4.4. Installing
To ensure high-quality operation of the detector, the next principals recommended during in-
stallation:
●
Place the magnet near the marked side of the detector housing;
●
Do not install the detector on metal surfaces;
●
Provide a distance of at least 10 mm from metal structures to the detector or magnet;
●
Avoid shock and other mechanical influences on the detector and magnet during opera-
tion.
5. Maintenance
Detector does not require any maintenance.
6. Operating conditions
1. Detector is designed for continuous operation.
2. Detector shall be used at the temperature of –20°С to +55°С and relative humidity of 5% to
85%.
3. If the transportation conditions differ from the operating conditions, then the detector must
be kept in the operating conditions for 2…6 hours before switching on.
7. Storage
1. Storage temperature shall be of –50°C...+55°C at the relative humidity of 5% up to 98%.
2. During handling operations, transportation and storage in warehouses, boxes with detectors
shall not be exposed to sharp bows. Stacking and fixing of the boxes to the transporter shall
not include their movement.
3. Detector shall be stored in the manufacturer's package. Battery must be removed for the en-
tire storage period or insulator must be installed in the battery holder.
8. Transportation
1. Detector transportation shall be carried out in the manufacturer's package.
2. Detector is allowed to be transported by all types of enclosed transporters, subject to ob-
serving the shipping rules applicable for each type of transport.
3. Transportation temperature shall be of –50°C to +50°C at the relative humidity of 5% up to
98%.
9. Disposal
Detector disposal shall be carried out according to electronic household appliance disposal
rules established by the legislation of the State, where the product is operated.