background image

16

MALFUNCTION

MALFUNCTION ANALYSIS

Please check below items before asking for servicing. If the malfunction still cannot be eliminated, please 

contact a qualified person. 

Phenomenon

Items to check

Solution

Indoor unit cannot

receive remote

control signal or

remote control does  

not work.

Is there severe interferences (such as 

static electricity, unstable voltage)?

Cut the power supply off and put the 

power back after about 3 minutes, 

and then turn on the unit again.

Is the remote control within the 

signal receiving distance?

Signal receiving distance is  

26.25 ft. (8 m).

Is there any obstacle between the 

unit and the remote control?

Remove obstacles.

Is the remote control pointing at the 

receiving window of the indoor unit?

Select proper angle and point

the remote control at the receiving 

window on indoor unit.

Is the remote control display fuzzy  

or there is no display at all ?

Check the batteries. If the  

battery charge level is too low, 

please replace them.

No display when operating

the remote control?

Check if remote control is damaged. 

If so, replace it.

Are there fluorescent lamps in the 

room?

Bring the remote control

close to the indoor unit.

Turn off the fluorescent lamps

and then try it again.

No air flow

from indoor unit.

Are air inlet or air outlet of indoor 

unit blocked?

Eliminate obstacles.

Under heating mode, has indoor

temperature reached set

temperature?

After reaching set temperature,

indoor unit will stop blowing out air.

Has the heating mode been

just turned on?

In heating mode, in order to prevent 

blowing out cold air, indoor unit will 

start a few minutes after the unit has 

been turned on, which is normal.

Appliance cannot 

operate.

Is there a power failure?

Wait until power resumes.

Circuit break trips off?

Ask a qualified person to replace 

circuit break or replace wiring.

Has the unit been turned on imme-

diately after being turned off?

Wait for 3 minutes, and then turn on 

the unit again.

Are the function setting on the 

remote control correct?

Reset the functions

Содержание ELD09KCH15S

Страница 1: ...d keep it for future reference DUCTLESS SINGLE ZONE HEAT PUMP INS529 201701 00 Owner s Manual 15 SEER INVERTER 9 000 to 24 000 BTU hr Models Heating and Cooling ELD09KCH15S ELD12KCH15S ELD18KCH15S ELD...

Страница 2: ...installing and relocating the unit 20 Tools required for installation 21 Selection of installation location 21 Requirements for electrical connection 22 Installation 23 Installation of indoor unit 23...

Страница 3: ...on that if not avoided could result in serious injury or death Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related inf...

Страница 4: ...re hazard Maintenance must be performed by qualified person Otherwise it may cause personal injury or damage Do not repair the appliance by yourself It may cause electric shock or damage Please contac...

Страница 5: ...related to electricity and safety Do not turn the power on before finishing installation If the supply cord is damaged it must be replaced by a qualified person in order to avoid problems The tempera...

Страница 6: ...ls or plants If it is unavoidable please add a fence around the outdoor unit for safety purpose Instructions for installation and use of this product are provided by the manufacturer WORKING TEMPERATU...

Страница 7: ...e different from below graphics please refer to actual product for reference purposes Indoor unit Remote Control Outdoor unit NOTICE Panel Filter Air outlet Air inlet Horizontal louvre AUX button Air...

Страница 8: ...Actual product may be different from below graphics please refer to actual product for reference purposes NOTICE Cooling indicator Heating indicator Temperature indicator Drying indicator Power indic...

Страница 9: ...6 SLEEP Lowering or raising the temperature gradual ly during the night 7 TIMER Set starting and ending time 1 3 4 2 6 3 7 5 ICON IDENTIFICATION ON REMOTE CONTROL DISPLAY Swing operation Sending signa...

Страница 10: ...elect automatic mode the device automatically selects the appropriate function to main tain temperature between 20 C and 25 C In this mode temperature can t be changed or displayed on remote control C...

Страница 11: ...isappears 7 TIMER button This timer function allows you to program the unit while determining when it starts and when it ends When unit is off press this button to set TIMER ON T ON and H icon will be...

Страница 12: ...ry batteries and make sure the position of and is correct as illustrated 4 Put back the cover as illustrated NOTES During operation point the remote control at the receiving window on the indoor unit...

Страница 13: ...AUX button to turn on or turn off the appliance As illustrated open the panel press the AUX button to turn on or turn off the device When it is turned on it will operate under AUTO mode Use insulated...

Страница 14: ...ain angle as illus trated less than 60 do not force the panel 3 Clean filter Use a vacuum or water to clean the filter When the filter is very dirty use water below 45 C to clean it and then put it in...

Страница 15: ...blocked Checking after usage 1 Disconnect power supply 2 Clean filters and indoor unit panel 3 Check whether mounting bracket for outdoor unit is damaged or corroded If so please contact the dealer No...

Страница 16: ...tteries If the battery charge level is too low please replace them No display when operating the remote control Check if remote control is damaged If so replace it Are there fluorescent lamps in the r...

Страница 17: ...ow Wait until the voltage comes back to normal Is filter dirty Clean the filter Is the set temperature in proper range Adjust temperature within proper range Are doors and windows open Close doors and...

Страница 18: ...r code remains please contact a qualified person for service F1 Please contact a qualified person for service F2 Please contact a qualified person for service H1 This code indicates that device is in...

Страница 19: ...wall Space to the wall At least 15 cm At least 15 cm At least 250 cm Space to the floor At least 300 cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the obstruct...

Страница 20: ...or rupture resulting in injury During refrigerant recovery make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor start...

Страница 21: ...A place near coastal regions A place with oil or fumes in the air A place with sulphurous gas Other places with special environment In a laundry room near a bath shower or swimming pool Indoor unit Th...

Страница 22: ...utral wire and grounding wire Cut off the power supply before proceeding any work related to electricity Do not put through the power before finishing installation If the supply cord is damaged it mus...

Страница 23: ...mly installed by pulling the frame If a plastic anchor is loose drill another fixing hole nearby Step 3 Open piping hole Choose the position of piping hole according to the direction of outlet pipe Th...

Страница 24: ...Wrap the indoor pipe and joint of connection pipe with insulating pipe and then wrap it with tape Step 6 Install drain hose Connect the drain hose to the outlet pipe of indoor unit cut off the hole r...

Страница 25: ...onnect the power connection wire to the wiring terminal according to the color tighten the screw and then fix the power connection wire with wire clip After finishing wiring clamp the grounding wire y...

Страница 26: ...nd then separate the drain hose Bind them evenly The liquid pipe and gas pipe should be bound separately at the end Notes The power cord and control wire cannot be crossed or winded The drain hose sho...

Страница 27: ...nit should be installed at least 3 cm above the floor in order to install drain joint Expansion screws needed per type of unit Cooling capacity BTU hr W No Number of screws 9000 2637 6 12000 3516 6 18...

Страница 28: ...ion nut with torque wrench by referring to the sheet below Step 5 Wiring of the unit Remove the wire clip connect the power connection wire and signal control wire to the wiring terminal according to...

Страница 29: ...nimum bending semi diameter is 10 cm If the outdoor unit is higher than the wall hole you must set a U shaped curve in the pipe before pipe goes into the house in order to prevent rain from getting in...

Страница 30: ...ains at 0 1 MPa If the pressure decreases there may be leakage Open the liquid valve and gas valve completely with inner hexagon spanner and remove the manometer Tighten the screw caps of valves and r...

Страница 31: ...plate It may cause malfunction or damaging the parts Are electric wiring and pipes installed correctly It may cause malfunction or damaging the parts Is the unit grounded securely It may cause electri...

Страница 32: ...e ambient temperature is lower than 16 C the appliance will not work in COOL cooling mode 3 Operating pressure test In COOL or HEAT mode set the temperature to the maximum set point 30 C or 86 F Set t...

Страница 33: ...ection pipe is prolonged for 33 ft 10 m at the basis of standard length you should add 5 ml of refrigerant for each additional 16 ft 5 m of connection pipe The calculation method of additional refrige...

Страница 34: ...Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe pipe pipe cutter leaning uneven burr pipe shaper downwards union pipe pipe 5 Expand the port Expa...

Отзывы: