1. 

Remove the screws from the protection flap which covers the electrical components (Drw 1).

2. 

A 3x4mm² section electrical cable (for a 4kW heating element) is required to connect the heating element to the 

mains (Drw 2).

3. 

Pass the end of the cable through the gland and towards the electrical components.

4. 

Connect the black wire (phase) to the connector L and the blue wire (neutral) to the connector N on the 

thermostat. Connect the yellow wire (earthing) to the small M4 screw on the heating element marked with the 

ground symbol (Drw 3).

5. 

The thermostat has been connected to the heating element at the factory. Adjust the thermostat to 60°C. 

ATTENTION!

 The thermostat should be well fitted at the heating element (Drw 1)

6. 

Close the cover of the electrical components (Drw 4)

7. 

Switch off the central mains switch.

8. 

Connect the other end of the cable to the electrical board using a bipolar disconnection switch with a minimum 

distance between contacts of at least 3mm. The circuit breaker’s rating must be suitable for the heating element 

in use.

Caution!

 A safety relay against electrical shock is absolutely necessary.

NOTE:

 The daily hot water (40

°C

) load which can be met by the system without any contribution from solar energy 

(that is, only through 24h 2kW heating element operation), according to 5.10 of EN 12976-2:2000, is this of maximum 

1000lt. 

Drw 3

Drw 4

Drw 1

Drw 2

ELECTRICAL CONNECTION (OPTIONAL)

DESCRIPTION OF ELECTRICAL COMPONENTS (heating element - thermostat - accessories)

ELECTRICAL DIAGRAM - General rules

The electrical installation of the solar water heater should be carried out by a qualified electrician and in 

accordance 

with the national regulations in force and the rules and conditions that apply to the building where the installation is 

taking place.

The heating element must not be switched on when there is no water in the water storage tank.

In such case the heating element warranty does not apply.

NOTE:

 The heating element’s rating depends on local regulations of the country of destination.

Содержание SPT 1-160

Страница 1: ...TECHNICAL MANUAL Solar water heaters Installation maintenance use instructions...

Страница 2: ......

Страница 3: ...AYOUT 11 ORKLI 320lt 4m2 LAYOUT 12 GENERAL INSTALLATION RULES 13 INSTALLATION POSITION 14 GENERAL PREVENTION MEASURES 15 LIGHTNING PROTECTION 15 SUPPORT BASE PARTS 16 SUPPORT BASE ASSEMBLY ON A FLAT S...

Страница 4: ...water heater maximum use of hot water should be made during daytime so that the system can continuously produce hot water during the daylight hours maintaining thus its maximum efficiency SOLAR WATER...

Страница 5: ...rm their quality They are highly aesthetic systems which can be simply and quickly installed to blend with the traditional or modern architecture of a building and to provide free hot water almost the...

Страница 6: ...ears in the following table MODEL ORKLI SPT 1 160 ORKLI SPT 2 320 DESCRIPTION 160lt tank 2 0m2 collector 320lt tank 2 x 2 0m2 collectors SOLAR WATER HEATERS FITTINGS ACCESSORIES 1 COLLECTOR 2 COLLECTO...

Страница 7: ...cerrado S N XXXXXX Fecha XX XXXX IP 23 Capacity Capacidad XXX lt Capacity Closed Loop Capacidad del circuito cerrado XXX lt Nom Pressure Pression nominal XXX bar Dimensions LxWxH Dimensiones LxAxA mm...

Страница 8: ...nnection cable 11 Cold water inlet 1 2 BSP male threaded pipe end for water stratification and 10 bar safety valve for releasing pressure 12 Hot water outlet 1 2 BSP male threaded pipe end 13 Jacket i...

Страница 9: ...manifolds fitting thus avoiding pressure drop in the collectors tube pitch 93mm EN 1652 4 Sun Selective complete area absorber made of selective aluminium sheet with a special titan coating formed in...

Страница 10: ...f supporting base system made of 2 5mm thick galvanised steel for installation on flat or inclined surfaces SUPPORT BASE YEARLY ENERGY OUTPUT kWh m2 ATHENS GREECE 614 DAVOS SWITZERLAND 795 W RZBURG GE...

Страница 11: ...2 4 1 3 6 5 8 7 1 2 6 5 4 8 7 ITEM Nr PART DIM SIONS QTY 1 Beam L Laminate section 60 x 2 5mm 2060 x 60mm 2 2 Beam L Laminate section 60 x 2 5mm 2250 x 60mm 2 3 Beam L Laminate section 60 x 2 5mm 119...

Страница 12: ...5 8 7 1 2 6 5 4 8 7 ITEM Nr PART DIM SIONS QTY 1 Beam L Laminate section 60 x 2 5mm 2060 x 60mm 2 2 Beam L Laminate section 60 x 2 5mm 2250 x 60mm 2 3 Beam L Laminate section 60 x 2 5mm 1190 x 60mm 2...

Страница 13: ...formance should be corrected by increasing the collector surface following a study and evaluation of the specific conditions that apply As the sun ray s angle of attack varies with time but also depen...

Страница 14: ...for the solar water heater installation INSTALLATION POSITION The installation is only allowed on roofs and flat surfaces of adequate bearing capacity Before you proceed with the installation make su...

Страница 15: ...ause accidents Requirements related to the personnel y y The installation of our Solar Thermal systems can only be undertaken by authorized specialized companies and trained personnel y y Works in ele...

Страница 16: ...16 The company preserves the right to change all specifications of the products and their accessories without prior notice For 2 0m2 collectors SUPPORT BASE PARTS For 4 0m2 collector 2 x 2 0m2...

Страница 17: ...parts of the frame and tighten all screws Repeat steps 1 2 3 for the other pairs of parts SUPPORT BASE ASSEMBLY ON A FLAT SURFACE 1 Screw parts 1 to part 2 using the M8 screws and nuts included in th...

Страница 18: ...tank s side where the heating element is located and to the socket marked collector intake 12 Join the other end to the top left socket of the collector using the 22x DN16 INOX corner fitting having f...

Страница 19: ...insulation tube Tighten all unions in the system as well as all the screws on the base Do the hydraulic connection fill the closed loop and do the electrical connection as described in the relevant s...

Страница 20: ...ctor supporting part 5 to the bottom part of the frame and tighten the screws 4 Screw the collector supporting part 5 to the top part of the frame without tightening the screws 5 Bend the straight par...

Страница 21: ...ace the small flexible tube on the special connection DN16 INOX at the water storage tank s side where the heating element is located and to the socket marked collector intake 12 Join the other end to...

Страница 22: ...ing firstly passed the tube through the insulation tube Tighten all unions in the system as well as all the screws on the base Do the hydraulic connection fill the closed loop and do the electrical co...

Страница 23: ...the closed loop with anti freeze liquid the water storage tank has to be completely filled with water 1 Connect the water mains to the specially designed filling fitting on the right of the water sto...

Страница 24: ...to the electrical board using a bipolar disconnection switch with a minimum distance between contacts of at least 3mm The circuit breaker s rating must be suitable for the heating element in use Cauti...

Страница 25: ...TILED ROOF WITH THE WATER STORAGE TANK UNDER THE ROOF Natural circulation operation ELECTRICAL COMPONENTS Heating Element Thermostat THERMOSTAT AUTOMATIC AUXILIARY THERMOELECTRIC FUSE This is tripped...

Страница 26: ...lity of slow leakage 8 Make sure the hot water supply is not mixing with a cold water supply 9 Make sure the connecting pipes are not kinked 10 Check the level of the antifreeze liquid and top up if n...

Страница 27: ...and a hot water tap until the water storage tank fills up 10 Check for water leaks 11 Reconnect the electrical components at their designated positions 12 Check that the thermostat is securely clipped...

Страница 28: ...recommended that the glass is washed at an hour of low sunlight to avoid damages due to expansion contraction due to temperature changes y y If the fittings are worn screws pugs piping etc these shou...

Страница 29: ...protection on the thermal insulation Is the piping properly insulated Has the installment on the roof been done according to the local regulations HYDRAULIC CONNECTIONS Are there any leaks in the clo...

Страница 30: ...30 The company preserves the right to change all specifications of the products and their accessories without prior notice NOTES...

Страница 31: ......

Страница 32: ...V1 03 14 www orkli es...

Отзывы: