TSL2521 ALS/Flicker
TSL2521 ALS and Flicker Settings
Application Note
• PUBLIC
AN001042
• v1-01 • 2022-Jan-27
23
│ 10
Figure 8:
Step 0 of TSL2521 Sequencer with ALS and Flicker Measurement Activated
Figure 9:
Example Specification and Proposed Settings
Item
Value [dec.]
Customer Example Specification:
-
Update interval
< 0.5 s
-
ALS integraton time
50 ms
-
Max. flicker frequency
2 kHz
-
FFT bin size
10 Hz
Proposal:
-
Sample time
125 µs
-
Sample frequency
8 kHz
-
FFT size
1024
Settings for Proposal:
-
sample_time
89
-
als_nr_samples
399
-
fd_nr_samples
1023
400
4
1 2 3
ALS integration time
...
Pause
4
1 2 3
...
1
0
24
sample time
Flicker measurement time
ALS Result
FIFO used for Ficker data