Oscartielle MINOR 2000 Series Скачать руководство пользователя страница 13

 

 

18 

ENGLISH 

 
1 - Description of the unit 

The MINOR2000 line of display cabinets are built-in units with a usable internal length of 620mm (MODEL 70), 900mm 
(MODEL  100),  1188mm  (MODEL  130),  1800mm  (MODEL  190),  2376mm  (MODEL  250),  in  the  versions  for  deli/dairy 
products, packaged fruit/vegetables and packaged meats. All these cabinets can be multiplexed and are equipped with a 
built-in condensing unit, with fan assisted cooling. FIG. 1 illustrates the general appearance and dimensions of these units 
in detail. 
 

2 - Handling the unit 

This  furniture  item  has  plastic  feet  (FIG.  4.1)  or  wooden  pallets  (FIG.  4.2)  for  cage  packaging  (on  request)  to  allow 
handling by a forklift truck. Only authorised technicians should handle the unit. 
TAB.1 and FIG. 2 shows the weight of the units in the different lengths and relevant lifting points. 
 

3 - Receipt and storage 

On  delivery,  check  that  the  unit  hasn't  been  damaged  during  transport.  Check  the  condition  of  the  packaging:  if  the 
packaging is damaged, check the contents in the presence of the carrier. 
For storage,  make  sure that the  unit is  protected  against  the  weather  and stored  at a temperature  between -25°C  and 
+55°C; 30-95% relative humidity. 
Take  special  care  when  unpacking  the  unit,  as  the  packaging  contains  various  parts  and/or  accessories  needed  to 
complete the display unit  (spacers, raised edges, etc). 
Remove  the  plastic  feet  from  the  unit  (FIG.  4.1)  or  wooden  pallets  (FIG.  4.2)  and  remove  the  transparent  perimeter 
protection. 
Place the display unit exactly where you want to install it. Move the unit properly: 

never drag by its sides!

 

Warning:

  Inform  the  Manufacturer  immediately  if  the  unit  arrives  damaged.  Any  delay  in  doing  so  relieves  the 

Manufacturer of all liability.  
The Manufacturer is not liable for any damage to the unit during handling and storage. 
 

4 - Installation and environmental conditions 

Disconnect the cabinet from the square and from the packaging and screw the adjustable feet. (Fig. 4.2.B).

 

The  unit  must sit  on  a  perfectly  levelled   floor. When fully  loaded, the display  unit should not vibrate  (see  FIG.  5).  The 
efficiency of the unit may be compromised if this isn't perfectly level! 
The display unit must never be placed in areas where explosive gas substances are used. 
The unit should not be left outdoors or exposed to the rain (see FIG. 3). 
The  performance  of  the  cabinet  refers  (according  to  the  international  standard 

EN  ISO  23953-1/2

)  to  environmental 

climatic class 3 which consists of a room temperature of 25°C with relative humidity of 60%. 
Sufficient space must be provided to guarantee good air circulation for the condenser (see FIG. 9). Do not place objects 
in  front  of  the  condenser  protection  grid,  as  this  could  compromise  the  efficiency  of  the  refrigerated  display  unit  (see 
FIG.6).  The  performance  will  be  less  than  expected  if  the  environmental  conditions  differ  from  those  foreseen,  or  the 
display units are exposed to air flows of more than 0.2m/sec or heat radiation.  
To avoid this problem, the User should send the Manufacturer details of the environmental conditions before finalising the 
design of the units, so that the technical parameters and material options can be modified and the installer be informed of 
the refrigerating power actually required. 
 

5 - Electrical connections 

Important: installation should be made following the manufacturer's instructions, by qualified personnel only, in conformity 
with the electric safety regulations in force. Please refer to the electrical diagram on FIG.16.1 and FIG.16.2. 
At the input of the supply it is necessary to install an omni-polar magnetothermic/differential device with contact opening 
equal to 3 mm and adequate cut-off power. 

Warning:

 Before connecting the unit to the mains, make sure that the mains voltage corresponds to that indicated on the 

serial plate (bearing in mind that the max acceptable variations in voltage are +/-10%). Check that the cable used has the 
right  cross-section  and  length  to  withstand  the  current  and  the  power  absorbed  by  the  combination,  as  indicated  in 
TAB.2.1, TAB.2.2. 
The plug-in cabinets (except for Minor 2000 L250) are supplied already fitted with a cable m. 2,5 long and a plug (FIG.7). 
The plug has to be inserted into a fix socket, without using further extension, multiple outlet or longer cables.  
The plug-in cabinets Minor 2000 L250 are are supplied already fitted with a cable m. 2,5 long without plug. Therefore it is 
necessary  to  have  an  industrial  plug  (according  to  standard  IEC309  for  16  A)  assembled  on  the  supplied  cable  by 
qualified personnel. Then plug into an industrial socket (according to standard IEC309 for 16 A) without using any further 
extension, multiple outlet or longer cables. 
The cable should be fully extended and located where it's unlikely to hit, caught or trod upon, away from water and other 
liquids and  heat sources and must not be damaged. In case of breakage of the power cable of the cabinet, it must be 
replaced by the manufacturer or by  institution  in  charge of  it. The plug  must  still  be accessible  even  after installing  the 
unit. 

Содержание MINOR 2000 Series

Страница 1: ...MINOR 2000 INSTRUCTION MANUAL BETRIEBSANLEITUNG INSTRUCCIONES DE USO...

Страница 2: ...uel Au cas o l acqu reur du meuble frigorifique ne comprendrait pas une quelconque instruction mentionn e dans ce manuel d utilisation il est pri de s adresser au service apr s vente Oscartielle Oscar...

Страница 3: ...obile Cabinet handling Transport du meuble Transport des K hlm bels Desplazamiento de la c mara MINOR2000 70 100 130 190 250 Lunghezza Length mm 620 900 1188 1800 2376 Peso Weight kg 150 185 220 290 4...

Страница 4: ...e condizioni ambientali Installation and environmental conditions Installation et conditions ambiantes Inbetriebnahme und Einsatzbedingungen Instalaci n y condiciones ambientales FIG 3 FIG 5 FIG 4 1 B...

Страница 5: ...a W Absorbed Power W 933 1049 1303 1765 2629 Potenza assorbita W in sbrinamento elettrico Optional Absorbed Power W in electric defrost Optional 194 197 268 416 559 Working temperature 0 C 2 C 5 C 7 C...

Страница 6: ...4 Messa in funzione e caricamento Start up and loading Mise en marche et chargement Inbetriebnahme und Best ckung Puesta en servicio y carga FIG 9 FIG 10 FIG 11 FIG 12...

Страница 7: ...5 E A B C D Manutenzione del mobile Unit maintenance Entretien du meuble Wartung Mantenimiento de la c mara FIG 14 FIG 13...

Страница 8: ...6 Canalizzazione del mobile Multiplexing Canalisation du meuble Zusammenbau Ensamblaje de c maras FIG 15...

Страница 9: ...7 Schema elettrico Electrical diagram Sch ma lectrique Schalt plan Esquema el ctrico FIG 16 1 G I L70 100 130 190 e G E L70 100 130 190 250...

Страница 10: ...8 Schema elettrico Electrical diagram Sch ma lectrique Schalt plan Esquema el ctrico FIG 16 2 G I L250...

Страница 11: ...way the first instrument controls the defrosts of all multiplexed cabinets 2 In order to synchronize the defrosts in a line up of two or more refrigerated cabinets set the parameter i0 6 on the first...

Страница 12: ...ve Conectar el Faston n 8 del cuadro master con el faston n 8 del cuadro slave De esta manera el primero instrumento comanda los desescarches de los meubles en canal 2 Para sincronizar los desescarche...

Страница 13: ...class 3 which consists of a room temperature of 25 C with relative humidity of 60 Sufficient space must be provided to guarantee good air circulation for the condenser see FIG 9 Do not place objects...

Страница 14: ...ped during positioning and installation wait at least three hours before starting it up in order to give the lubricating oil enough time to collect in the compressor The refrigerating unit may be irre...

Страница 15: ...to melt when the defrost cycle is on These heating elements are optional and are supplied on request The number of defrost cycles standard is 4 cycles every 24 hours is set in the factory Check period...

Страница 16: ...ed in foam polystyrene for thermal insulation of the cabinet is CO2 This product contains HFC namely fluoridated gasses a refrigerating gas with a high Global Warming Potential GWP regulated by the Ky...

Страница 17: ...m Fan motor Vv Display case fan 18 Instructions for the defrosts synchronization of multiplexed cabinets with instrument EVZ000 Please refer to the explanation at page 9 The connecting cable is suppli...

Страница 18: ...f The following personal protective equipment are compulsory for technicians who work on the counter Symbol Description Eyes protection Protective gloves Safety Shoes Safety Symbols for immediate noti...

Страница 19: ...and recycling of professional WEEE RAEE In case of trade in of the old product for a new one the user can ask the seller to take delivery of the old one no matter what the brand The manufacturer is r...

Отзывы: