TRGPS-9084TG-M12X-BP2-MV User
Manual
ORing Industrial Networking Corp
192
be applied.
PD Class
Each power device is classified according to the class
that defines the maximum power consumed by the PD.
This setting includes five classes:
Class 0
: Max. power 15.4 W
Class 1
: Max. power 4.0 W
Class 2
: Max. power 7.0 W
Class 3
: Max. power 15.4 W
Class 4
: Max. power 30.0 W
Power Requested
Shows the amount of power requested by the power
device
Power Allocated
Shows the amount of power the switch has allocated for
the power device
Power Used
Shows how much power the power device currently is
using
Current Used
Shows how much current the PD currently is using
Priority
Shows the port's priority configured by the user
Port Status
Shows the port's status. The status can be one of the
following values:
PoE not available
: no PoE chip found
PoE turned OFF
: PoE is disabled by user.
PoE turned OFF
: power budget exceeded. The total
requested or used power by the power devices exceeds
the maximum power the power supply can deliver, and
port(s) with the lowest priority will be powered down.
No PD detected
: no power devices detected on the port
PoE turned OFF
: power devices overload. The power
devices have requested or used more power than the
port can deliver, and the port is powered down.
PoE turned OFF
: the power device is turned off.
Invalid PD
: the power device is detected, but is not
working correctly.