SNMP engine with which this user can communicate. In other words,
if user engine ID is the same as system engine ID, then it is local
user; otherwise it's remote user.
User Name
A string identifying the user name that this entry should belong to.
The allowed string length is 1 to 32, and only ASCII characters from
33 to 126 are allowed.
Security Level
Indicates the security model that this entry should belong to. Possible
security models include:
NoAuth, NoPriv
: no authentication and none privacy
Auth, NoPriv
: Authentication and no privacy
Auth, Priv
: Authentication and privacy
The value of security level cannot be modified if the entry already
exists, which means the value must be set correctly at the time of
entry creation.
Authentication
Protocol
Indicates the authentication protocol that this entry should belong to.
Possible authentication protocols include:
None
: no authentication protocol
MD5
: an optional flag to indicate that this user is using MD5
authentication protocol
SHA
: an optional flag to indicate that this user is using SHA
authentication protocol
The value of security level cannot be modified if the entry already
exists, which means the value must be set correctly at the time of
entry creation.
Authentication
Password
A string identifying the authentication pass phrase. For MD5
authentication protocol, the allowed string length is 8 to 32. For SHA
authentication protocol, the allowed string length is 8 to 40. Only
ASCII characters from 33 to 126 are allowed.
Privacy Protocol
Indicates the privacy protocol that this entry should belong to.
Possible privacy protocols include:
None
: no privacy protocol
DES
: an optional flag to indicate that this user is using DES
authentication protocol
Privacy Password
A string identifying the privacy pass phrase. The allowed string length
is 8 to 32, and only ASCII characters from 33 to 126 are allowed.