Operation
900-0248-01-00 Rev A
33
Table 5
General Settings
Item Description
2 9
C O v
2 1. 0
4 2 . 0
Low battery cut-out voltage. This is the low battery voltage setting which shuts down the inverter. This is
settable when item
0 5
is set to
U S E
.
NOTE
: This item shuts down only the inverting function. If this function shuts down due to low battery
cut-out, the charger, transfer, and other functions will still work, as will the display.
Selection range (model TL3024E): 25.0 to 31.5 Vdc
Selection range (model TL5048E): 48.0 to 61.0 Vdc
3 0
E E N
Equalization function. (See page 28.) Selections:
E E N
(Equalize enabled),
E d S
(Equalize disabled).
Allows equalization to take place automatically. This item is settable when item
0 5
is set to either
F L d
or
U S E
.
3 1
E v
2 9 . 2
5 8 . 4
Equalization charging voltage. This is the setting for equalization once enabled in item
3 0
or item
3 6
.
(See page 28.)
Selection range (model TL3024E): 25.0 to 31.5 Vdc
Selection range (model TL5048E): 48.0 to 61.0 Vdc
3 3
6 0
Equalization time. This timer begins running once item
3 1
is reached. (See page 28.)
Selection range: 5 to 900 minutes.
3 4
1 2 0
Equalization timeout. The maximum time permitted for equalization. (See page 28.)
Selection range: 5 to 900 minutes.
3 5
3 0 d
Equalization interval. The days between automatic equalization cycles. (See page 28.)
Selection range: 0 to 90 days.
3 6
A d S
Immediate equalization. The main display reads
E q
. (See page 28.) Selections:
A E N
(Enabled),
A d S
(Disabled).
This is usable when 30 is set to
E E N
.
If
A d S
is selected, it will cancel equalization until the next automatic cycle based on item
3 5
.
3 7
N r t
Reset
PV accumulation kWh data.
Selections:
N r t
(Not reset),
r S t
(Reset).
9 3
N r t
Erase data log (all accumulated data). Selections:
N r t
(Not reset),
r S t
(Reset).
9 4
1 0
Data log storage period. During this period, the Alino logs 1000 status items (voltage readings, etc.) for
analysis. The resulting data is more general if taken across a wider time period. It is more specific if taken
across a narrower period. Selection range: 3 to 60 days.
9 5
n I N
Time (minute) setting. Selection range: 00 to 59.
9 6
H O U
Time (hour) setting. This product uses a 24-hour clock. Selection range: 00 to 23.
9 7
d A Y
Date (day) setting. Selection range: 00 to 31.
9 8
N o n
Date (month) setting. Selection range: 00 to 12.
9 9
y E A
Date (year) setting. Only two digits are used. Selection range: 17 (2017) to 99 (2099).
Содержание Alino TL Series
Страница 1: ...Alino TL Power Conditioning Unit Owner s Manual...
Страница 45: ...Specifications 900 0248 01 00 Rev A 45 This page intentionally left blank...
Страница 46: ...Specifications 46 900 0248 01 00 Rev A This page intentionally left blank...
Страница 47: ...Specifications 900 0248 01 00 Rev A 47 This page intentionally left blank...