeup_VOC uint16 Volts Voltage _SF Programmable Voc change which causes Wakeup occurs 29 29 1 R W CCconfig_Snooze_Mode_ Amps uint16 Amps Voltage _SF Programmable Snooze Mode Amps 30 30 1 R W C...

Страница 16: ...nt16 Mins N A Read Only Data Log Float Time Minutes 61 61 1 R CCconfig_Data_Log_Daily_ Min_Batt_Volts uint16 Volts Voltage _SF Read Only Data Log minimum daily battery voltage 62 62 1 R CCconfig_Data_...

Страница 17: ...nsert the SD card into the slot on the AXS Port 3 Disconnect any OutBack device cable from the AXS Port 4 Using a narrow tool press and hold the reset switch Reconnect the OutBack device cable The amb...

Страница 18: ...age 8 Table 4 Email Setup Field Value OutBack_SMTP_Server_Name Email account name such as outbackpower com OutBack_SMTP_Account_Name Name of SMTP server for sending mail such as smtp gmail com OutBack...

Страница 19: ...ve card Insert the card firmly or replace the card Fault LED illuminates OutBack_error field in OutBack block is occupied by an error code Check for error codes Time based functions are incorrect foll...

Страница 20: ...Troubleshooting 16 900 0138 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 21: ...c standard OutBack Device Interface OutBack Proprietary PC Interface 10 100 Ethernet Mounting DIN clip provided or surface mounting Environmental Rating Indoor Type 1 IP 30 non condensing AXS Port 40...

Страница 22: ...North America 5917 195th St NE Arlington WA 98223 USA 1 360 435 6030 900 0138 01 00 Rev A...

Отзывы: