14
6.4 Battery-fuse
For protection of all electronics a main-fuse is put in series with the batteries.
The fuse-holder is placed as an interconnection between the batteries
In case of standard 130 kg lift a 20A blade fuse is needed.
6.5 Sleepmode
When the lift has not been charged for 1 or 8 hours it will go into a sleepmode.
In sleepmode, the current-consumption is approximately 10 mA.
If the lift is in the sleepmode, you can simply wake it up by controlling the armrest control left or
right. After waking up the lift can be used directly.
The time till sleepmode can be set by dipswitch 3.
6.6 Lift will not be used for a longer period.
When, for example, a user goes on vacation, we advise to keep the transformer connected to the mains
voltage.
In this situation the charging-circuit will keep the batteries in good condition.
Only switch off the armrest button.