DMX Address

Press the MENU button up until the 

information is displayed on the screen. Press  the ENTER button and the display will blink. Use the

DOWN and UP buttons to change the value from 

1

to 

512

. Once the value has been selected, press the ENTER button to validate, to go back to the fun-

ctions without any change press the MENU button again. To exit, hold and press the MENU button about one second or wait for one minute to exit the
menu mode.

Channel Mode

Press the MENU button up until the 

information is displayed on the screen. Press the ENTER button and the display will blink. Use the DOWN

and UP buttons to select the 

1ch (8 bits)

or 

2ch (16 bits)

. Once the mode has been selected, press the ENTER button to setup, to go back to the functions

without any change press the MENU button again. Hold and press the MENU button about one second or wait for one minute to exit the menu mode.

DMX 512 Configuration 

1 CH MODE (MODE 1):

2 CH MODE (MODE 2):

DMX State

Press the MENU button up until the 

information is displayed on the screen. Press the ENTER button, Use the DOWN and UP buttons to

select the  

(blackout mode)

or 

(last state)

. Once the mode has been selected, press the ENTER button to setup, to go back to

the functions without any change press the MENU button again. Hold and press the MENU button about one second or wait for one minute to exit the
menu mode.

Dimmer Mode

Press the MENU button up until the 

information is displayed on the screen. Press the ENTER button. Use the DOWN and UP buttons to

select the 

(dimmer 1)

(dimmer 2)

(dimmer 3) 

or 

(dimmer 4)

curve. Once the curve has been selected,

press the ENTER button to setup, to go back to the functions without any change press the MENU button again. Hold and press the MENU button about
one second or wait for one minute to exit the menu mode.

Mode 1(Optically Linear): 
The increase in light intensity appears to be linear as DMX value is increased.
Mode 2(Square Law): 
Light intensity control is finer at low levels and coarser at high levels.
Mode 3(Inverse Square Law): 
Light intensity control is coarser at low levels and finger at high levels.
Mode 4(S-curve): 
Light intensity control is finger at low levels and high levels and coarser at medium levels.

CHANNEL

VALUE

FUNCTION

1

000-255

DIMMER

0%~100%

CHANNEL

VALUE

FUNCTION

1

000-255

DIMMER

0%~100%

2

000-255

DIMMER FINE

0%~100%

Содержание ADB STAGELIGHT AL2319C41200

Страница 1: ...0 Warm White Black finishing AL2519C41201 LEXPERT EMPHASY DMX 19 Daylight Black finishing AL2526C41201 LEXPERT EMPHASY DMX 26 Daylight Black finishing AL2536C41201 LEXPERT EMPHASY DMX 36 Daylight Blac...

Страница 2: ...TION 2 FEATURE 3 SPECIFICATIONS 4 INSTALLATION 4 1 Lamp Hook Installation 4 2 How using a gobo and the gobo holder 4 3 Metal filter frame Installation 5 ELECTRICAL CONNECTION 6 DMX CONNECTION 7 MAIN F...

Страница 3: ...rachige Version des Handbuchs mit Sicherheitshinweisen f r dieses ADB Produkt unter folgendem Link herunterladen www adbstagelight com Rif FIS00V Safety Information LEXPERT Emphasy C mo obtener tu INF...

Страница 4: ...ing focus lens The product takes advantage of the heat pipe heat conduction and housing feature to dissipate heat without any fan Light Source 1 x 36W Cool Warm white LED Color temperature 3200k 150K...

Страница 5: ...03 801 2 3 1 3 Put the gobo by hand into the gobo holder insert the gobo holder into the slot of the unit Fix the clamp using the screw to the lamp hanger of the fixture as shown above and fasten the...

Страница 6: ...art of the filter frame holder by hand as displays the arrow and move away the Lock as the arrow then insert the metal filter frame into the inside slot from topside and close the frame holder Metal F...

Страница 7: ...peration 1 Always hold the plug when disconnecting a cable never pull the cable 2 Never use cables or connections in bad condition check them before installation and periodically thereafter 3 Never ti...

Страница 8: ...minaire s Dimming curve Menu 4 Control the luminaire locally Menu 7 Find out for how many hours the luminaire has been used Menu 9 Find out the firmware version number Menu 10 Accessing menus Press th...

Страница 9: ...on Use the DOWN and UP buttons to select the blackout mode or last state Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU b...

Страница 10: ...ess the ENTER button and the display will blink Use the DOWN and UP buttons to select dimmer Once the mode has been selected press the ENTER button to setup the value from 0 to 255 to go back to the f...

Страница 11: ...re the mains voltage on the main connector 2 The display is On Enter in Manual mode and set the value at 255 If the fixture doesn t light up contact your local dealer If the fixture lights up Check th...

Страница 12: ...I 24068 Seriate BG via Pastrengo 3 b Phone 39 035 654311 www adbstagelight com IST01W 001 EN Rev 0 12 2019...

Отзывы: