background image

  WLAN

模块使用手册

 

 

21                                                                                                ORing Industrial Networking Corp. 

7. Compliance 

FCC Statement 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions:   
(1) this device may not cause harmful interference and (2) this device must accept any 
interference received, including interference that may cause undesired operation. 
 
RF exposure warning: The equipment complies with RF exposure limits set forth for an 
uncontrolled environment. The antenna(s) used for this transmitter must not be co-located or 
operating in conjunction with any other antenna or transmitter. 
 
You are cautioned that changes or modifications not expressly approved by the party 
responsible for compliance could void your authority to operate the equipment. This device 
should be operated with minimum distance 20cm between the device and all persons.   

 

Industry Canada Statement 

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is 
subject to the following two conditions: (1) this device may not cause interference, and (2) this 
device must accept any interference, including interference that may cause undesired 
operation of the device.   
 

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio 

exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil 

ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage 

radioélectrique subi, même si le brouillage est susceptible d'en compromettre le 

fonctionnement.  

 
Industry Canada - Class B This digital apparatus does not exceed the Class B limits for radio 
noise emissions from digital apparatus as set out in the interference-causing equipment 
standard entitled “Digital Apparatus,” ICES-003 of Industry Canada.     
 

Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux 

appareils numériques de Classe B prescrites dans la norme sur le matérial brouilleur: 

“Appareils Numériques,” NMB-003 édictée par l’Industrie.   

 
Operation is subject to the following two conditions: (1) this device may not cause interference, 

Содержание IAR-630-C

Страница 1: ...User Manual Version 1 0 June 2016 IAR 630 C IAR 630 D...

Страница 2: ...P List 4 3 Basic Setting 5 3 1 System Info Setting 5 3 2 WAN 5 3 3 LAN 6 4 Wireless Setting 8 4 1 AP Mode 8 4 2 Wireless Option 10 5 Firewall settings 10 5 1 Firewall 10 5 2 Port Forwards 11 5 2 IP Fo...

Страница 3: ...Input 2 Ethernet LAN 1 10 100Base T X RJ45 LAN 2 10 100Base T X RJ45 WAN LAN 3 10 100 1000Base T X RJ45 3 Console PWR Serial RS232 115200 8 1 None 4 Reset Reset Press reset button 5 seconds then the...

Страница 4: ..._TxD Pin3 UART_RxD Pin4 0V 3 LED Description LED Color Status Description PWR Green ON DC power is active WLAN Green ON WLAN is active Blinking Data is being transmitted SYS Green ON System startup is...

Страница 5: ...ustrial Networking Corp Management Interface 1 Device Default Setting IP Addesss 192168 1 1 255 255 255 0 Username admin Password admin 2 Over View 2 1 System Info This Page will show the System Infor...

Страница 6: ...Corp 4 2 2 LAN Info This Page will show the LAN Information in detail 2 3 Wireless Info This Page will show the wireless Information in detail 2 4 DHCP List This Page will show the wireless DHCP clien...

Страница 7: ...onfigure LAN 3 Ethernet Port from LAN to WAN mode in order to connect to outside network you can set the WAN IP by DHCP or Static IP mode Label Description Obtain an IP address automatically Select th...

Страница 8: ...ust first set the LAN port as WAN mode by Dip Switch W 3 3 LAN Label Description Obtain an IP address automatically Select this option if you would like to obtain an IP address automatically assigned...

Страница 9: ...ic IP assign range Start IP address is the beginning of the dynamic IP assigns range Maximum Number of IPs The dynamic IP assign range High IP address is the end of the dynamic IP assigns range Lease...

Страница 10: ...is mode provides Access Point services for other wireless clients Label Description Device Mode AP Device plays the role of wireless Access Point Client Device plays the role of wireless Client WDS De...

Страница 11: ...x You can configure the device to use up to 4 SSIDs and configure each SSID differently Wireless Disabled Enable Disable Wireless Function Notes You can Enable Disable wireless function by Dip switch...

Страница 12: ...Indication Message Fragmentation Threshold Specifies the maximum size a data packet before splitting and creating another new packet RTS Threshold Determines how large a packet can be before the Acce...

Страница 13: ...the external device access the internal device application by device WAN IP address and TCP UDP Number for example FTP Email LAN IP 192 168 1 1 24 WAN 192 168 0 2 24 IP Camera IP 192 168 1 100 24 Gat...

Страница 14: ...al IP address Set the internal device IP address Internal Port The Application use internal TCP UDP number Notes As shown above Picture the PC from external network can use ftp application which provi...

Страница 15: ...dcast Packet Destnation 25 255 255 0 Label Description Name Set the application Name Internal Port The packets used TCP UDP number Source IP The Packets Source IP address Destination IP The Packets De...

Страница 16: ...d MAC addresses to connect the device The device can set different policy by each SSID Label Description Disabled Disable Mac Filter policy Allow List Only Only the wireless client fitting the entitie...

Страница 17: ...ct the Network 6 System Tools 6 1Time Setting Label Description Timezone Set the timezone when you use NTP Server Synchronize the time System time Show the current system time Click Button the device...

Страница 18: ...Label Description SNMP Agent Port Set SNMP Agent Port System Location Set device location information System Contact Set device contact people System Name Set device name Community Use a community st...

Страница 19: ...Wireless Client is connected to the Device External Server IP Enter the external log server IP address External Server Port Enter the external log server communication port Enable SNMP Trap Enable SN...

Страница 20: ...k the Browse button to specify the firmware image file and selected reset to default box then Click Apply changes start the firmware upgrade After the upgrade finished the device will reboot itself At...

Страница 21: ...he new password for confirmation Label Description Reset to default Click Perform reset button to reset all settings back to the factory default values You can also reset the hardware by pressing the...

Страница 22: ...WLAN ORing Industrial Networking Corp 20 6 4 Logout Click Apply change to logout current configure page...

Страница 23: ...subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device...

Страница 24: ...ncontrolled environment The antenna s used for this transmitter must not be co located or operating in conjunction with any other antenna or transmitter Avertissement d exposition RF L quipement est c...

Отзывы: