background image

 

General

 

_________________________________________________________________________________  

OSRAM operating instructions DALI Repeater LI 

page 2 

Contents 

 

General 

 

 

Installation 
 
Operation 
 

 
 
 

 

 

Appendix 

Application and function ............................................................................................... 2
Safety information ........................................................................................................ 2
Design and dimensions ................................................................................................ 3
Wiring schemes............................................................................................................ 3
DALI operation with supervisory control unit ................................................................ 5

Touch DIM

 operation.................................................................................................... 5

Functional test .............................................................................................................. 6
Service button .............................................................................................................. 6
Indication LED .............................................................................................................. 7
Accessories (not included) ........................................................................................... 8
Technical data .............................................................................................................. 8
 

Application and function 

The DALI REPEATER LI allows to built up DALI systems with more than 64 ECG per DALI line. For 
the supervisory control unit it acts like a single ECG. On the other hand it is able to control up to 
64 DALI ECG. All ECG connected to the DALI REPEATER LI are set to the same dimming level. 
Switching state, dimming level and lamp failures can be queried via the Repeater. At the same time it 
allows the extension of the DALI line by 300 m each time. 

If the Repeater is used in Touch DIM operation, up to 64 DALI ballasts can be controlled by means of 
a common push button. The DALI REPEATER LI is designed for luminaire integration. With the 
LMS CI BOX an independent mounting, e.g. for recessed ceiling installation, is suitable.

 

 

Safety information 

 

 

 

The following information is provided for your safety:

 

 

Please read these operating instructions carefully before installing and using the DALI 
REPEATER LI. This is the only way to ensure that you use the equipment safely and 
correctly. Keep these operating instructions in a safe place for future reference. You should 
make sure that everyone who uses DALI REPEATER LI has read these operating 
instructions. 

 

DALI REPEATER LI may only be installed by qualified personnel who have been 
appropriately trained and who have the relevant authority. The installation personnel must 
be familiar with the operating instructions. Power must be switched off before any work is 
undertaken on the unit. 

 

The DALI REPEATER LI is especially designed for installation within luminaries, an 
independent installation is only allowed in combination with the mounting kit LMS CI BOX. 

 

The relevant safety and accident prevention regulations must be observed. 

 

The Touch DIM operation must not be used in parallel to operation with a DALI control unit. 
Only DALI or Touch DIM operation is allowed. 

 

The external switch for the Touch DIM operation must be designed for mains voltages. 

 

If the DALI output is wired with external voltage, particularly with a mains voltag, the unit 
may be destroyed. 

 

Содержание DALI Repeater LI

Страница 1: ...III 2008 DALI Repeater LI 001240508GB ZPE 2433444 OSRAM GmbH www osram com ecg lms Customer Service Center CSC www osram de evg lms Steinerne Furt 6286167 Augsburg Germany Tel 49 1803 677 200 charges apply Fax 49 1803 677 202 ...

Страница 2: ...unting e g for recessed ceiling installation is suitable Safety information The following information is provided for your safety Please read these operating instructions carefully before installing and using the DALI REPEATER LI This is the only way to ensure that you use the equipment safely and correctly Keep these operating instructions in a safe place for future reference You should make sure...

Страница 3: ... DALI ECG or further repeaters For maximum number of DALI devices please refer to the instructions of the control unit Maximum wire length at the output of the DALI Repeater is 300 m in total over both outputs Both outputs of the DALI Repeater LI are electrically interconnected To simplify the connection the layout is done by pairs Outputs of different Repeaters may not be interconnected with each...

Страница 4: ...rminals must not be connected The maximal overall wire length at the push button input should not exceed 100 m Further points of control can be achieved by parallel connection of several push buttons Push buttons with glow indication lamps in parallel to the push to make contact are inapplicable Both outputs of the DALI Repeater LI are electrically interconnected To simplify the connection the lay...

Страница 5: ...tion LED and Service button Touch DIM operation Before first manual operation the DALI Repeater should be initialised as follows Initialise is started by pressing the integrated service button of the DALI REPEATER LI for at least 0 5 s During initialise process the highest minimal dimming level of the connected DALI devices is detected and stored During this process the LED will flash in yellow Af...

Страница 6: ...n automatically As long as the functional test is active the indication LED of the repeater flashes alternating between green and yellow Service button The integrated service button of the DALI REPEATER LI provides following functionality During initialise process the highest minimal dimming level of the connected DALI devices is detected and stored It is started by pressing the integrated service...

Страница 7: ... activated by a short press on the service button flashing red green No DALI device at the output detected Broken wire connection at the output side or interruption of mains supply of the connected DALI devices yellow Lamp failure At least one of the connected DALI devices is indicating a lamp fail flashing yellow Initialising detection of highest minimal dimming level Initialise process was start...

Страница 8: ...p to 2 Touch DIM RC 4008321183033 Maintenance free battery less EnOcean transmitter technology inductive power generation Technical data Designation DALI REPEATER LI Supply voltage 100 240 V 50 60 Hz or DC Power consumption Depends on number of connected DALI devices max 4 W Control input DALI acc IEC 62386 102 201 DALI output max 64 DALI ECG respectivly max 130mA Wire cross section 0 5 1 5 mm 2 A...

Отзывы: