background image

www.traxontechnologies.com | www.osram.us/traxon

©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS 
PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Installation Guide

V1.0 12/21

P. 9 of 20

3.2.3  

Installation Sequence

1.  Measure the correct distances for brackets and install the Allegro Media Tube

®

 Lite fixtures.

2.  Connect the Allegro Media Tube

®

 Lite in the daisy-chain manner outlined in the System Diagram to form large 

installations.

3.  Perform functional check on all the Allegro Media Tube

®

 Lite and inspect cables and brackets for any 

damage. Check for any abnormalities with the control signal.

4.  Report any functional defect found to your nearest Traxon Technologies office. DO NOT attempt to install the 

Allegro Media Tube

®

 Lite with functional defects on-site.

3.3  On-Site Installation

• 

DO NOT attempt installation in wet or severe weather conditions.

• 

DO NOT leave and expose any  Allegro Media Tube

®

 Lite or LED Engines 

unconnected under wet/raining or snowing environment.

• 

IP failure induced by stressed/damaged cables during or after installation 

will not be under warranty by Traxon Technologies.

• 

ALWAYS keep the cables protected from sharp objects and ensure no 

damage is generated on the cable.

Failure to keep  Allegro Media Tube

®

 Lite within the operating temperature range of 

–40°C to +50°C / –40°F to 

+122°F 

 and storage temperature range of –40°C to +70°C / –40°F to +158°F will void the product’s warranty.

3.3.1  

On-Site Installation

1.  Fix brackets to installation surface with anchor bolts or screws (by others).
2.  The Allegro Media Tube

®

 Lite are interconnected using the IN and OUT cables/connectors on each end of 

the tube. Connectors will make an audible “click” when connected. Gently pull on the cables in opposites 
directions to ensure they are fully locked and do not come loose. The below diagram shows the Tube 
connections. Always remember to affix a Quick Lock Waterproof End Cap (sold separately) for the OUT 
connector of the final Tube in each daisy chain. See System Diagram for details.

FIG.7:   Allegro Media Tube

®

 Lite Connections

              

Starter Cable

End Cap

 
NOTE: Any water ingress incurred due to improper installation of cable connectors or Waterproof Quick Lock 
End Caps will not be covered under warranty by Traxon Technologies.

Содержание Traxon e:cue Allegro Media Tube Lite

Страница 1: ...Allegro Media Tube Lite INSTALLATION GUIDE V1 0 Cover Allegro Media Tube Lite RGBW Allegro Media Tube Lite RGB Allegro Media Tube Lite DW...

Страница 2: ...NDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide V1 0 12 21 P 2 of 20 CONTENT 1 Safety And Operation 3 2 Introduction 4 3 Installation 7 4 System Configuration 11 5 Care an...

Страница 3: ...and outdoor use Ensure product operates within the specified temperature range Refer to 7 TECHNICAL SPECIFICATION for more details The Allegro Media Tube Lite does not contain any user serviceable pa...

Страница 4: ...11 8 3 AL MT LT RGBW 1200 12PXL CR ETL 1200mm 47 2 12 AL MT LT RGB 300 3PXL CR ETL 300mm 11 8 3 AL MT LT RGB 1200 12PXL CR ETL 1200mm 47 2 12 AL MT LT DW 300 3PXL CR ETL 300mm 11 8 3 AL MT LT DW 1200...

Страница 5: ...L1 L2 A D L L1 L2 W1 W2 H2 H1 NOTE Please see CAD files for additional dimensional data W1 W2 H1 H2 A D L L1 L2 1200mm 48 24 5mm 0 96 33 3mm 1 31 58 2mm 2 29 31 2mm 1 23 240mm 9 45 850mm 33 46 1200mm...

Страница 6: ...with 120 Ohm Terminator Starter Cable Interconnection Cable End Cap with 120 Ohm Terminator Starter Cable Interconnection Cable 1m 5m 30m 3 28 16 40 98 43 0 14m 1m 4m 0 46 3 28 13 12 56 3mm 2 22 2 18...

Страница 7: ...e Allegro Media Tube Lite and appropriate LED Engines DMX512 to be used to control the Allegro Media Tube Lite Distance between each Tube for thermal expansion and maintaining pixel pitch Mounting dis...

Страница 8: ...unt the Allegro Media Tube Lite on site If the installation is to be left uncompleted overnight place all non connected LED Engines and the Allegro Media Tube Lite in an indoor environment 5 All units...

Страница 9: ...ing or snowing environment IP failure induced by stressed damaged cables during or after installation will not be under warranty by Traxon Technologies ALWAYS keep the cables protected from sharp obje...

Страница 10: ...ce of 4mm 0 16 between consecutive Allegro Media Tube Lite see below diagram FIG 8 Keep minimum distance between fixtures To maintain consistent LED pitch and to allow for thermal expansion a minimum...

Страница 11: ...512 For RGBW each pixel on the Tube uses six RGB 3 in 1 LEDs and six white LEDs for R G B and W channels Pixel number 1 begins on the IN connector side and it uses the first four channels RGB and DW w...

Страница 12: ...RKS OF TRAXON TECHNOLOGIES U S PATENTS E U PATENTS JAPAN PATENTS OTHER PATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide V1 0 12 21 P 12 of 20 6 DW LEDs DW Pixel n...

Страница 13: ...LT End Cap 120 terminator ETL AM444420055 Wiring diagram shows only typical connections Max number of fixtures is based on minimal interconnection lengths Actual number of fixtures is dependent on ca...

Страница 14: ...terconnection cable optional Tubes are daisy chained 1 2 3 4 5 1 2 3 4 5 Signal DMX DATA_GND DMX DC48V DC48V Address Color Green White Blue Black Red Brown Connection DMX DATA_GND DMX DC48V DC48V Do n...

Страница 15: ...IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OR Snake Mode Snake Mode OR For best color mixing results ensure the tubes have the same orientation and remain parallel to the main movement patte...

Страница 16: ...injury or property damage Do not use product s if cables are damaged Do not connect cables and connectors when wet or in wet area Moisture on bare connectors can cause electric shock and damage to pro...

Страница 17: ...Check power supply leads and wire connections Ensure output wires are connected with proper polarity Check if LED Engine s secondary output is working as specified Shadowing Light source covered Chec...

Страница 18: ...0 C to 50 C 40 F to 122 F Storage Temperature 40 C to 70 C 40 F to 158 F Allegro Media Tube Lite RGB Direct View Diffused View 300mm 11 8 1200mm 47 2 300mm 11 8 1200mm 47 2 Color Range 16 7 Million ad...

Страница 19: ...ctor devices their performances are subject to inherent variability commonly found in semiconductor industry To improve consistency in performance across the same product LED manufacturers sort LEDs i...

Страница 20: ...heck for the latest updates and changes on the Traxon website 2021 TRAXON TECHNOLOGIES ALL RIGHTS RESERVED Information is subject to change without prior notice www traxontechnologies com www osram us...

Отзывы: