Unit Installation

Installation 

B

b3

Hang the one side of the unit on the screws mounted on the

a1) 

truss. Lift the other side of the unit and secure it to the other

a1) 

truss. Mount the unit to the truss using 2 screws per bracket.

b4

After installation, the bottom of the unit is in contact with the

a2) 

bottom of the ceiling.

DUCTWORK

screws

screws

21-1/4" to 23"

(539.8mm to

584.2mm)

1-1/16"

(27mm)

1/2"

(12.7mm)

For Houses 

WITHOUT

 Ducted Heating or Cooling Systems (see Fig.2)

In most houses, 

one or two fresh air grilles in a central part of the house provide effective distribution of the fresh air into the home, particularly 

when the stale exhaust air is picked up at several points. Because the fresh air is usually somewhat cooler than the indoor air, the fresh air 

supply grilles should be located in a traffic area like a hallway or stairway rather than in a sitting area. If you want to get fresh air into specific 

room with high occupancy, you can split up the fresh air supply.

For Houses 

WITH Forced-air Heating and Cooling Systems

 (see Fig.

1, Fig.3, and Fig4

)

Most units are installed with the fresh air duct connected directly to a return duct for the main heating and cooling system.

Make sure to connect the fresh air duct at least 3 feet from the return plenum to minimize suction from the furnace blower. A connection closer 

to the furnace may result in unbalanced flow or other associated problems.

For Installations that Collect Stale Air from Specific Rooms in the Home (see Fig.1 and Fig.2)

Locate stale air return grilles (RA) in rooms where moisture and odors are generated: bathrooms, kitchens, and perhaps areas where 

contaminants may be generated such as the home workshop. Return grilles in these areas such as the home workshop may be dampered so 

that they can be shut off when not in use. A central location such as a hallway is also acceptable, but it would not clear humidity and odors from 

baths and kitchens quickly. Locate stale air return grilles (RA) near the ceiling on inside walls. Stale air returns are usually easiest to install in 

interior partitions.

Содержание OD-ERV 150AC

Страница 1: ...rces of hazardous air such as auto exhausts 8 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment is located take steps to assure that combustion air supply is not affected Follow the heating equipment manufacturer s requirements and the combustion air supply requirements of applicable codes and standards 9 When cutting or drill...

Страница 2: ...he energy exchange core stays clean even if the core faces are covered with dust CAUTION DO NOT WASH THE ENERGY EXCHANGE CORE The energy exchange core can be replaced but is expensive The core is secured to the unit by the core latch when the unit is installed as installation B If the core latch is disengaged the core can fall out causing damage or injury if not prepared after the door swinging do...

Страница 3: ... check cycle The orange L2 LED indicator light will illuminate continuously The check cycle will run the RA fan for 5 minutes at full speed every 15 minutes 25 of every hour in order to minimize frost on the core and meet code requirements The OA fan will not run during this check cycle The HVAC AHU blower if connected will NOT run during this check cycle to prevent cycling The MOS will still boos...

Страница 4: ...tion of the HVAC system in a residence the speed controls should be re calibrated for optimum performance If the residence undergoes significant structural changes such as an addition to the home the unit should also be re calibrated If optional MERV 13 filters are installed recalibration is also required The unit provide the ability to deliver completely balanced airflows or to modify them as des...

Страница 5: ...nit in an attic or other unconditioned space all of the unit s ductwork that is located in the attic MUST be insulated Use at least R 6 insulation INSTALLATION GUIDE CAUTION RISK OF INJURY WHEN LIFTING AND INSTALLING UNIT OVERHEAD Get a helper and wear eye protection and gloves Locate the unit for the simplest duct layout and connections Note that the door is equipped with hinges For the homeowner...

Страница 6: ...a hallway or stairway rather than in a sitting area If you want to get fresh air into specific room with high occupancy you can split up the fresh air supply For Houses WITH Forced air Heating and Cooling Systems see Fig 1 Fig 3 and Fig4 Most units are installed with the fresh air duct connected directly to a return duct for the main heating and cooling system Make sure to connect the fresh air du...

Страница 7: ...mneys furnace and water heater exhausts or other sources of contamination or carbon monoxide NEVER locate the fresh air inlet inside a structure Installing Return Air RA Ducts All the stale air returns are connected by ducts to the unit Generally empty stud cavities are used for returns as is often done with cold air returns for the furnace using standard duct boots to connect to six inch pipe at ...

Страница 8: ...he HVAC AHU 24V AC dry contact relay to the terminal block so that when the ERV is operating the HVAC AHU blower operates to help distribute the fresh air through the existing ductwork if needed The unit has an optional terminal block for a MANUAL OVERRIDE SWITCH MOS connection Connect an ON OFF switch to the terminal block to manually switch the unit to high speed When the switch is off the unit ...

Отзывы: