1.7. Overheating valve connection
8
9
2. Burner dimensions and technical data
Technical data
Burner power
Measured
in
16kW
24kW 49 kW
Efficiency
%
~ 91
~ 91 ~~91
Burner power range
kW
3,2 - 16
4,8- 24 9,8-49
CO emission
ppm
42
45 ~75
Burner weight
kg
14
15 17
Feeder length
m
2
2 2
Fuel
pellets
pellets pellets
Fuel diameter
mm
6 -8
6 -8 6-8
Voltage
V
230
230 230
Power consumption
W
30
35 45
Protection level
IP40
IP40 IP 40
ORLIGNO 100 is equipped with copper cooling coil mounted in boiler body, protecting boiler from
overheating. To one of cooling coil tappings on right side of the boiler one should connect safety valve.
When temperature increases above 95
º
C safety valve opens and lets in cold water through cooling
coil. Water from mains at 10
º
C temperature cools down boiler, water from boiler is removed to drain.