Functionality of the Main Menu
32
Items
Default
Value
Domain Range
Description
G1+G2
G1+G3
G1+G4
G2+G3
G2+G4
G3+G4
G1-G4
METER
DIRECTION
VERTICAL
VERTICAL
HORIZONTAL
Select the displayed
direction of audio meter.
METER
POSITION
BOT
LEFT/
BOTTOM
When the value of METER
DIRECTION is VERTICAL
, you can choose the
followings
for
Meter
Position:
BOT LEFT: bottom left
BOT RIGHT: bottom
right
TOP RIGHT: top right
TOP LEFT: top left
When the value of METER
DIRECTION
is
HORIZONTAL, you can
choose the followings for
Meter Position:
BOTTOM
TOP
Select the displayed
position of audio meter.
METER DIS
MODE
MODE1
MODE1: simple audio
meter
MODE2: audio meter
with channel number
MODE3: audio meter
with channel number
and dB value
Select the displayed
mode for audio meter.
REF LEVEL -20dB
-20dB/-18dB
Select the reference
level
OVER
LEVEL
-10dB
-10dB
-8dB
-6dB
-4dB
-2dB
Select the overload level