6
Page
HIGH CURRENT SCHEMATIC
This schematic shows the high-current connections between the batteries and the motor.
MOTOR 1 and MOTOR 2 are the field winding. MOTOR 3 and MOTOR 4 are the
armature winding.
The Forward – Reverse switch swaps connections to the armature winding.
NOTE: The resistors shown are a fraction of an Ohm each and will measure zero Ohms
with the usual bench multimeter.
MOTOR 1
MOTOR 3
MOTOR 4
36V BATTERY
NEGATIVE
FORWARD
MOTOR 1 TO MOTOR 3,
AND MOTOR 4 TO BATTERY NEGATIVE
REVERSE
MOTOR 1 TO MOTOR 4,
AND MOTOR 3 TO BATTERY NEGATIVE
REVERSING
SWITCH
MOTOR 2
36V BATTERY
POSITIVE
LT LB
RT
RM
RB
SOLENOID HIGH
CURRENT
CONTACTS ARE
SHOWN AS
Red, From Internal Charger
Positive Output