USER MANUAL INDEX
Smart Controller
MODEL
ODD
MF-ST
Instruction Manual
Temperature Alarm
(cont'd)
•
To access the
TEMPERATURE ALARM
setup, when the controller is powered
OFF
(and connected to the fan), press and hold the
UP
arrow button for 3 seconds.
Press the
UP
or
DOWN
arrows to select the temperature in which you would like
the alarm to be triggered. Once you've selected the
TEMPERATURE ALARM
trigger
level, press the
POWER
button to save it and power
ON
the controller.
•
Once the controller is powered
ON
, activate the
TEMPERATURE ALARM
feature by
pressing and holding the
MODE
and the
DOWN
arrow buttons simultaneously until
the
BELL
icon illuminates on the controller's screen.
•
To deactivate the
TEMPERATURE ALARM
feature, press and hold the
MODE
and
the
DOWN
arrow buttons simultaneously until the
BELL
icon disappears from the
controller's screen.
Fan Failure Detection and Error Messages
•
EC fans send frequent tachometer signals to the controller. These signals are used
to detect fan failures and alert the user by beeping and displaying error
notifications
•
To use this feature, please make sure to connect your fans to consecutive OUT
ports on the controller. For instance, if you run 1 fan only then connect it to OUT1
port. If you run 2 fans on the same controller, then connect them to OUT1 and
OUT2 ports. Similarly, if you run 3 fans on the same controller, then connect them
to OUT1, OUT2 and OUT3 ports. If one of the OUT ports won't have a working fan
connected to it, but the alerts for that port are activated, it will result in false error
alerts. Only activate these alerts for the number of OUT ports currently in use.
•
To activate the fan failure detection and error alerts features, when the controller is
powered
OFF
(and connected to the fan), press and hold the
DOWN
arrow button
for 3 seconds. Using the
UP
and
DOWN
arrows, select a number from 0 to 4 to
match the amount of fans currently connected to controller's OUT ports.
•
0-This mode indicates that fan failure detection is disabled for all ports.
•
1-This mode indicates that fan failure detection is enabled on port OUT1.
•
2-This mode indicates that fan failure detection is enabled on ports OUT1 and 2.
•
3-This mode indicates that fan failure detection is enabled on ports OUT1,2 and 3.
•
4-This mode indicates that fan failure detection is enabled on ports OUT1,2,3, and 4
•
If your controller is connected to 4 EC fans and the fan connected to OUT1 port
becomes disabled, the controller will beep and display error message "E1"
indicating the problem is on port OUT1. Similarly, "E2" will indicate failure of the fan
on port OUT2, "E3" will indicate failure of the fan on port OUT3 and "E4" will
indicate failure of the fan on port OUT4. If multiple fans will fail at the same time,
multiple error messages will be displayed in sequence.
•
Error message, Er', indicates a connection problem with the thermal probe. The
smart controller cannot operate without a working thermal probe.