Installation and use manual for OT-U250PP & OT-U500PP 

 

Example 

10.

1 Example of connection of inputs with outputs of a standard alarm system 

2 Example of connection of inputs to an alarm with relay outputs 

3 Example of connection of inputs with outputs of an alarm with open collector outputs 

4 Example of connection of outputs to drive LEDS and / or relays 

5 Example of connection of outputs with inputs of an alarm normally opened 

6 Example of connection of outputs with balanced inputs of an antitheft 

7 Example of connection of outputs with anti-robbery connection. 

 

 

Example of connection of inputs with outputs of a standard alarm system 

10.1.

 

In the diagram above the control panel, as example, provides to Orion Fogging system power supply 

between 11 and 14V DC 250 mA max. 

The ON/OFF output of this alarm is an Open Collector NPN opened when the system is off and it is stably 

closed to negative as long as the system turned on. 

The alarm output of the alarm is normally open and becomes positive during the alarm time. 

 

 

Example of connection of inputs to an alarm with relay outputs 

10.2.

 

ON/OFF output of this alarm central is an open relay when the system is off and it is stably closed to 

positive as long as the system is turn on. 

 

 

 

Содержание OT-U250PP

Страница 1: ...Installation and use manual for OT U250PP OT U500PP...

Страница 2: ...system 9 10 1 Example of connection of inputs to an alarm with relay outputs 9 10 2 Example of connection of inputs with outputs of an alarm with open collector outputs 10 10 3 Example of connection...

Страница 3: ...on glycol water and alcohol Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to the substances listed above At the date of printing of th...

Страница 4: ...maximum shown in the shooting table avoid overshooting even if the produced fog is dry and generally doesn t leave residue A shot that goes far beyond the recommended seconds can create a residue prob...

Страница 5: ...n a flat surface The optional bracket mainly recommended for ceiling installation can also simplify standard installation by allowing to use back holes for the passage of cables Remember to use the fi...

Страница 6: ...h features before proceeding with the connection The max current to be considered for the system is 4A The connection to the 230V electricity grid must be performed by a qualified technician Connect t...

Страница 7: ...older battery not included Description of input and output connections 9 INPUTS 9 1 12V Power input 9 1 1 In these inputs is necessary to provide a stable supply between 11V and 14V DC from the alarm...

Страница 8: ...s empty This output NPN open collector closes towards negative when the fogging machine emitted fog for at least 100 or when the bag is empty The signal is activated by a sensor that detects the absen...

Страница 9: ...connection of outputs with anti robbery connection Example of connection of inputs with outputs of a standard alarm system 10 1 In the diagram above the control panel as example provides to Orion Fogg...

Страница 10: ...plest action to take is to use 2 relays to create a connection similar to the one shown in the previous diagram Example of connection of outputs to drive LEDS and or relays 10 4 In case of an empty ba...

Страница 11: ...power supply The outputs are normally opened and connected with input zones of the alarm control panel normally opened Example of connection of outputs with balanced inputs of an antitheft 10 6 In thi...

Страница 12: ...of front LEDS 11 LED BLUE When ON it means the machine is armed and if hot it s ready to shoot Flashing means something is wrong LED RED It is ON when the bag is empty LED GREEN Flashing means the he...

Страница 13: ...ht in the target area the shooting time can be increased or decreased accordingly by referring to the following formula HxLxP x D x V x I HxLxP Height x Width x Depth of the area to protect D Density...

Страница 14: ...n Higher levels of fog over suggested limits may fill the room and leave a residue Any residue usually goes away by itself within 24 48 hours otherwise being soluble in water it is enough to use a wet...

Страница 15: ...was easier to go near the machine and obstruct the nozzle After 15 minutes the compressor will stop automatically If the system is disarmed and armed again the cycle will start again for 15 minutes Af...

Страница 16: ...ew seconds when the pump for nozzle tamper control is turned on as the nozzle temperature rises rapidly reaching temperatures that may cause serious burns The air coming out of the nozzle exceeds 200...

Страница 17: ...r will monitor the nozzle After this time it will deactivate automatically if the fogging system is disarmed the compressor will go on with it reaches 15 minutes If the machine is disarmed and then ar...

Страница 18: ...tial difference or a fault In large size plants or with more than on fogging system connected with the same central in rare situations it may occur that there are potential differences between the equ...

Страница 19: ...f the machine Not included in the warranty moving parts and or damages depending on the incorrect use unless it is found a manufacturing defect in origin Liquid and bags are not covered by warranty BY...

Отзывы: