background image

www.traxontechnologies.com | www.osram.us/traxon

©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS 
PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Installation Guide

V1.1 03/21

P. 3 of 24

SAFETY AND OPERATION

This installation guide uses the following special statement categories to alert you to key items:
1. 

WARNING -

 Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

2. 

CAUTION - 

Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.

3. 

NOTICE - 

Indicates information considered important for the proper operation of the product but not hazard 

related. 

4.  Please review this manual completely prior to beginning the installation process and take note of the 

following:

• 

The ProPoint luminaire and associated accessories must be installed by a qualified person in conjunction 

with all applicable electrical codes and standards.

• 

The ProPoint luminaire does not contain any user-serviceable parts. Opening of the luminaire will void the 

warranty.

• 

Do not use the product if the cables are damaged.

• 

Handle the luminaire carefully to prevent damage during installation. Rough handling may damage the 

internal electronics and void the warranty.

• 

Do not attempt installation in wet or severe weather conditions.

• 

Do not stare directly into the light beam while the unit is illuminated.

• 

IP66 rated. The ProPoint luminaire is not suitable for direct immersion in water.

• 

Do not operate the ProPoint luminaire without a connection to earth surface without a suitable earth 

connection (refer to local standards).

• 

The ProPoint luminaire is designed for operation at 120-277V AC (ETL)/220-240V AC (CE). Voltages 

outside of this range may damage the fixture and will void the warranty.

• 

The ProPoint luminaire housing may become hot during normal operation and present a risk of burn 

injury and fire hazard. Exercise caution when working in proximity to the luminaire and make sure that 
combustible material does not contact the housing or lens.

• 

Failure to keep the luminaire within the operating temperature range (-30°C to +55°C/-22°F to +131°F) will 

result in improper operation and will void the product warranty.

• 

Do not use harsh chemicals, cleaning solvents or strong detergents when cleaning the luminaire.

• 

Persons installing this product should make sure:

i. 

The installation complies with all applicable codes, state and local laws, ordinances, standards and 
safety regulations.

ii.  The installation environment is carefully studied and suitable surge protection measure(s) is taken. 

Suggested surge protection measures for outdoor application should reach “Live to Neutral” 5kV, 
“Live/Neutral to Earth” 10kV.

iii.  All luminaires can pass surge test up to “Live to Neutral” 1kV, “Live/Neutral to  Earth” 2kV according 

to EN61547 standard.

iv.  They are qualified or competent in the handling of electrical equipment.

Содержание Traxon ProPoint Sconce L

Страница 1: ...ProPoint Sconce INSTALLATION GUIDE V1 1 Cover ProPoint Sconce S ProPoint Sconce M ProPoint Sconce L...

Страница 2: ...ADEMARKS OF TRAXON TECHNOLOGIES U S PATENTS E U PATENTS JAPAN PATENTS OTHER PATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide V1 1 03 21 P 2 of 24 CONTENT 1 INTROD...

Страница 3: ...ere weather conditions Do not stare directly into the light beam while the unit is illuminated IP66 rated The ProPoint luminaire is not suitable for direct immersion in water Do not operate the ProPoi...

Страница 4: ...aditional and contemporary architectural environments Available in three sizes with both white and color options The daisy chain topology and direct wire nature of the fixture via the two integral cab...

Страница 5: ...3 21 P 5 of 24 1 3 Dimensions FIG 1 ProPoint Sconce S Tilt Adjustment Range Data Cable Length 72 00 in 1828 0 mm Data Cable Diameter 0 325 in 8 25 mm Power Cable Length 72 00 in 1828 0 mm Power Cable...

Страница 6: ...e V1 1 03 21 P 6 of 24 FIG 2 ProPoint Sconce M Data Cable Length 72 00 in 1828 0 mm Data Cable Diameter 0 325 in 8 25 mm Power Cable Length 72 00 in 1828 0 mm Power Cable Diameter 0 315 in 8 25 mm 0 3...

Страница 7: ...V1 1 03 21 P 7 of 24 FIG 3 ProPoint Sconce L 6mm hex key required to adjust fixture angle available from Traxon Data Cable Length 72 00 in 1828 0 mm Data Cable Diameter 0 325 in 8 25 mm Power Cable L...

Страница 8: ...minal Power Factor Input Voltage Range Operating Temperature Minimum Starting Temperature S 1 36 kg 3 00 lbs 9W Max 0 9 120 277VAC 50 60 Hz 30 C to 55 C 22 F to 131 F 20 C 4 F M 1 71 kg 3 77 lbs 15W M...

Страница 9: ...70A 105A n 35A 0 05ms Description In rush current 230V Description 1 Fixture 2 Fixtures 3 Fixtures n Fixtures Present time ProPoint Sconce S 22A 44A 66A n 22A 0 05ms ProPoint Sconce M 36A 72A 108A n...

Страница 10: ...on Remove the ProPoint Sconce luminaire from the packaging and place the unit on a level surface Bracket Preparation and Mounting CAUTION It is the installer s responsibility to ensure that the mounti...

Страница 11: ...then use an electric drill to make 3 holes for installing M6 expansion screws FIG 7 Standard Bracket Installation Step 1 After aligning the mounting bracket with the 3 holes made above tighten and fi...

Страница 12: ...NG SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide V1 1 03 21 P 12 of 24 FIG 9 Luminaire Mounting Adjust the luminaire angle with 6mm Allen key according to the actual need on s...

Страница 13: ...the packaging and place the unit on a level surface Ground Mounting Steps Please refer to wall wanting for ground mounting details Adjusting Angle Adjust the luminaire angle with 6mm Allen key accordi...

Страница 14: ...re from the packaging and place the unit on a level surface Plate Mounting Steps Place the mounting plate on the wall align the holes and mark them and then use an electrinic drill 4 holes for install...

Страница 15: ...rs should refer to their occupational safety and best practice guidelines when performing these tasks Adjust the luminaire angle with 6mm Allen key according to the actual need on site FIG 15 Adjustin...

Страница 16: ...tion box is utilized for termination of the power supply and data cables NOTICE Cable bend radius must NOT be less than the Minimum Bending Radius 4 X Cable Diameter as speci ed by cable manufacturer...

Страница 17: ...performing installation or inspection of data wiring CAUTION Make sure that the cable is protected from cuts and abrasions that may result in damage to the outer jacket CAUTION IP failure induced by...

Страница 18: ...tion Detail DMX DMX DMX DMX Data pair to luminaire To ProPoint luminaire Data pair from luminaire WAGO 221 412 Lever Nut Typical of 6 120 Ohm Terminator Orange DMX IN Red DMX IN Grey DMX OUT Purple DM...

Страница 19: ...hnology USITT DMX512 A Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories Fixture is RDM compatible Fixtures allow a universal input of 120V AC t...

Страница 20: ...ix 16DC in each unit s UID Using the RDM identify function locate a single unit in the installation The associated luminaire will flash Note the physical location of the flashing unit and then disable...

Страница 21: ...Parameter ID Description Default Value Note 0x00F0 DMX Start Address 1 0x1000 Identify Device 0 Changing value to 1 will cause fixture to flash 0x0081 Manufacturer Label Traxon Technologies Read Only...

Страница 22: ...ce Flickering Incorrect power input Excess products connected Ensure the input voltage is correct Ensure the power supplies are not overloaded due to an excess of fixtures connected Ensure that only 3...

Страница 23: ...1 03 21 P 23 of 24 7 APPENDIX UID Address Recording Table Luminaire UID DMX Address DMX Universe Fixture Mounting Location Note Unit 1 Unit 2 Unit 3 Unit 4 Unit 5 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 U...

Страница 24: ...heck for the latest updates and changes on the Traxon website 2021 TRAXON TECHNOLOGIES ALL RIGHTS RESERVED Information is subject to change without prior notice www traxontechnologies com www osram us...

Отзывы: