background image

Operating Instructions PC-25 page 6 (10)

Select operation mode

With the key   the control can be switched off and it can be selected
between manual and automatic operation respectively. 

Attention!

 By doing

so the control is not switched to zero potential! The selected operation
mode is displayed via pilot lights next to the   key. If the pilot light  "OFF/0"
is flashing, the filter pump has been switched off by the motor protection.
Before switching on the filter system again, this error message has to be
confirmed by pressing the   key.

Pilot light pump

This pilot light indicates the operation of the filter pump. You can see the
operation mode from the colour of the light:

green:

 Normal operation of the filter pump.

yellow:

 The pump has been switched on by the level control NR-12-TRS-2

or the backwash control EUROTRONIK, or the filter pump is running after
the additional heating has been switched off.

red:

 The pump has temporarily been switched off by the level control NR-

12-TRS-2 or the backwash control EUROTRONIK .

Pilot light heating

This pilot light indicates the operation of the heating. The operation mode
can be seen by the colour of the light:

green:

 The temperature control is running, the selected water temperature

has been reached.

yellow:

 The heating is running, the selected temperature has not been

reached yet.

red:

 The additional heating has temporarily been switched off due to a lack

of a normal filter operation or because the solar heating is currently running.

Solar heating

If a solar sensor is connected to the control these two pilot lights will display
the current operation mode of the solar heating:
If the upper light is red and the down light green, the water is flowing
through the heat exchanger and can be heated with the additional heating.
If the upper light is green and the down light is red, the solar heating is
being used and the additional heating is switched off.
You can check the temperature at the solar sensor by using the   key.

Select temperature

The temperature of the pool water is selected by using the   key:

1. Press key    

 the display indicates 

24,5

pool

°C

2. Now the requested temperature within a range of 0.1°C  up to 40°C can

be set with the keys   and   .

3. To save the requested temperatures, please press the   key again. If no

key is pressed for more than 10 seconds on the temperature setting, then
the last selected temperature will be automatically saved and the normal
operation display will appear again.

Содержание 3100000430

Страница 1: ...TRONIK 10 enable an upgrade of the filter control to an automatic filter and backwash control By using additional connecting terminals it is possible to connect accessory devices such as dosing equipm...

Страница 2: ...housing it is absolutely necessary to switch the device to zero potential Electrical connection The electrical connection as well as adjustment and service work may only be carried out by accredited...

Страница 3: ...ng PC 25 max 4A 22 23 heating 230V L1 N PC 25 heating 22 23 flow monitor L1 N or STB 400V L1 L2 L3 PC 25 U2 N 6 2 3 U3 actuator 230V Solar The floating relay contact between the clamps 22 and 23 can b...

Страница 4: ...esult in an immediate switching off of the filter pump the dosing equipment and the heating The closing of one of the contacts between clamps 2 and 4 or 11 and 12 will cause a forced switch on of the...

Страница 5: ...ect operating mode Pilot light operating mode Set time Interrogate soalr temperature Pilot light solar operation Pilot light heating Heating ON OFF LCD display Adjustment buttons LCD display 23 4 14 4...

Страница 6: ...by the colour of the light green The temperature control is running the selected water temperature has been reached yellow The heating is running the selected temperature has not been reached yet red...

Страница 7: ...ow be set 3 Press again the display will show 0 00 OFF 1 4 By pressing the and keys the requested off period can now be set 5 Press key again the display will show ON 2 6 Additional switching times ca...

Страница 8: ...fuse on the circuit board The short circuit protection for the filter pump has to be ensured by customer provided pre fuses of max 16A Electronic motor protection 22 23 30 31 32 33 Heating Motor Water...

Страница 9: ...nput 0 l Mains230V 1 N PE 11 12 13 14 4 7 6 5 8 U1 N N L1 Solenoid valve 230V Water level 3 N PE EUROTRONIK 10 Motor protect contact Filterpump temperature probe heating pump W Mains 400V chemical con...

Страница 10: ...Operating Instructions PC 25 page 10 10...

Отзывы: