ORPHEUS ONE SE MK2 Скачать руководство пользователя страница 6

 

 

ORPHEUS ONE SE 

O P E R A T I O N S    

QUICK GUIDE 

CONNECTION 

Connect the digital (input-) cable first, followed by 
the analogue (output-) ones and finally the power 
cord. 

POWER ON 

Flip the main power switch on the right hand side 
of rear panel. 

DIGITAL DATA STREAM  

Select  between  AES/EBU,  S/PDIF,  BNC  or 
TOSLINK  digital  input  data  formats,  according  to 
your digital source and the connection choosen.  

The  display  will  (for  approx.  two  seconds)  show  

44,1         192  

when the system has locked onto 

the incoming digital data stream. If the system is 
unable  to  lock  onto  the  incoming  digital  data 
stream,  the  display  shows 

NO  LOCK.   

Please 

check your source is sending data and make sure 
it is connected correctly to the input  choosen. 

NO 

PCM

 indicates that a non linear PCM data stream 

is recieved from for example a DTS CD. 

BURN-IN TIME 

The unit needs approximately fifty hours of burn-
in time to develop its full potential. 

ORPHEUS ONE SE is a 2 channel 24bit/192kHz 
upsampler  and  digital  to  analogue  conversion 
unit. 

ORPHEUS ONE SE features Anagram Technolo-
gies software based Quantum™ sample rate con-
version technology. Each incoming data stream is 
converted  into  a  high  definition  24bit/192kHz  si-
gnal prior to being converted to the analogue do-
main. The complexity of the analogue reconstruc-
tion  filter  is  significantly  reduced  by  using  a  192 
kHz  sampling  rate.  This  results  in  near  perfect 
phase linearity and soundstage quality. 

ORPHEUS  ONE  SE  features  a  modular  layout. 
The unit’s upsampling module, or the whole digital 
section,  can  be  changed  in  the  future  and  thus 
adapted to new technologies and data formats. 

 

The USB expansion allows the user to connect a 
PC/MAC  to  the  Orpheus  One  SE  and  use  it  as 
sound  card.  You  can  now  listen  to  your  music 
from  your  computer  using  the  conversion  quality 
of  your  Orpheus  D/A  Converter.  The  audiocard 
functions at 24 bits @ 96kHz.  

 

 

 

 

 

TECHNICAL DATA 

Digital  input  :  one  S/PDIF,  75  Ohm,  0.5  V,  on 
RCA  connector  and  one  AES/EBU,  110  Ohm,  5 
V, on XLR connector, USB  

Analogue output : either balanced, 4.2 V rms, on 
XLR connectors or unbalanced, 2.1 V rms, on 
RCA connectors 

Impedance : 75 Ohm 

24 bit / 44.1 kHz input signal : 

Harmonic distortion (THD+N) : 

-109dBr 

0 dB FS 

 

Dynamic (THD+N @ -60 dB FS) :  120 dBr 

Signal to noise ratio : 

121 dBr 

Residual noise 20 Hz to 22 kHz : 

3.6 

V  @  4.2 Vrms balanced 

1.8 

V  @  2.1 Vrms unbalanced 

Frequency response : set for optimal transient 

response 

Содержание ONE SE MK2

Страница 1: ...ORPHEUS ONE SE MK2 U S E R M A N U A L...

Страница 2: ...e of heat Avoid also locations subject to vibration and excessive dust heat cold or moisture To reduce the risk of fire or electric shock do not expose the unit to rain or moisture Do not use force wh...

Страница 3: ...for selecting options menus and inputs SELECT Used for entering set up menu structure and ac cessing menu options as well as confirming choices and settings 1 MAIN POWER INDICATOR Lights red when the...

Страница 4: ...and 2 for S PDIF format 3 INPUTS BNC FORMAT Digital data stream inputs using two indepen dent connectors BNC 1 and 2 for BNC for mat 2 3 6 USB SLOT USB connector 7 POWER SUPPLY Power cord connection...

Страница 5: ...nced input with RCA connector connect pin 1 to ground and pin 2 to signal and make sure pin 3 is not used ORPHEUS ONE SE 5 C O N N E C T I O N S R right channel L left channel R L B T A AES EBU S S PD...

Страница 6: ...version technology Each incoming data stream is converted into a high definition 24bit 192kHz si gnal prior to being converted to the analogue do main The complexity of the analogue reconstruc tion fi...

Страница 7: ...E ORPHEUS ONE SE DA CONVERTER AES EBU 44 1 192 SETUP STANDBY SETUP PREFERENCES SETUP DISPLAY SETUP KEY REPEAT RATE SETUP PHASE SETUP NAMES 1 10 8 7 6 5 4 SPDIF 1 2 Options AES EBU SPDIF 1 or 2 BNC 1 o...

Страница 8: ...wer is switched on It is then replaced by the main screen ORPHEUS ONE SE DA CONVERTER 1 AES EBU 2 MAIN SCREEN The main screen is the default display during nor mal operation It shows the name of the d...

Страница 9: ...Press or v to change the value Characters A to Z and 0 to 9 as well as space are available RENAMING Each input can have any individually defined name The name can be a word with a combina tion of up t...

Страница 10: ...personal settings need to be saved before turning off main power It is possible to restore previously stored settings as well as calling back the initial factory settings Options SAVE RESET FACTORY SE...

Страница 11: ...conceived by Orpheus Media S rl IMPORTANT NOTICE Orpheus Media S rl reserve the right to make changes to their products or discontinue any pro duct or service without notice Adequate operating safegu...

Отзывы: