LEXPERT EMPHASY
9
DMX Address
Press the MENU button up until the
information is displayed on the screen. Press the ENTER button and the display will blink. Use the
DOWN and UP buttons to change the value from
1
to
512
. Once the value has been selected, press the ENTER button to validate, to go back to the fun-
ctions without any change press the MENU button again. To exit, hold and press the MENU button about one second or wait for one minute to exit the
menu mode.
Channel Mode
Press the MENU button up until the
information is displayed on the screen. Press the ENTER button and the display will blink. Use the DOWN
and UP buttons to select the
1ch (8 bits)
or
2ch (16 bits)
. Once the mode has been selected, press the ENTER button to setup, to go back to the functions
without any change press the MENU button again. Hold and press the MENU button about one second or wait for one minute to exit the menu mode.
DMX 512 Configuration
1 CH MODE (MODE 1):
2 CH MODE (MODE 2):
DMX State
Press the MENU button up until the
information is displayed on the screen. Press the ENTER button, Use the DOWN and UP buttons to
select the
(blackout mode)
or
(last state)
. Once the mode has been selected, press the ENTER button to setup, to go back to
the functions without any change press the MENU button again. Hold and press the MENU button about one second or wait for one minute to exit the
menu mode.
Dimmer Mode
Press the MENU button up until the
information is displayed on the screen. Press the ENTER button. Use the DOWN and UP buttons to
select the
(dimmer 1)
,
(dimmer 2)
,
(dimmer 3)
or
(dimmer 4)
curve. Once the curve has been selected,
press the ENTER button to setup, to go back to the functions without any change press the MENU button again. Hold and press the MENU button about
one second or wait for one minute to exit the menu mode.
Mode 1(Optically Linear):
The increase in light intensity appears to be linear as DMX value is increased.
Mode 2(Square Law):
Light intensity control is finer at low levels and coarser at high levels.
Mode 3(Inverse Square Law):
Light intensity control is coarser at low levels and finger at high levels.
Mode 4(S-curve):
Light intensity control is finger at low levels and high levels and coarser at medium levels.
CHANNEL
VALUE
FUNCTION
1
000-255
DIMMER
0%~100%
CHANNEL
VALUE
FUNCTION
1
000-255
DIMMER
0%~100%
2
000-255
DIMMER FINE
0%~100%