It will remain the responsibility of individual technical committees to decide on the 
extent and manner in which, the classification is used in their standards and to define 
“enclosure” as it applies to their equipment. However, it is recommended that for 
a given classification the tests do not differ from those specified in this standard. If 
necessary, complementary requirements may be included in the relevant product 
standard. A guide for the details to be specified in relevant product standards is given 
in annex B.

For a particular type of equipment, a technical committee may specify different re-
quirements provided that at least the same level of safety is ensured.

This standard deals only with enclosures that are in all other respects suitable for their
intended use as specified in the relevant product standard and which from the point of 
view of materials and workmanship ensure that the claimed degrees of protection are 
maintained under the normal conditions of use.

This standard is also applicable to empty enclosures provided that the general test
requirements are met and that the selected degree of protection is suitable for the 
type of equipment to be protected.

Measures to protect both the enclosure and the equipment inside the enclosure 
against external influences or conditions such as
– mechanical impacts
– corrosion
– corrosive solvents (for example, cutting liquids)
– fungus
– vermin
– solar radiation
– icing
– moisture (for example, produced by condensation)
– explosive atmospheres

and the protection against contact with hazardous moving parts external to the enclo-
sure (such as fans), are matters for the relevant product standard to be protected.

Barriers external to the enclosure and not attached to it and obstacles which have 
been provided solely for the safety of personnel are not considered as a part of the 
enclosure and are not dealt with in this standard.

d) Speakers intended for security applications; these products are covered in the 
Standard for Local Burglar Alarm Units and Systems, UL 609; and the Standard for 
Household Burglar-Alarm System Units, UL 1023.
1.3 Speakers intended for use with fire alarm systems are covered by Standard for 
Speakers for Fire Alarm and Signaling Systems, Including Accessories, UL 1480. 
Speakers with integral amplifiers must comply with the requirements in UL 1480 
and the Standard for Amplifiers for Fire Protective Signaling Systems, UL 1711.

1.4 Speakers intended for use with emergency and non-emergency systems and 
having integral amplifiers must comply with this standard in addition to the require-
ments in the Standard for General-Purpose Signaling Devices and Systems, UL 2017.

1.5 Speakers intended for use in air-handling spaces in accordance with Installa-
tion of Air Conditioning and Ventilating Systems, NFPA 90A, shall comply with the 
requirements in this standard and the requirements in the Standard for Fire Test 
for Heat and Visible Smoke Release for Discrete Products and Their Accessories 
Installed in Air-Handling Spaces, UL 2043.

15B. IEC 60529: 

IPX4 Rated

This standard applies to the classification of degrees of protection provided by enclosures 
for electrical equipment with a rated voltage not exceeding 72,5 kV.

Object:

  The object of this standard is to give:

a) Definitions for degrees of protection provided by enclosures of electrical equipment as 
regards: 

1) protection of persons against access to hazardous parts inside the enclosure;

2) protection of the equipment inside the enclosure against ingress of solid foreign objects;

3)  protection  of  the  equipment  inside  the  enclosure  against  harmful  effects  due  to  the 
ingress of water.

b) Designations for these degrees of protection.
c) Requirements for each designation.
d) Tests to be performed to verify that the enclosure meets the requirements of this 
standard.

13

Содержание PROFESSIONAL PS50B

Страница 1: ...Installation Manual PROFESSIONAL COLLECTION Surface Mount Speakers PS50B PS50W PS60B PS60W PS80B PS80W PS50B PS50W PS60B PS60W PS80B PS80W ...

Страница 2: ...nt sound quality longevity and a simple installation process This instruction booklet covers the necessary information for a smooth installation including thetoolsyouwillneed step by stepinstructionsforinstallation troubleshooting tips for any errors that may occur and all warranty information If for any reason you experience problems or if you have installation questions please call us at 844 674...

Страница 3: ...Pink Noise 40 Watts Frequency Response 10dB 45Hz 20kHz Frequency Response 3dB 65Hz 20kHz Nominal Coverage Angle 100 Horizontal 50 Vertical Sensitivity 1m 92dB Rated Maximum SPL 106dB Impedance 8 ohm nominal Transformer Taps 70V 60W 30W 15W 7 5W 100V 60W 30W 15W Dimensions 7 7 8 W x 8 D x 12 1 4 H 200 W x 203 D x 311 H mm 13 1 4 336 mm H with bracket PS50B PS50W Part SSP50000B SSP50000W Woofer 5 1 ...

Страница 4: ...g multiple speakers add the combined wattages of all tap settings to determine the wattage draw on the amplifier The combined total wattage should never exceed the wattage rating of the amplifier WARNING The 8 Ω position cannot be used with a 70 100V connection as it will damage or destroy the transformer Should you be uncomfortable designing or installing a 70 100V system or should you have any q...

Страница 5: ...Origin Acoustics 6975 S Decatur Blvd Suite 140 Las Vegas NV 89118 844 ORIGIN1 674 4461 www originacoustics com A C O U S T I C S O R I G I N 9 42in 239 2mm 9 63in 244 7mm 14 88in 378mm PS80 SCALE 1 5 Origin Acoustics 6975 S Decatur Blvd Suite 140 Las Vegas NV 89118 844 ORIGIN1 674 4461 www originacoustics com A C O U S T I C S O R I G I N 9 42in 239 2mm 9 63in 244 7mm 14 88in 378mm PS80 SCALE 1 5 ...

Страница 6: ...peaker baffle 7a Stripapproximately3 16 5mm oftheinsulationoffeachwire andtoavoidstraystrands twist them at the end 7b Insert the wire into the correct square opening on the phoenix connector Use a small flat head screwdriver to tighten the corresponding screw to secure the wire 9 7c When using multiple speakers you can connect the speakers either in parallel or in the loop through method as shown...

Страница 7: ...ystems in accordance with NFPA 70 exam ples of non fire emergency warning systems include but are not limited to 1 Critical process monitoring nuclear plant oil refinery hazardous chemical pro cessing 2 Distress alert systems help for handicapped for life safety for rape for robbery 3 Crowd control in public places sporting arena theater shopping mall transpor tation center and 4 Non fire emergenc...

Страница 8: ...y for the safety of personnel are not considered as a part of the enclosure and are not dealt with in this standard d Speakers intended for security applications these products are covered in the Standard for Local Burglar Alarm Units and Systems UL 609 and the Standard for Household Burglar Alarm System Units UL 1023 1 3 Speakers intended for use with fire alarm systems are covered by Standard fo...

Страница 9: ...returning the product or if needed we can provide instructions and support for the return process 17 Technical Assistance 14 Origin Acoustics warrants to the original retail purchaser only that this Origin Acoustics product will be free from defects in materials and workmanship provided the speaker was purchased from an Origin Acoustics authorized dealer If the product is determined to be defectiv...

Страница 10: ... 6975 S Decatur Blvd Las Vegas NV 89118 www originacoustics com 844 674 4461 2022 Origin Acoustics All copyrighted trademarked and patented elements mentioned herein are the sole property of Origin Acoustics ...

Отзывы: