1. Temperatures range
-9 °C +99 °C
2. Temperatures settings
+60 °C do +97 °C
3. Pump temperatures range
+65 °C do +90 °C
4. Blow-through settings
work time
0-90 seconds
pause
1-15 minutes
Blow-through turn off
P-0
5. Hysteresis
od 2 °C do 9 °C
6. Input power:
fan
100 W
pump
100 W
7. Voltage AC
230 V AC, 50 Hz
8. Input volatge
275 VA
9. Fan power in percentages % x 10
(setting range 30 % to 100 %)
10. Relative air temperature
≤95 %
11. Protection class
IP 40
12. Insulation class
I
13. Ambient temperature
0-40 °C
14. Disconnection type
full
15. Electric protection
2 x 1.25 A (fusible)
2. Technical data
2.1. EKOSTER 2 – technical data
2.2. EKOSTER 2 – installation recommendations
1. Controller is adjusted to cooperate with solid fuel boilers.
2. Controller must be installed by qualified person.
3. Controller cannot work at temperatures higher than 40°C.
4. Controller should be protected against water flooding and steam condensation.
5. Controller should be installed and used according to handling rules with electric equipment.
6. Fuse burning as a result of wrong pump connection is not considered as a warranty matter.
7. It is recommended to check controller’s settings before lightning up of the boiler.
8. Controller is equipped with two 1,25 A fuses