CAUTION! 

 

When MV equipment is operating, certain components are live, other parts may be in movement and some may reach high 
temperatures. Therefore, the use of this equipment poses electrical, mechanical and thermal risks. 
 
In order to ensure an acceptable level of protection for people and property, and in compliance with applicable environmental 
recommendations, Ormazabal designs and manufactures its products according to the principle of integrated safety, based on 
the following criteria: 
 

 

Elimination of hazards wherever possible. 

 

Where elimination of hazards is neither technically nor economically feasible, appropriate protection functions are 
incorporated in the equipment. 

 

Communication about remaining risks to facilitate the design of operating procedures which prevent such risks, 
training for the personnel in charge of the equipment, and the use of suitable personal protection equipment. 

 

Use of recyclable materials and establishment of procedures for the disposal of equipment and components so 
that once the end of their useful lives is reached, they are duly processed in accordance, as far as possible, with 
the environmental restrictions established by the competent authorities. 

 
Consequently, the equipment to which the present manual refers complies with the requirements of section 11.2 of the 
forthcoming IEC standard

 

62271-1. It must therefore only be operated by appropriately qualified and supervised personnel, in 

accordance with the requirements of standard EN 50110-1 on the safety of electrical installations and standard EN 50110-2 on 
activities in or near electrical installations. Personnel must be fully familiar with the instructions and warnings contained in this 
manual and in other recommendations of a more general nature which are applicable to the situation according to current 
legislation.  

 

The above must be carefully observed, as the correct and safe operation of this equipment depends not only on its design but 
also on general circumstances which are in general beyond the control and responsibility of the manufacturer. More specifically: 
 

 

The equipment must be handled and transported appropriately from the factory to the place of installation. 

 

All intermediate storage should occur in conditions which do not alter or damage the characteristics of the 
equipment or its essential components. 

 

Service conditions must be compatible with the equipment rating. 

 

The equipment must be operated strictly in accordance with the instructions given in the manual, and the 
applicable operating and safety principles must be clearly understood. 

 

Maintenance should be performed properly, taking into account the actual service and environmental conditions 
in the place of installation.

 

 
The manufacturer declines all liability for any significant indirect damages resulting from violation of the guarantee, under any 
jurisdiction, including loss of income, stoppages and costs resulting from repair or replacement of parts. 
 
Guarantee 

 

The manufacturer guarantees this product against any defect in materials and operation during the contractual period. In the 
event that defects are detected, the manufacturer may opt either to repair or replace the equipment. Improper handling of this 
equipment and its repair by the user shall constitute a violation of the guarantee. 
 
Registered Trademarks and Copyrights 

 

All registered trademarks cited in this document are the property of their respective owners. The intellectual property of this 
manual belongs to the manufacturer.  

 
 

In view of the constant evolution in standards and design, the characteristics of the elements contained in this manual are 
subject to change without prior notification. 
 
These characteristics, as well as the availability of components, are subject to confirmation by Ormazabal’s Technical - 
Commercial Department.

 

 

 

Содержание CMS-17

Страница 1: ...B version 01 Secondary Distribution Switchgear Primary Distribution Switchgear Protection and Automation Distribution Transformers Transformer Substations Low Voltage Boards LIB 11 08 2011 CMS 17 SWIT...

Страница 2: ...uation according to current legislation The above must be carefully observed as the correct and safe operation of this equipment depends not only on its design but also on general circumstances which...

Страница 3: ...ical Equipment 9 2 TRANSPORT 10 2 1 LIFTING METHODS 10 2 2 ACCESS 11 2 3 OVERLAND TRANSPORT 11 2 4 SEA TRANSPORT 12 2 5 DELIVERY CONDITIONS 12 3 INSTALLATION 13 3 1 LOCATION 13 3 2 PLANNING 13 3 3 EXC...

Страница 4: ...been designed in accordance with standard EN 62271 202 to be used in public electrical distribution networks of up to 24 kV 1 Interior switchgear 1 1 MV switchgear CGMCOSMOS system 2 Prefabricated Con...

Страница 5: ...owing components Switchgear unit formed by up to 4 MV feeder functions completely insulated in SF6 with an insulation voltage of 24 kV b Switching and Breaking Substation with Protection units made up...

Страница 6: ...ch disconnector IEC 60265 1 Type Rotation category E3 Rated current A 400 630 Rated short time withstand current kA 16 eff 1 s Peak value kA 40 Short circuit making capacity kA 16 40 N of short circui...

Страница 7: ...ng to the Switching and Breaking Substation Cable entry and exit holes four at the bottom of the enclosure with a diameter of 174 mm Additionally the substation also has 400 x 132 mm cable exit holes...

Страница 8: ...nsions and weights of the CMS 17 Switching and Breaking Substation are given below 1 3 1 Concrete Enclosure Dimensions Total 2080 Height Visible mm 1600 Width mm 2170 Depth mm 1310 Figure 1 5 Enclosur...

Страница 9: ...ion 01 11 08 2011 1 3 2 Electrical equipment Dimensions 4L 2L2P Height mm 1300 Width mm 1460 4 x 365 mm 1670 2 x 365 mm 2 x 470 mm Depth mm 735 Weight 4L 2L2P Weight kg 344 4 x 86 kg 430 2 x 86 kg 2 x...

Страница 10: ...Switching and Breaking Substation has 4 DEHA type inserts 6000 2 0170 which enable it to be handled using the proper lifting beam slings and hooks in order to guarantee a hoisting as balanced as poss...

Страница 11: ...s etc 2 3 OVERLAND TRANSPORT Transportation should be carried out using a truck The CMS 17 Switching and Breaking Substation electrical equipment is supplied screwed onto the rails located on the floo...

Страница 12: ...tainer attach a 100 x 100 x 10 mm and 100 mm long square to each corner of the building They must be welded to the floor of the container in order to avoid any movement during transportation Lastly pl...

Страница 13: ...ect that could impede or obstruct the smooth operation of the installation must be indicated posts cables ditches walls pipelines etc marking their positions on the drawing with the corresponding meas...

Страница 14: ...inside As a general rule maintain a 3000 mm area around the excavation free of materials and vehicle traffic In the case of rain and puddles carefully inspect the excavation using qualified technician...

Страница 15: ...ith the external earthing network 3 5 EARTH CONNECTION The CMS 17 Switching and Breaking Substation has an internal earthing circuit to facilitate the connection of the different elements to the earth...

Страница 16: ...The copper braid cross section the terminations contact surface and the tightening torques must be suitable for a fault current delimited by network protections It is recommended an external protectiv...

Страница 17: ...level 0 even underneath the enclosure itself To open a hole simply knock it inwards with a hammer Then clean the pieces of concrete from inside the enclosure The MV cables must meet the minimum radius...

Страница 18: ...are specified in Ormazabal s IG 078 General Instructions document which is supplied with the CMS 17 5 MAINTENANCE The requirements set out in the applicable legislation on Transformer Substations to...

Страница 19: ...ng them at 90 and 180 To unlock the system pull upward on the rod a and open the corresponding door b Disconnect the power to the Electrical Equipment switching the MV switchgear unit to the earthing...

Страница 20: ...ve the cover and place it on top of wooden planks a Figure 5 4 Hoisting Eyebolts Figure 5 5 Positioning on the planks f Open the MV switchgear cable compartment lid 4 Disconnect the power cables and t...

Страница 21: ...the right cubicle h Unscrew the MV switchgear fixing points a on the rails that are arranged over the base of the Switching and Breaking Substation i Extract the electrical equipment To do this the us...

Страница 22: ...Connect the electrical equipment s earth connection to the MV switchgear earthing bar n Re connect the MV cables that supply power to the MV switchgear o Re attach the removable cover p Once the cove...

Страница 23: ...sent with the concrete enclosure First aid sign Electrical warning sign Lever for actuating the MV switchgear CMS 17 Switching and Breaking Substation General Instructions IG 178 CGMCOSMOS Cubicle Sy...

Страница 24: ...Page 24 of 20 TECHNICAL COMMERCIAL DEPARTMENT www ormazabal com...

Отзывы: