background image

 

9

DELAMINATION:

Delamination is when the layers within 
the structure of the mattress cover 
separate. This can be caused by using 
incorrect chemicals or too high a 
concentrate of cleaning chemicals on 
the surface. 

HOW TO PREVENT DELAMINATION:

OSKA

TM

 V-GUARD

TM

 Technology covers 

incorporate a special layering system 
to make them much more resistant to 
delamination than many other mattress 
covers. However, to help prevent 
delamination:

1.

Always abide by the cleaning
instructions

2.

Avoid using chemicals with too high

concentration.

3.

Ensure cleaning chemicals are always

thoroughly rinsed off before allowing
to dry

4.

The V-GUARD

TM

 covers can tolerate

up to 10,000ppm chlorine but using
a weaker solution of 1,000ppm will
reduce the risk of a high concentrate
being left on the surface

5.

Ensure the covers are thoroughly dry

before using or storing the mattress

STRIKETHROUGH:

Strikethrough occurs when the fibres 

in the mattress covers start to break 
down. Small cracks develop, which on 
inspection, may not be visible. This 

means fluids and other contaminates 

can pass through the cover and 
contaminate the core of the mattress.

HOW TO PREVENT STRIKETHROUGH:

Covers are most susceptible to 
strikethrough damage when they 
are wet. During cleaning, extra care 
should be taken to avoid abrasion 
of the surface. OSKA

TM

 V-GUARD

TM

 

Technology covers incorporate a special 

4. STORAGE

5. DAMAGES AND REPLACEMENT

detergent. Do not use abrasive 
cleaners.

Disinfect in situ using 0.1% sodium 
hypochlorite solution (1000ppm 
available chlorine). Wipe off 
any residue with clean water. 
V-GUARD

TM

 covers can tolerate

10,000ppm chlorine but using
a weaker solution of 1,000 ppm
will reduce the risk of a high
concentrate being left on the
surface.

The fabrics are able to be washed 
in warm soap water at up to 95°C. 

All cleaning agents and 
disinfectants must be thoroughly 
rinsed off and the item dried before 
storage.

Spin and tumble dry on a low 
setting (not more than 130°c. The 
fabric surface may wrinkle but 
this will not impede function). The 
operator ensures it is removed as 
soon as all moisture is removed. 
The fabric must not be left sitting 
on the heated bowl of the drier 
when drying is complete.

Do not mangle.

Do not iron. 

Store in a cool dry area.

Avoid excessive pressure and 
always thoroughly dry fabric before 
re-use or storage. Do not fold away 
wet or store in damp conditions.

Keep away from sharp objects.

Regularly check the inside of the
cover for any signs of leakage

If the cover leaks then the 
waterproof barrier has been 
broken and a new cover should be 
purchased from OSKA

TM

.

2.3

2.4

2.5

3.1

 

3.2
3.3

 

4.1
4.2 

4.3 

5.1 

5.2

3. DRYING

HOW TO PREVENT DELAMINATION:

OSKA

TM

 Technology covers incorporate

a special layering system to make them 
much more resistant to delamination 
than many other mattress covers. 
However, to help prevent delamination:

HOW TO PREVENT STRIKETHROUGH:

Covers are most susceptible to
strikethrough damage when they
are wet. During cleaning, extra care
should be taken to avoid abrasion
of the surface. OSKA

TM

 covers 

incorporate a special

1. 

Always abide by the cleaning instruc-
tions

2. 

Avoid using chemicals with too high 
concentration.

3. 

Ensure cleaning chemicals are always 
thoroughly rinsed off before allowing 
to dry

4. 

The covers can tolerate up to 
10,000ppm chlorine but using a 
weaker solution of 1,000ppm will 
reduce the risk of a high concentrate 
being left on the surface

5. 

Ensure the covers are thoroughly dry 
before using or storing the mattress

10   

layering system to make them much 
more durable than many other mattress 
covers. However, to help prevent 
strikethrough:

1.

Always abide by the cleaning
instructions

2.

Avoid using chemicals with too high
concentration.

3.

Ensure cleaning chemicals are always

thoroughly rinsed off before allowing
to dry

4.

The covers can tolerate up to

10,000ppm chlorine but using a
weaker solution of 1,000ppm will
reduce the risk of a high concentrate
being left on the surface

5.

Ensure the covers are thoroughly dry

before using or storing the mattress

GENERAL INFORMATION

STORAGE:

or carefully rolled/folded with the 
zip closed. Always store at room 
temperature in a dry area. Make sure 
the mattress is stored where it will not 
be exposed to thrusts, hits or other 
things that can damage it. Avoid direct 
exposure of sunlight. If the mattress is 
to be stored more than 3 months, we 

(not folded or rolled up).

SERVICE AND REPAIRS

Only spare parts which have been 
approved by OSKA

TM

 should be used. 

Using non-approved spare parts will 
invalidate the warranty.
You must submit a warranty claim to 
OSKA

TM

 before the product is returned.

If you have questions regarding 
warranty and service please contact 
OSKA

TM

.

WARRANTY 

The warranty is based on statutory  
regulations. The warranty does not 
apply if the goods supplied by OSKA

TM

 

by other parties without prior consent 
from OSKA

TM

 or if these operating 

instructions are not followed.
For medical devices as understood by 
the EU - Directive 93/94, whose usage 
(also operations) is subject to regular 
service and maintenance, a warranty can 
be offered only if the service intervals 
prescribed by OSKA

TM

 are adhered to.

If during inspection it is found that 
damages are due to wear and tear 
or are not subject to warranty, then 
OSKA

TM

 are empowered to claim the 

expenses (inspection, transport costs 
etc) from the client. The use of parts or 
individual components of other systems 
or products or combinations thereof are 
not permissible.
Warranty claims become invalid should 
any damage result from this kind of 
conduct and therefore remain the 
responsibility of the user/owner.

V-GUARD

TM

 COVER - 4 YEARS PRO

RATA

Year 1 - 100%
Year 2 - 75%
Year 3 - 50%
Year 4 - 25%

BASE COVER / FOAM/ AIR CELLS - 
2 YEARS PRO RATA

Year 1 - 100%
Year 2 - 50%

11 

Содержание 3-V4 Series

Страница 1: ...of shear damage The easy to use fully digital pump has very clear weight settings and alternating cycle settings h Risk y 4 ment mfort control to wires gainst t of t WELDED SEAMS Regular sewn seams ar...

Страница 2: ...2 oska uk com 0845 381 0600 CHANGING LIVESTM...

Страница 3: ...E THE WARNING INSTRUCTIONS BEFORE USING THE SYSTEM CONTENTS Know your symbols Warning About your mattress How to set up your mattress System set up Cleaning Safety General information Warranty Trouble...

Страница 4: ...at persons must obey to avoid equipment damage Machine wash at 95 Manufacturer Drip dry Follow Instructions for Use 1 Chlorine Foot end Do not iron Group of function Tumble dry Separate Collection use...

Страница 5: ...imultaneously DO NOT USE Position the mattress correctly to prevent it becoming trapped and damaged NOTE Bed rails can trap the mattress and cause damage length and width of the mattress are appropria...

Страница 6: ...y 4 CAPACITY OSKATM Series3 V4 is recommended for UNPACKING THE MATTRESS Please ensure the box is not damaged upon arrival Avoid using a knife when opening the box and any other protective material as...

Страница 7: ...ton and its indicator will come on see 6 Press the button again to switch back to alternate mode OSKA 2016 4 1 2 3 4 5 6 Place pump on horizontal surface or hang by means of the hook Open mattress on...

Страница 8: ...inutes In the case of a poor connection with tubing or any other air leakage from the mattress low pressure conditions will occur and the audible visual alarm will be activated OPERATION 1 During norm...

Страница 9: ...lest breach of this barrier will cause fluid to penetrate the mattress There are specific cleaning and care instructions that need to be strictly adhered to prolong the life of the product DELAM Delam...

Страница 10: ...nt They may be disposed of with the household waste The pump control unit is considered as electrical equipment waste Please contact the proper waste disposal officials Part Description Part No In the...

Страница 11: ...uring cleaning extra care should be taken to avoid abrasion of the surface OSKATM covers incorporate a special 1 Always abide by the cleaning instruc tions 2 Avoid using chemicals with too high concen...

Страница 12: ...subject to regular service and maintenance a warranty can be offered only if the service intervals prescribed by OSKATM are adhered to If during inspection it is found that damages are due to wear and...

Страница 13: ...et connectors on the side of the pump Contact OSKA Service There are no leaks in the mattress Contact OSKA Service Contact OSKA Service There are no kinks in the tubing down side of the mattress Caref...

Страница 14: ...nance or interferences by an unauthorised party will also invalidate the product s warranty OSKA Series3 V4 Power supply 220 240V 50Hz 1A Air output 7 liter min Pressure range 20 70 mmHg Cycle time 10...

Страница 15: ...know that every patients need is different and so do we That s why our 3c solution helps us to help you deliver the highest standard of care possible CLINICAL Outstanding performance Prevention is be...

Страница 16: ...1 3 College Hill London EC4R 2RA 2 Selgar Ave Clovelly Park SA 5042...

Отзывы: