SOLAR WATER HEATERS
Drawing 1
For the system’s optimum operation using natural circulation,
the maximum and minimum distances and angles for the
pipes must be respected. The maximum distance between
the collector outlet and the water storage tank inlet must not
exceed 3m. The angle of the pipe joining these 2 points must
not be less than 8°.
SYSTEM INSTALLATION ON A TILED ROOF WITH THE WATER STORAGE
TANK UNDER THE ROOF (Natural circulation operation)
ELECTRICAL COMPONENTS (Heating Element - Thermostat)
THERMOSTAT AUTOMATIC
AUXILIARY THERMOELECTRIC
FUSE
This is tripped when the water storage
tank’s internal temperature exceeds
95°C and shuts down the thermostat, to
protect the appliance form overheating.
RESETTING THE
THERMOELECTRIC FUSE
Rotate the temperature regulator until
the button of the thermoelectric fuse
appears and press it. Once the fuse
has been reset to its normal operating
position (pressed in), the thermostat
can operate again.
Thermostat
Temperature
Regulator
(40-80°C)
HEATING
ELEMENT
Earthing
L = Phase
N = Neutral
8°
MAX. DISTANCE 3m
MIN. ANGLE 8°