Orkli SPT 1-160 Скачать руководство пользователя страница 23

23

The company preserves the right to change all specifications of the products and their accessories without prior notice

SOLAR WATER HEATERS

HYDRAULIC CONNECTION

CONNECTING THE SYSTEM WITH THE COLD AND HOT WATER MAINS

The “COLD WATER INLET” and “HOT WATER OUTLET” sockets colored blue and red respectively are located on 

the side of the water storage tank.

ATTENTION! 

The connections to the hot and cold water pipes should be made with union nuts and not by soldering.

1. 

Onto the “COLD WATER INLET” safety valve (10 bar) is screwed first, followed by a mini ball valve. The cold 

water pipe is then connected to the ball valve with an insulated plastic pipe (Drw 1).

NOTE: 

The safety valve should have a drain pipe connected to its outlet. This pipe should run to ground level 

where hot water discharge is safe and clear of any paved areas. Do not seal or block the ends of this drain pipe 

or the valve outlet. Drinking water may be drained from this pipe during high irradiation situations.

2. 

The “HOT WATER OUTLET” is then connected to the hot water pipe of the consumer network through an 

insulated plastic pipe ( Plastic pipes are recommended to minimize electro-corrosion).

3. 

Filling the water storage tank WITH WATER: With the ball valve and a hot water tap open, the water storage tank 

is allowed to be filled with cold water. When water starts to run out of the tap, the water storage tank is full and 

the hot water tap can be closed.

4. 

In order to avoid overheating at the consumption points, a thermostatic mixing valve must be installed at the 

outlet of the solar water heater.

Drw 1

Drw 3

Drw 2

PERCENTAGE %

5

10

15

20

25

30

40

45

50

55

TEMPERATURE °C

-2

-4

-6

-8

-11

-15

-19

-24

-30

-37

CLOSED LOOP FILLING

ATTENTION!

 

 

B

efore starting to fill the closed loop with anti freeze liquid, the water storage tank has to be 

completely filled with water.

1. 

Connect the water mains to the specially designed filling fitting on the right of the water storage tank (Drw 2) & fill 

approx. half of the closed loop. Add water to the anti freeze liquid, putting double quantity of water in an empty 

pot. Disconnect the water mains from the filling fitting & empty the anti freeze liquid solution that we have  

 

prepared with the help of a funnel. Connect again the water mains and fill the closed loop completely. 

ATTENTION!

 The last filling phase should be realized with controlled flow, given that at the closed loop overflow 

(3.5 bar safety valve connection point) the fluid may reach high temperatures, which may mean risk of skin burns.

2. 

When

  the  closed  loop  is  completely  filled,  securely  tighten  the  3.5  bar  safety  valve  in  position  (Drw  3)  and 

disconnect the mains from the special filling fitting.

3. 

Uncover the collectors and clean the glass removing all the information stickers.

4. 

Check for leaks and make sure that all pipe joints to the collectors and the water storage tank, as well as the 

cold & hot water pipes towards the system are properly insulated, in order to avoid thermal loss and protect them 

against frost.

5. 

After the completion of the installation, no hot water should be consumed for a couple of hours (depending on the 

weather conditions and the solar irradiation), in order for the closed loop to be set in operation.

ANTI FREEZE LIQUID

 is an advanced, propylene glycol based special product, designed and formulated in order 

to ensure effective heat transfer properties at high or low temperatures. It is non-toxic and provides protection up 

to -37°C (solution 55% v/v with water). It is especially designed to provide excellent anticorrosion properties. In 

aquacius solutions anti freeze liquid offers protection according to the extent of dilution as per in the table below:

Содержание SPT 1-160

Страница 1: ...TECHNICAL MANUAL Solar water heaters Installation maintenance use instructions...

Страница 2: ......

Страница 3: ...AYOUT 11 ORKLI 320lt 4m2 LAYOUT 12 GENERAL INSTALLATION RULES 13 INSTALLATION POSITION 14 GENERAL PREVENTION MEASURES 15 LIGHTNING PROTECTION 15 SUPPORT BASE PARTS 16 SUPPORT BASE ASSEMBLY ON A FLAT S...

Страница 4: ...water heater maximum use of hot water should be made during daytime so that the system can continuously produce hot water during the daylight hours maintaining thus its maximum efficiency SOLAR WATER...

Страница 5: ...rm their quality They are highly aesthetic systems which can be simply and quickly installed to blend with the traditional or modern architecture of a building and to provide free hot water almost the...

Страница 6: ...ears in the following table MODEL ORKLI SPT 1 160 ORKLI SPT 2 320 DESCRIPTION 160lt tank 2 0m2 collector 320lt tank 2 x 2 0m2 collectors SOLAR WATER HEATERS FITTINGS ACCESSORIES 1 COLLECTOR 2 COLLECTO...

Страница 7: ...cerrado S N XXXXXX Fecha XX XXXX IP 23 Capacity Capacidad XXX lt Capacity Closed Loop Capacidad del circuito cerrado XXX lt Nom Pressure Pression nominal XXX bar Dimensions LxWxH Dimensiones LxAxA mm...

Страница 8: ...nnection cable 11 Cold water inlet 1 2 BSP male threaded pipe end for water stratification and 10 bar safety valve for releasing pressure 12 Hot water outlet 1 2 BSP male threaded pipe end 13 Jacket i...

Страница 9: ...manifolds fitting thus avoiding pressure drop in the collectors tube pitch 93mm EN 1652 4 Sun Selective complete area absorber made of selective aluminium sheet with a special titan coating formed in...

Страница 10: ...f supporting base system made of 2 5mm thick galvanised steel for installation on flat or inclined surfaces SUPPORT BASE YEARLY ENERGY OUTPUT kWh m2 ATHENS GREECE 614 DAVOS SWITZERLAND 795 W RZBURG GE...

Страница 11: ...2 4 1 3 6 5 8 7 1 2 6 5 4 8 7 ITEM Nr PART DIM SIONS QTY 1 Beam L Laminate section 60 x 2 5mm 2060 x 60mm 2 2 Beam L Laminate section 60 x 2 5mm 2250 x 60mm 2 3 Beam L Laminate section 60 x 2 5mm 119...

Страница 12: ...5 8 7 1 2 6 5 4 8 7 ITEM Nr PART DIM SIONS QTY 1 Beam L Laminate section 60 x 2 5mm 2060 x 60mm 2 2 Beam L Laminate section 60 x 2 5mm 2250 x 60mm 2 3 Beam L Laminate section 60 x 2 5mm 1190 x 60mm 2...

Страница 13: ...formance should be corrected by increasing the collector surface following a study and evaluation of the specific conditions that apply As the sun ray s angle of attack varies with time but also depen...

Страница 14: ...for the solar water heater installation INSTALLATION POSITION The installation is only allowed on roofs and flat surfaces of adequate bearing capacity Before you proceed with the installation make su...

Страница 15: ...ause accidents Requirements related to the personnel y y The installation of our Solar Thermal systems can only be undertaken by authorized specialized companies and trained personnel y y Works in ele...

Страница 16: ...16 The company preserves the right to change all specifications of the products and their accessories without prior notice For 2 0m2 collectors SUPPORT BASE PARTS For 4 0m2 collector 2 x 2 0m2...

Страница 17: ...parts of the frame and tighten all screws Repeat steps 1 2 3 for the other pairs of parts SUPPORT BASE ASSEMBLY ON A FLAT SURFACE 1 Screw parts 1 to part 2 using the M8 screws and nuts included in th...

Страница 18: ...tank s side where the heating element is located and to the socket marked collector intake 12 Join the other end to the top left socket of the collector using the 22x DN16 INOX corner fitting having f...

Страница 19: ...insulation tube Tighten all unions in the system as well as all the screws on the base Do the hydraulic connection fill the closed loop and do the electrical connection as described in the relevant s...

Страница 20: ...ctor supporting part 5 to the bottom part of the frame and tighten the screws 4 Screw the collector supporting part 5 to the top part of the frame without tightening the screws 5 Bend the straight par...

Страница 21: ...ace the small flexible tube on the special connection DN16 INOX at the water storage tank s side where the heating element is located and to the socket marked collector intake 12 Join the other end to...

Страница 22: ...ing firstly passed the tube through the insulation tube Tighten all unions in the system as well as all the screws on the base Do the hydraulic connection fill the closed loop and do the electrical co...

Страница 23: ...the closed loop with anti freeze liquid the water storage tank has to be completely filled with water 1 Connect the water mains to the specially designed filling fitting on the right of the water sto...

Страница 24: ...to the electrical board using a bipolar disconnection switch with a minimum distance between contacts of at least 3mm The circuit breaker s rating must be suitable for the heating element in use Cauti...

Страница 25: ...TILED ROOF WITH THE WATER STORAGE TANK UNDER THE ROOF Natural circulation operation ELECTRICAL COMPONENTS Heating Element Thermostat THERMOSTAT AUTOMATIC AUXILIARY THERMOELECTRIC FUSE This is tripped...

Страница 26: ...lity of slow leakage 8 Make sure the hot water supply is not mixing with a cold water supply 9 Make sure the connecting pipes are not kinked 10 Check the level of the antifreeze liquid and top up if n...

Страница 27: ...and a hot water tap until the water storage tank fills up 10 Check for water leaks 11 Reconnect the electrical components at their designated positions 12 Check that the thermostat is securely clipped...

Страница 28: ...recommended that the glass is washed at an hour of low sunlight to avoid damages due to expansion contraction due to temperature changes y y If the fittings are worn screws pugs piping etc these shou...

Страница 29: ...protection on the thermal insulation Is the piping properly insulated Has the installment on the roof been done according to the local regulations HYDRAULIC CONNECTIONS Are there any leaks in the clo...

Страница 30: ...30 The company preserves the right to change all specifications of the products and their accessories without prior notice NOTES...

Страница 31: ......

Страница 32: ...V1 03 14 www orkli es...

Отзывы: