28
• Close the panel.
Notes:
• All wires of indoor and outdoor unit should be connected by a qualified person.
• If the length of power connection wire is insufficient, please contact your dealer for a new one.
Do not extend the wire by yourself.
• A circuit break must be installed in the line. The air switch should be all-pole parting and the contact
parting distance should be more than 3 mm.
Step 8: Bind up pipes
• Bind up the connection pipe, power cord and drain hose with the band.
• Reserve a certain length of drain hose and power cord for installation when binding them.
When binding to a certain degree, separate the indoor power and then separate the drain hose.
• Bind them evenly.
• The liquid pipe and gas pipe should be bound separately at the end.
Notes:
• The power cord and control wire cannot be crossed or winded.
• The drain hose should be bound at the bottom.
Step 9: Hang the indoor unit
• Put the bound pipes in the wall pipe and then make them pass through the wall hole.
• Hang the indoor unit on the wall-mounting frame.
• Stuff the gap between pipes and wall hole with sealing gum.
• Fix the wall pipe.
• Check if the indoor unit is installed firmly to the wall.
Note:
connection
pipe
drain hose
band
indoor power cord
indoor unit
gas
pipe
indoor and outdoor
power cord
band
drain hose
liquid pipe