Table 4-1.
Maintenance Standstill Cleaning
Standstill Cleaning
Levels
Machine Hours
Since Last
Cleaning
System Distress
Light
SCR Cleaning
Light
Derate
Comments
0
Normal
Operation
0-500
- -
- -
None
Between 500 and 1000 hours, clean
-
ing cycle can be initiated with JLG
analyzer.
500-1000
1
Standstill
Required
1000-1100
- -
0.5 Hz
None
Engine coolant temperature must
be >40° C and DEF must be thawed
before cleaning can be initiated.
2
Warning
Level
1100-1125
Continuous
0.5 Hz
Machine placed in
Creep and DTC
active
3
Shut Off
Level
>1125
Blinking
3 Hz
Idle Lock. Boom
Functions Locked
Out and Trapped in
Transport.
Contact Deutz Dealer.
!
!