background image

22

8.1  Customer service

In case of problems that cannot be resolved 

with the aid of the troubleshooting guide in this 

installation manual, contact either:

A) The installer who supplied the product. 

9. REMOVING THE PRODUCT

9.1 Removal

A) Switch off, isolate and make power supply safe.

B) Shut off incoming cold water supply.

C) Empty the product of water – see section 4.4.

D) Disconnect all pipes.

E) The product can now be removed.

9.2 Returns scheme

This product is recyclable and should be taken to 

the environmental recycling centre. If the prod-

uct is to be replaced with a new one, the installer 

can take the old cylinder away for recycling.

8. WARRANTY - OSO UNVENTED HOTWATER CYLINDER

1. Scope

OSO  Hotwater  UK  Ltd.  (hereinafter  called  OSO)  warrants  for  2 

years from the date of purchase, that the Product will: i) conform 

to  OSO  specification,  ii)  be  free  from  defects  in  materials  and 

workmanship, subject to conditions below. All components carry 

a 2-year warranty. 

The warranty is voluntarily extended by OSO to 25 years for the 

stainless steel inner tank. This extended warranty only applies to 

Products  purchased  by  a  consumer,  that  has  been  installed  for 

private use and that has been distributed by OSO or by a distributor 

where the Products have been originally sold by OSO.

The extended warranty does not apply to Products purchased by 

commercial  entities  or  for  Products  that  have  been  installed  for 

commercial  use.  These  shall  be  subject  only  to  the  mandatory 

provisions of the law. The conditions and limitations set out below 

shall apply.

2. Coverage

If a defect arises and a valid claim is received within the statutory 

warranty period, at its option and to the extent permitted by law, 

OSO shall either; i) repair the defect, or; ii) replace the product with 

a product that is identical or similar in function, or; iii) refund the 

purchase price.

If a defect arises and a valid claim is received after the statutory 

warranty  period  has  expired,  but  within  the  extended  warranty 

period,  OSO  will  supply  a  product  that  is  identical  or  similar  in 

function. OSO will in such cases not cover any other associated 

costs. In addition, for every year after the statutory warranty period, 

the claimant must contribute 4 % of the list price of the cylinder in 

question to OSO.

Any  exchanged  Product  or  component  will  become  the  legal 

property of OSO. Any valid claim or service does not extend the 

original warranty. The replacement Product or part does not carry 

a new warranty.

3. Conditions

The Product is manufactured to suit most public water supplies. 

However, there are certain water chemistries (outlined below) that 

can have a detrimental effect on the Product and its life expectancy. 

If there are uncertainties regarding water quality, the local water 

supply authority can supply the necessary data.

The warranty applies only if the conditions set out below are met 

in full:

The Product has been installed by a professional installer, in 

accordance with the instructions in the installation manual 

and all relevant Codes of Practice and Regulations in force at 

the time of installation.

The Product has not been modified in any way, tampered 

with or subjected to misuse and no factory fitted parts have 

been removed for unauthorized repair or replacement. 

The Product has only been connected to a domestic mains 

water  supply  in  compliance  with  the  European  Drinking 

Water Directive EN 98/83 EC, or latest version. The water 

should  not  be  aggressive,  i.e.  the  water  chemistry  shall 

comply with the following:

- Chloride 

 

< 100 mg / L

- Electric Conductivity (EC) @25°C

< 300 uS / cm

 -Saturation Index (LSI) @80°C   

> - 1,0 / < 0,8

- pH level 

 

> 6,0 / < 9,5

Storage temperature shall not exceed 65°C. 

The immersion heater has not been exposed to hardness 

levels exceeding 10°dH (180 ppm CaCO3). A water softener 

is recommended in such cases.

Any  disinfection  has  been  carried  out  without  affecting 

the  Product  in  any  way  whatsoever.  The  Product  shall  be 

isolated from any system chlorination.

The  Product  has  been  in  regular  use  from  the  date  of 

installation. If the Product is not intended to be used for 60 

days or more, it must be drained.

The  immersion  heater  element  must  be  removed  for 

inspection  on  service  after  5  years.  The  threads  must  be 

checked  for  corrosion.  If  signs  of  corrosion  are  evident, 

the  element  must  be  replaced.  Subsequently  the  element 

must  be  removed  and  examined  every  3  years.  Failure  to 

do so in areas of aggressive water may result in the element 

separating from the cylinder with consequential escape of 

water.

Service  and/or  repair  shall  be  done  according  to  the 

installation manual and all relevant codes of practice. Any 

replacement parts used shall be original OSO spare parts.

The  Service  record  /  Benchmark  logbook  has  been 

completed and updated after each annual service. Invoices 

should be kept as proof of service.

The Commissioning Checklist / Benchmark certificate has 

been completed at the time of installation.

Any  third-party  costs  associated  with  any  claim  has  been 

authorized in advance by OSO in writing. 

The  purchase  invoice  and/or  installation  invoice,  a  water 

sample as well as the defective product is made available to 

OSO upon request. 

Failure  to  follow  these  instructions  and  conditions  may  result  in 

product failure, and water escaping from the Product.

4. Limitations

The warranty does not cover:

Any fault or costs arising from incorrect installation, incorrect 

application, lack of regular maintenance in accordance with 

the  installation  manual,  neglect,  accidental  or  malicious 

damage,  misuse,  any  alteration,  tampering  or  repair 

carried  out  by  a  non-professional,  any  fault  arising  from 

the  tampering  with  or  removal  of  any  factory  fitted  safety 

components or measures.

Any consequential damage or any indirect loss caused by 

any failure or malfunction of the Product whatsoever.

Any pipework or any equipment connected to the Product.

The effects of frost, lightning, voltage variation, lack of water, 

dry boiling, excess pressure or chlorination procedures.

The effects of stagnant (de-aerated) water if the Product has 

been left unused for more than 60 days consecutively. 

Damage caused during transportation. Buyer shall give the 

carrier notice of such damage.

Costs arising if the Product is not immediately accessible for 

servicing.

These warranties do not affect the Buyer’s statutory rights.

B)  OSO Hotwater UK Limited: 

Tel.: (0191) 482 0800   Fax: (0191) 491 3655

Email: [email protected]

Содержание 1327051

Страница 1: ...146243 00 10 2021 Ecoline SCE 120 150 180 210 250 300 l EN SAFETY INFORMATION O M INFORMATION INSTALLATION MANUAL TDS TECHNICAL DATA SHEET ...

Страница 2: ...erate injury or damage to property DO NOT DO This document must be kept in a suitable place where it is accessible for future reference 4 Electrical installation 4 1 lmmersion heaters 10 4 2 Wiring of immersion heaters 10 4 3 Electrical connections 10 4 4 System wiring 10 4 5 S plan wiring layout 12 4 6 Y plan wiring layout 13 5 Safety and servicing 5 1 Safety cut out 14 5 2 Intermittent discharge...

Страница 3: ... Maintenance settings shall only be carried out by persons over 18 years of age with suf ficient understanding CAUTION The product must not be exposed to frost over pressure over voltage or chlorine treat ment See warranty provisions Maintenance settings shall not be carried out by persons of diminished physical or men tal capacity unless they have been instructed in the correct use by someone res...

Страница 4: ...rd water regions precautions should be tak en to prevent limescale formation in hot water cylinders in accordance with Building Regulation Part L Domestic Heating Compliance Guide This OSO cylinder must be installed by a com petent person and be installed in compliance with the OSO Installation and Maintenance In structions all current legislation codes of prac tice and regulations governing the i...

Страница 5: ...ntly frost free position The product shall be placed on a floor or wall suitable for the total weight of the product when in operation See type plate The product must have a clearance for servicing of 400 mm in front of the immersion cover 150 mm above the highest point The product shall be easily accessible in the home for servicing and maintenance CAUTION Tappings valves etc shall not be used to...

Страница 6: ...ements An uninterrupted 22 mm cold water mains supply is recommended however if only a 15 mm supply is available this may be used provided there is suffi cient flow rate available A minimum standing pres sure of 2 5 bar and a flow rate of 20 litres per minute with a 1 bar dynamic pressure is recommended The cylinder will operate at lower pressures and flow rates however the performance will be com...

Страница 7: ... mm hot water draw off 12 on top of cylinder 2 14 Balanced cold water supply optional If no balanced cold supply is required tighten the supplied blanking cap If a balanced mains pressure cold water sup ply is required to a shower or bidet over rim type only ascending spray type requires type AA AB or AD air gap remove blanking cap and connect to the shower or bidet cold sup ply 2 on the combinati...

Страница 8: ...safe visible position If any doubt refer to Building Regulation G3 Discharge pipe must be dedicated to the cyl inder and must not be used for any other pur pose see page 15 2 17 Primary Flow and Return The boiler primary flow and return connections should be made to flow and return conections on top of cylinder To comply with regulations governing the installation of indirect unvent ed cylinders a...

Страница 9: ...scharge pipe by turning knob counter clockwise To close continue to turn knob counter clockwise until the valve shuts 6 Switch electrical power on 3 2 Draining Switch off the electrical power Attach a hose to drain valve 6 open valve to drain Open a hot tap Draining process may be speeded up by opening the Temperature and Pressure relief valve 4 A hose can be applied to the cold water connection t...

Страница 10: ...ll cables should comply with BS6141 table 8 HOFR 85c IEE wiring regulations must be fol lowed throughout All internal wiring is factory mounted Each im mersion heater has a working thermostat adjust able between 40 C 70 C A safety cut out is also incorporated within the thermostat and will operate at 85 C 3 C Should this happen check reasons for thermal cut out button being released and when satis...

Страница 11: ...ed valve which will act as a positive en ergy cut out should the safety cut out operate The motorised valve will also control the tempera ture of the domestic stored water via the cylinder thermostat which is located in the electrical box The unit should be installed on an S or Y plan system Please follow the wiring instructions carefully The working thermostat which controls the tem perature of t...

Страница 12: ... HW on H on N L E N L E N L Boiler Pump 3 2 1 3 2 3 2 2 2 3 1 V4043H Zone Valve DHW supplied IMMERSION thermostat CYLINDER thermostat Isolated Mains Supply From Fused Spur L N E Zone Valve Htg not supplied Room thermostat 6 9 B1 Br G O G Y 2 3 1 V4043H 4 8 10 L N Terminal for Y plan system 2 Port V alv e supplied Pump flow A uto matic bypass ...

Страница 13: ...at Zone Valve DHW supplied IMMERSION thermostat CYLINDER thermostat Isolated Mains Supply From Fused Spur L N E Mid Position Valve not supplied 6 W B1 G Y Gr O 2 3 V4073A1039 10 L N 4 5 9 8 7 4 6 Y plan wiring layout 2 Port V alv e supplied M id Position V alv e not supplied Pump flow A utomatic bypass A Honeywell 10 way Junction box must be used in a Y plan system No other wiring centre is accept...

Страница 14: ...k the precharge the expansion vessel must be completely empty of water if the pressure is different from the value shown on the label it must be restored to the original value Do not remove expansion vessel without depres surising the cylinder and draining 10 litres of wa ter from the drain valve at the base of the cylinder 5 5 Warranty Cylinder should be serviced annually as below and logbook sho...

Страница 15: ...mm 28 mm 35 mm up to 9 m up to 18 m up to 27 m 0 8 m 1 0 m 1 4 m G 3 4 22 mm 28 mm 35 mm 42 mm up to 9 m up to 18 m up to 27 m 1 0 m 1 4 m 1 7 m G 1 28 mm 35 mm 42 mm 54 mm up to 9 m up to 18 m up to 27 m 1 4 m 1 7 m 2 3 m the end of the discharge pipe clearly visible tundish visible or not or onto a roof capable of withstand ing high temperature discharges of water and 3 m from any plastics gutte...

Страница 16: ...ld water inlet pressure reducing valve not working Temperature and pressure relief valve faulty Check and open stopcock Turn off water supply remove and clean strainer Check and switch on Check and press reset button Check and set to Hot water Check boiler operation If fault suspected consult in staller boiler manufacturer Check and press reset button Check wiring and or plumbing connections to mo...

Страница 17: ...lcapacity L 12 12 18 18 25 25 HeatExchangerinformation Primaryheatexchangersurfacearea m 0 5 0 8 0 8 0 8 0 8 0 8 Øint etØext mm mm ø20 4 ø22 ø20 4 ø22 ø20 4 ø22 ø20 4 ø22 ø20 4 ø22 ø20 4 ø22 Øint etØext mm mm N A N A N A N A N A N A Hydraulicconnections Secondaryreturn mm N A N A N A N A N A N A Primaryheatexchangerflow mm ø22 ø22 ø22 ø22 ø22 ø22 Primaryheatexchangerreturn mm ø22 ø22 ø22 ø22 ø22 ø...

Страница 18: ...18 NOTES ...

Страница 19: ... Regulations 3 Failure to install and commission this appliance to the manufacturer s instructions may invalidate the guarantee The above does not affect your statutory rights For full details on the HWA charter please visit http www hotwater org uk HEATING AND HOTWATER INFORMATION COUNCIL IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOG BOOK AND PASS IT ON TO THE CUSTOMER FAILURE TO...

Страница 20: ...IFFERENT NAME DATE ADDRESS TEL No REGISTERED OPERATIVE ID CARD No IF APPLICABLE REGISTRATION DETAILS IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOGBOOK AND PASS IT ON TO THE CUSTOMER FAILURE TO DO SO MAY INVALIDATE THE CYLINDER GUARANTEE APPLIANCE TIME CONTROL DETAILS MANUFACTURER OSO HOTWATER UK MODEL CAPACITY TYPE TIME CONTROL UNVENTED PROGRAMMER litres MANUFACTURE date TIME SWIT...

Страница 21: ...WHAT IS THE PRESSURE REDUCING VALVE SETTING IF FITTED WHERE IS OPERATING PRESSURE REDUCING VALVE SITUATED NO YES NO bar HAS THE EXPANSION VESSEL OR INTERNAL AIR SPACE BEEN CHECKED YES NO WHAT IS THE HOT WATER TEMPERATURE AT THE NEAREST OUTLET C bar ALL PRODUCTS YES DOES THE HOT WATER SYSTEM COMPLY WITH THE APPROPRIATE BUILDING REGULATIONS HAS THE SYSTEM BEEN INSTALLED AND COMMISSIONED IN ACCORDANC...

Страница 22: ... been modified in any way tampered with or subjected to misuse and no factory fitted parts have been removed for unauthorized repair or replacement The Product has only been connected to a domestic mains water supply in compliance with the European Drinking Water Directive EN 98 83 EC or latest version The water should not be aggressive i e the water chemistry shall comply with the following Chlor...

Страница 23: ...o COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 5 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 7 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 9 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 2 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 4 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 6 COMPANY NA...

Страница 24: ...uk oso hotwater co uk E mail sales uk oso hotwater co uk OSO Hotwater AS Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 oso oso no www osohotwater com This installation manual and all its content is protected by copyright and may be reproduced or distributed only with written consent from the manufacturer We reserve the right to make changes without notice ...

Отзывы: