12.1.3 Settings
Function
Description
Comfortable temp.
Desired temperature in the room during the heating.
Programme
Programs:
a. time - according to preset intervals
b. constant - regardless of the time intervals comfortable
temperature is maintained
c. disabled - off the heat
d. economic - in the rooms temperature is maintained the
economic
Economic temp.
Desired temperature in the room outside the period of
heating.
12.1.4 Time program
Used to configure the time program steering central heating..
Description of the adjustment time program refer to chapter 10.4.
12.1.5 Service
WARNING!
Access the service is intended only for qualified technical personnel. The changes may
cause malfunction of the system.
Function
Description
Comf. MAX pump temp.
Maximum outdoor temperature at which the circulating pump
can work in a comfortable range.
Econ. MAX pump temp.
Maximum outdoor temperature at which the circulating pump
can work in a economic range.
MIN Tch pump
Minimum temperature calculated for central heating at which the
circulating pump can be operated.
Source
Specifies the source of energy for central heating circuit.
Temperature MAX
Maximum temperature for central heating.
Mixer time
Time of full opening of the mixer.
Hot water priority
Priority for hot water of the heating circuit.
During heating hot water the central heating pump is not working.
Pump test
Starts the pump regardless of other conditions.
Mixer test
Starts the mixer motor independently of the other conditions.
Circ. name
Gives name for the central heating circuit.
36
37
Содержание ORLIGNO 100 16kW
Страница 1: ...ORLIGNO 100 16 24 49 kW MANUAL AND SERVICE MANUAL ISO 9001 ISO 14001 ...
Страница 7: ...1 5 Boiler dimensions 16kW 7 24kW 49kW ...
Страница 10: ...16kW 24kW 10 ...
Страница 17: ...17 Pic 5 Burner assembly Pic 6 Feeder assembly 4 1 5 3 2 6 7 10 9 9 8 11 12 ...
Страница 34: ...12 Main menu 41 44 46 47 48 50 52 58 59 34 ...
Страница 55: ...55 ...