www.traxontechnologies.com | www.osram.us/traxon
©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS
PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide
V1.0 12/21
P. 13 of 20
FIG.9: System Diagram
Tubes are daisy chained
Signal
DMX+
DATA_GND
DMX
–
DC48V
–
DC48V
+
Address
Color
Green
White
Blue
Black
Red
Brown
Connection
DMX+
DATA_GND
DMX
–
DC48V
-
DC48V
+
Do not connect
Pin#
1
2
3
4
5
6
AL MT LT End Cap
120Ω terminator
ETL(AM444420055)
Wiring diagram shows only typical connections. Max. number of fixtures is based on minimal interconnection lengths. Actual numbe
r of fixtures is
dependent on cable interconnections. Number of fixtures will reduce if longer cable lengths are used. Consult with your regional
sales office to
confirm maximums.
Color Type
Max. Daisy Chain
6m/19.69’
12m/39.37’
6m/19.69’
15m/49.21’
17m/55.77’
6m/19.69’
15m/49.21’
19.2m/62.99’
PSU Power
100W
240W
100W
240W
320W
100W
240W
320W
DMX In
LED Engine 48V Outdoor 100W/240W
(AA766150055/AM089330055)
AC 120V - 277V In
AL MT L
T Starter Cable, 6-wir
e
1m/5m/30m , ETL
(AM444390055/AM444400055/AM444410055)
1
2
3
4
5
6
4
5
3
2
1
6
Wire Gauge
2x18AWG
+
4x24AWG
RGBW
RGB
DW