4.4. Installing

To ensure high-quality operation of the detector, the next principals recommended during in-

stallation:

Place the magnet near the marked side of the detector housing;

Do not install the detector on metal surfaces;

Provide a distance of at least 10 mm from metal structures to the detector or magnet;

Avoid shock and other mechanical influences on the detector and magnet during opera-

tion.

5. Maintenance

Detector does not require any maintenance.

6. Operating conditions

1. Detector is designed for continuous operation.
2. Detector shall be used at the temperature of –20°С to +55°С and relative humidity of 5% to

85%.

3. If the transportation conditions differ from the operating conditions, then the detector must

be kept in the operating conditions for 2…6 hours before switching on.

7. Storage

1. Storage temperature shall be of –50°C...+55°C at the relative humidity of 5% up to 98%.

2. During handling operations, transportation and storage in warehouses, boxes with detectors

shall not be exposed to sharp bows. Stacking and fixing of the boxes to the transporter shall

not include their movement.

3. Detector shall be stored in the manufacturer's package. Battery must be removed for the en-

tire storage period or insulator must be installed in the battery holder.

8. Transportation

1. Detector transportation shall be carried out in the manufacturer's package.

2. Detector is allowed to be transported by all types of enclosed transporters, subject to ob-

serving the shipping rules applicable for each type of transport.

3. Transportation temperature shall be of –50°C to +50°C at the relative humidity of 5% up to

98%.

9. Disposal

Detector disposal shall be carried out according to electronic household appliance disposal

rules established by the legislation of the State, where the product is operated.

Magnet-R

Version en_2

6

Содержание Magnet-R

Страница 1: ...ith operating modes and conditions therefore this document requirements is mandatory Magnetic Contact Detector Magnet R Operation manual ORTUS Group Product Compatibility Table Compatible radio receiv...

Страница 2: ...3 3 Technical specifications 3 4 How to use 4 4 1 Modes Indication 5 4 2 Binding 5 4 3 Wireless signal strength 5 4 4 Installing 6 5 Maintenance 6 6 Operating conditions 6 7 Storage 6 8 Transportatio...

Страница 3: ...nd repair The device does not have open live parts representing the danger of electric shock to a per son No safety ground 3 Technical specifications The detector technical characteristics is shown in...

Страница 4: ...e detector is generated If the magnet is moved away from the housing or moved away from the marked position the reed switch opens and detector generates an alarm event If the housing cover is opened t...

Страница 5: ...ogramming manual 4 Install the battery to the detector observing polarity 5 Switch the detector to the binding mode by short circuit the RESET contacts for 2 3 sec onds until the blinking green the si...

Страница 6: ...temperature shall be of 50 C 55 C at the relative humidity of 5 up to 98 2 During handling operations transportation and storage in warehouses boxes with detectors shall not be exposed to sharp bows S...

Страница 7: ...Manufacturer ORTUS Group 1 East Liberty 6th Floor Reno NV 89501 USA Tel 1 650 240 27 62 mail info ortus io http www ortus io Magnet R Version en_2 7...

Отзывы: