Operating manual external touch control panel (Smart) Page: 4 of 14
4.)
Insert the control panel into the housing and screw it to the metal frame with the
enclosed screws. All screws must be screwed in to prevent water from entering.
The seal must not be damaged.
5.)
Carefully place the cover frame with the magnetic holder. The magnets must
engage in the recesses of the board.
Electrical Connection
The electrical connection as well as the work of adjustment and servicing should be carried
out only by an approved electrician! The connection diagrams enclosed and the relevant
safety provisions applicable must be observed and followed.
Low-voltage cables
Low-voltage cables should not be laid along with three-phase or AC cables in the same cable duct.
In general, laying low-voltage cables near three-phase or AC cables must be avoided.
Wiring diagrams
The power supply for the touch control panel can either be via EUROMATIK.net or via an external
power supply unit. Data communication is carried out via osf bus. Several devices can be connected
to the osf bus. Note the polarity of the bus line!
Connection of devices via the digital data bus
„osf bus“
Devices connected via the osf bus communicate automatically with the control panel. Below is a list of the
devices that are connected via the osf bus data bus: Euromatik.net, PC-40.net, Attraction-Control.net, Color-
Control.net, all Waterfriend MRD dosing stations and the Silver- Steam.net steam generator.
Connection with EUROMATIK.net
A 4-core cable 4x0.5mm² (e.g. J-Y (St) Y 2x2x0.8, Art. No. 102.000.1012) with a maximum length of 50m is
used to connect to Euromatik.net.