6.1 Faults and fixes

If problems arise when the product is in use, 
check for possible faults and fixes in the table. If 
the problem is not shown in the troubleshoot-

6. TROUBLESHOOTING

ing table or you are unsure what is wrong, con-
tact the installer (see type plate on the product) 
or OSO Hotwater AS - see section 7.1.

TROUBLESHOOTING

Problem

Possible cause of fault

Possible solution

There is leakage/dripping 

from the safety valve/

there is often water on the 

floor by the cylinder in the 

morning

Pressure reduction valve, water meter 

or blocked non-return valve on the 

water intake.

Water pressure into the home is too 

high.

Fit AX expansion vessel with absorbs ex-

pansion during heating, and fit pressure 

reduction valve for stable water pressure 

inside the home. The pressure reduction 

valve is adjusted in according to the pres-

sure in the expansion vessel. Contact auth. 

installer.

The safety valve is worn or there are 

particles stuck between the mem-

brane and the valve seat because the 

water is dirty

Flush with water through the safety valve. 

Open valve for approx. 1 minute. See sec-

tion 5.2. If the valve still leaks, it must be 

replaced. Contact auth. installer.

Leak from heating element.

Verify as follows: a) cut the electric sup-

ply, b) unscrew the cover, c) visually check 

whether there is a leak from the heating 

element. If so, replace the gasket/heating 

element. Contact auth. installer.

No hot water

Power supply interrupted.

Verify that the fuse is on / the plug is 

plugged in to the wall contact / the earth 

breaker has not tripped.

Thermostat has cut out.

Press the ‘RESET’ button on the safety ther-

mostat; see ‘User guide’.

Heating element is defective.

Replace heating element. Contact auth. 

installer.

Leak in hot water pipe

Check the hot water pipes and taps in the 

house for leaks. If a leak is detected:  Con-

tact auth. installer.

Not enough hot water

High consumption in the home.

Raise the temperature on the thermostat 

to the maximum; see ‘User guide’.

Switch to a larger OSO water heater. Con-

tact auth. installer.

Not high enough tem-

perature

The thermostat is set for low tempera-

tures.

Raise the temperature on the thermostat 

to the maximum; see ‘User guide’.

Change from cold to hot water in taps. Contact auth. installer.

Fuse/earth breaker trips 

repeatedly

Possible fault in the heater’s electrical 

system.

Verify as follows: a) cut the electric supply, 

b) unscrew the cover, c) visually check the 

junction box for any problems. If so, con-

tact auth. installer to check. Fit the cover.

Knocking in the pipes 

when the hot tap is closed

Large pressure increase when the tap 

is closed quickly.

Completely normal. Fit AX expansion ves-

sel if troublesome. Contact auth. installer. 

Содержание 800 0051

Страница 1: ...ed by OSO Hotwater AS Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 Fax 47 32 25 00 90 E mail oso oso no www osohotwater com Nano N 5 l EN SAFETY INFORMATION O M INFORMATION INSTALLATION MAN...

Страница 2: ...Included in delivery 6 3 3 Product dimensions 6 3 4 Requirements for installation location 7 3 5 Pipe installation 8 3 6 Electrical installation 10 4 Initial commissioning 12 4 1 Filling with water 1...

Страница 3: ...y are accessible for fu ture reference The manufacturer assumes compliance by the end user with the safety oper ating and maintenance instructions sup plied and by the installer with the fitting manua...

Страница 4: ...d or changed from its original state Fitting an external control unit managing the power supply to the product is NOT allowed without approval from the manufacturer Children must NOT play with the pro...

Страница 5: ...2016 and EN 60335 2 21 as well as other useful data See Declaration of Conformity at www osohotwater co uk for more information OSO products are designed and manufactured in accordance with Pressure v...

Страница 6: ...x with screw holes for wall fittiing are now accessible Fitting the insulation cap 1 Press the front piece into the fasteners 2 Press the two end pieces into place Ensure that the locking mechanisms s...

Страница 7: ...The Nano is attached to the wall with the sup plied fastening metal band V see illustration The metal band is bent placed around the mid dle of the tank and fixed to the wall through the holes in the...

Страница 8: ...size to the connections tighten according to table 3 5 3 For larger pipe sizes a reducer can be used C The safety valve supplied 3 must be fitted to the incoming CW supply pipe D Any overflow pipe 5...

Страница 9: ...frost free with a fall to the drain CAUTION Fixed electric fittings shall be used for installation in new homes or when changing an existing electrical setup in accordance with regulations The produc...

Страница 10: ...an then be connected to a 10A fuse Must be per formed by an authorized electrician 3 6 Electrical installation 3 6 1 Electrical components Component Note Safety thermostat 85 C thermal cut out Work th...

Страница 11: ...r rating is 230V x 3kW All internal wiring is factory fitted 3 6 5 Installation instructions 3 6 6 Fitting recommendation WARNING Fitting an external control unit managing the power supply to the prod...

Страница 12: ...LLER MUST Brief the end user on safety and maintenance instructions Brief the end user on settings and emptying the product Hand this installation manual over to the end user Enter contact details on...

Страница 13: ...all be carried out by persons over 18 years of age with sufficient understanding Annual inspection of safety valve Open valve for 1 min by turning the knob 2 approx 90 degrees to the open position Vis...

Страница 14: ...ic sup ply b unscrew the cover c visually check whether there is a leak from the heating element If so replace the gasket heating element Contact auth installer No hot water Power supply interrupted V...

Страница 15: ...stic mains water supply in compliance with the European Drinking Water Directive EN 98 83 EC or latest version The water should not be aggressive i e the water chemistry shall comply with the followin...

Страница 16: ...l 47 32 25 00 00 oso oso no www osohotwater com This installation manual and all its content is protected by copyright and may be reproduced or distributed only with written consent from the manufactu...

Отзывы: