9
INSTALLATION
1. Remove the back cover from the keypad using the supplied allen key.
2. Drill two holes on the wall (A, C) for the self-taping screws and one hole for the cable.
3. Put the supplied plastic anchors into two holes (A, C).
4. Fix the back cover firmly on the wall with two self-taping screws.
5. Put the cable through the cable hole (B).
6. Attach the device to the back cover.
FEATURES
•
Waterproof, compliant with IP66
•
Robust and resistant zinc alloy housing with protective coating
•
Full keypad programming possible
•
Memory for 1000 users
•
Can be used as a separate keypad
•
Backlit keypad (automatically off after 20 seconds)
•
EM 125kHz proximity card and tag reader
•
Wiegand 26 type input for connection to an external reader
•
Wiegand 26 type output for connection to the controller
•
Adjustment of the door strike opening time
•
Short-circuit protection of the electric striker
•
Easy installation and programming
•
Tri-color LED status display
•
Built-in buzzer
Programming mode - Quick guide
Enter the programming mode
* Main code #
123456 is the default main code
Exit the programming mode
*
Change the main code
0 New code # New code #
The main code may contain from 6 to 8 digits.
Add PIN user
1 PIN #
The PIN may contain any four digits from 0000 to 9999, except for the combination 8888, which
is reserved.
Add card user
1 Read card #
Cards can be added consecutively without having to leave programming mode.
Delete users
2 PIN # for PIN user or
2 Read card # for card user
Door opening for PIN user
Input PIN code next press #
Door opening for card user
Read card
Wiring connection
Color
Functions
Description
Red
DC+
12VDC Input power
Black
GND
Negative supply pole
Blue-black
NO
Door relay NO contact (potential free)
White-black
COM
Common contact for door open relay (potential free)
Green-black
NC
Door relay NC contact (potential free)
Yellow
OPEN
Exit button one end (the other end connected to GND)
Green
D0
WG output D0
White
D1
WG output D1
Grey
ALARM
Negative contact for Alarm
Brown
D_IN
Door status sensor NC (the other end connected to GND)
Brown-black
Doorbell A
Doorbell A connection
Yellow-black
Doorbell B
Doorbell B connection
Sound and light indication
Operation status
Red light
Green light
Orange light
Buzzer
Stand by
bright
-
-
-
Enter into programming mode
flashes
-
-
One beep
Operation in programming mode
bright
-
bright
One beep
Operation failed
flashes
-
-
3x beep
Exit from the programming mode
flashes
-
-
One beep
Door opening
-
bright
-
One beep
Alarm
flashes
-
-
Alarm