![Ositech comm 28800 Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/ositech-comm/28800/28800_users-manual-and-reference_1655820081.webp)
User’s Guide and Reference
5- 3
Modem Test Procedures
Local Analog Loopback
This test checks the path between the local Modem and the PC. The test
is only functional when the Modem is in direct mode (&Q0) and the COM
port baud rate is set to 14400 bps (Trumpcard 14400) / 28800 bps
(Trumpcard 28800) or less.
To start this test, the Modem must be in command mode.
To run this test:
1. Enter
AT&T1 [ENTER]
. Wait until the Modem returns a
CONNECT
message.
2. Enter a test message. For example,
“This message should be
echoed back.”
The message should immediately appear on the screen as you enter
it.
3. Enter
+++
(the escape sequence).
The Modem will respond with
OK
. The Modem is now in command
mode.
4. Enter
AT&T0 [ENTER]
to end the test.