-66-
-67-
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
10
0
x
01
0
x
04
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
) , Write(Set) –
0
x
02
(
2
)
*Control : Power Off –
0
x
00
(
0
) , Power On –
0
x
01
(
1
)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
10
0
x
01
0
x
04
Variable
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get)Response –
0
x
00
(
0
), Write(Set)Response –
0
x
02
(
2
)
*Control : Power Off –
0
x
00
(
0
) , Power On –
0
x
01
(
1
)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
3
.
3
. Input Source
-
This is the command for changing the input source.
-
This command is available while power is on.
-
CMD :
0
xD
1
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Input Source
Value
0
x
02
0
xD
1
0
x
01
0
x
04
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
), Write(Set) –
0
x
02
(
2
)
* Input Source :
0
x
11
(HDMI
1
A),
0
x
12
(HDMI
1
B),
0
x
13
(HDMI
1
C),
0
x
14
(HDMI
1
D),
0
x
15
(HDMI
2
A),
0
x
16
(HDMI
2
B),
0
x
17
(HDMI
2
C),
0
x
18
(HDMI
2
D),
0
x
31
(UHD
1
),
0
x
32
(UHD
2
)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
xD
1
0
x
01
0
x
04
Variable
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get)Response –
0
x
00
(
0
), Write(Set)Response –
0
x
02
(
2
)
* Input Source :
0
x
11
(HDMI
1
A),
0
x
12
(HDMI
1
B),
0
x
13
(HDMI
1
C),
0
x
14
(HDMI
1
D),
0
x
15
(HDMI
2
A),
0
x
16
(HDMI
2
B),
0
x
17
(HDMI
2
C),
0
x
18
(HDMI
2
D),
0
x
31
(UHD
1
),
0
x
32
(UHD
2
)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
3
.
4
. Information
-
It is the command for displaying the information of LCD set status.
-
It is available only during Power On (Operative) status.
-
CMD :
0
x
1
A
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Value
0
x
02
0
x
1
A
0
x
01
0
x
03
Variable
Variable
Variable
0
x
03
*Group/Multi ID Range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Write(Set) –
0
x
02
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Value
0
x
02
0
x
1
A
0
x
01
0
x
03
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Write(Set)Response –
0
x
02
(
2
)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
4
. Picture Control Command
4
.
1
. Brightness Control
-
This is the command to adjust the overall image and background brightness.
-
It is available only on Power On (Operative) status.
-
The adjusted value cannot be applied for Stand-By or No input status. So, it can be applied when LCD is in operating condition with the input
signal.
-
CMD :
0
x
20
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
20
0
x
01
0
x
04
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
) , Write(Set) –
0
x
02
(
2
)
*Control :
0
x
00
(
0
) ~
0
x
64
(
100
)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
20
0
x
01
0
x
04
Variable
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get)Response –
0
x
00
(
0
), Write(Set)Response –
0
x
02
(
2
)
*Control :
0
x
00
(
0
)~
0
x
64
(
100
)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
4
.
2
. Contrast Control
-
This is the command to adjust the image brightness in relationship to the background.
-
It is available only on Power On (Operative) status.
-
The adjusted value cannot be applied for Stand-By or No input status. So, it can be applied when LCD is in operating condition with the input
signal.
-
CMD :
0
x
21
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
21
0
x
01
0
x
04
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
) , Write(Set) –
0
x
02
(
2
)
* Control :
0
x
00
(
0
) ~
0
x
64
(
100
)
Содержание OLS-8410NL