17
Installation
4.4
DMX connection
The e:cue Bridge8 can control eight DMX universes with its eight DMX
ports. Connect DMX devices to the Node using 3-pin terminal plugs at the
DMX interface of the Node.
The appropriate pin assignment is defined as follows:
From left to right: GND, DMX-, DMX+
It is recommended to use twisted pair cabling.
Use shielded cables for outdoor installations.
4.5
Power supply
The e:cue Bridge8 can be powered by an external power supply or via
Power-over-Ethernet.
PoE:
For PoE, simply connect an Ethernet connection from a power sourcing
device.
External power supply:
Connect the e:cue Bridge8 to a certified
NEC
Class 2 24 V DC power
supply unit. Present power supply equates to the status “On” or running of
the Node.
i
Never connect more than one e:cue Bridge8 in factory state
to a network. The identical IP addresses will conflict and
disturb proper communication.
!
Ground the DMX connection cable for outdoor installations
(optional for indoor only). Ground each cable seperately.