background image

Heating curves are a well established concept used
when designing commercial heating and ventilating
systems, but have never been widely used or
adopted in the UK for domestic installations – OSO
now bring this unique and energy saving feature to
the UK in our termo range of electric boilers.

By correctly setting the heating curve software
contained in the E version of the Termo electric boiler
energy consumption can be reduced by up to 20%.

The intelligent controls used monitor the outside
temperature in conjunction with the desired room
temperature and adjust the boiler output to only
supply enough energy to achieve the desired internal
temperature. The colder it is outside, the more heat
is required inside.

Heating requirements for properties vary according to
insulation levels and occupier preference. Choosing
the correct curve will depend upon the insulation
property of the building. Better insulated buildings
will have a lower heating curve and require less heat
than poorly insulated buildings.

The Termo boiler software contains several heating
curves to cover most eventualities.

Termo boilers have factory set heating curves to
match the 2000 Insulation Requirement of the
Building Regulations. Full guidance to the selection
of an appropriate heating curve is given in the easy
to use installation and user manuals.

Note: Heating curve software is only installed in the
E version of the OSO Termo Electric boiler.

A number of off peak electricity schemes are available*.

Economy 7*:

Will require two meters installed in the home.

Economy 7 tariff is not recommended with Termo
boilers as power will not be available to the boiler
during peak periods. 

Economy 10*:  

Requires one meter

Off peak times are generally set for
Midnight to 05.00 (gmt) 5 hours
13.00 – 16.00 (gmt) – 3 hours
20.00 – 22.00 (gmt) – 2 hours
Times vary with electricity suppliers.

Economy 14*:  

Requires one meter

Includes a long off peak time at night and other off
peak times available during the day. Times vary with
electricity suppliers.

By operating your Termo electric boiler with our
unique outside temperature compensator you can be
assured that your system will operate at its most
efficient and reduce / save energy – our electric
boilers are 100% efficient

The Termo electric boiler is versatile and can be
installed singly or as multiple units. Our boiler is easy
to site and can be fitted wherever there is an
electricity supply.

* You should make enquires with your electricity supplier
as to what tariff and duration are available in your area. 

heating 

curves

electricity 

tariffs

9

Feature

RS-M

RS-E

Plus-M

Plus-E

PTV-M

PTV-E

Suitable for open vented heating systems
Suitable for sealed heating systems
Suitable for water heating to an indirect cylinder
Suitable for sealed system without the need for S or Y plan system
Hot water cylinder sensor
Outside temperature sensor
Inbuilt 10 litre expansion vessel
Inbuilt 8 litre expansion vessel
Inbuilt 3 speed heating pump
Inbuilt 3 speed pump to cylinder
Two or three stage soft start
Inbuilt heating curve software
Air in boiler indicator
Low voltage warning light
Cascade power limiter option
240V single phase power supply
3 Year Guarantee
BEAB Approved

Y
Y
Y
Y
Y
Y
Y

N

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

Y
Y
Y
Y

N
N

Y

N

Y
Y
Y

N

Y
Y
Y
Y
Y
Y

Y
Y

N

Y

N

Y

N

Y
Y

N

Y
Y
Y
Y
Y
Y
Y
Y

Y
Y

N

Y

N
N
N

Y
Y

N

Y

N

Y
Y
Y
Y
Y
Y

Y
Y
Y

N
N
N
N
N
N
N

Y

N

Y
Y
Y
Y
Y
Y

Y
Y
Y

N

Y
Y

N
N
N
N

Y
Y
Y
Y
Y
Y
Y
Y

Содержание Termo Plus

Страница 1: ...oso termo electric boilers A unique domestic electric boiler from OSO with the advanced technology of a commercial boiler Clean 100 Efficient Flueless Quiet builds water heaters for the future...

Страница 2: ...antage offered by OSO can reduce energy consumption by as much as 20 Further heating curve information shown on page 9 E version boilers supplied for connection to hot water cylinders are also supplie...

Страница 3: ...rmo range of stylish compact boilers have a multitude of features that will benefit the developer builder and installer one such benefit where flue arrangements from a gas or oil boiler are difficult...

Страница 4: ...state of the art PCB control panel and a RCD safety switch The Termo RS E version boiler is supplied with inbuilt heating curve software outside temperature sensor and a hot water cylinder sensor Furt...

Страница 5: ...is supplied with our unique heating curve software and outside temperature sensor a correctly set heating curve working in conjunction with the outside temperature sensor will ensure only the require...

Страница 6: ...he output from the boiler using only the required amount of energy to raise the cylinder contents to the desired temperature The Termo PTV E can be used in conjunction with any standard or programmabl...

Страница 7: ...nder and boiler firing is controlled by the cylinder thermostat The Termo PTV M can be used in conjunction with any standard programmable room thermostat and system incorporating thermostatic radiator...

Страница 8: ...14 4 Power kW 6 Cap Lit A 330 B 930 C 230 D 100 E 65 F 320 Dim Mm 34 5 Dry Weight kg 0 25 2 5 Maximum operating pressure MPa bar 3 4 240V N 50 60 Hz Conn Power Supply technical information termo ptv e...

Страница 9: ...as power will not be available to the boiler during peak periods Economy 10 Requires one meter Off peak times are generally set for Midnight to 05 00 gmt 5 hours 13 00 16 00 gmt 3 hours 20 00 22 00 gm...

Страница 10: ...y to heat exchanger thus ensuring they are always in water 2 or 3 stage soft start feature ensures no power surges Suitable for use on open vented or sealed heating systems Three year guarantee Minima...

Отзывы: