Origin Acoustics PROFESSIONAL PS50B Скачать руководство пользователя страница 7

Professional Collection Manual 

Professional Collection Manual 

7d.  Determine  the  proper  wattage  setting  for  each  speaker  in  the  installation  and  set  each 
speaker’s Transformer Tap selector on the front of the speaker accordingly. eg: You can set the 
tap to 70V Wattage or 8 ohm. Then fit the wiring terminal cover in the speaker front panel. 

8. Fit the grille onto the speaker.

14. Pivoting The Speaker

The speaker features a Weather Resistant POM Plastic Bracket with vertical angle adjustments. 
You can rotate the speaker between the two ends of the bracket (see A.), and also connect the 
speaker bracket on the vertical yoke mount (C Bracket) (see B.) at its desired vertical position. 
This allows the sound to be aimed towards the listeners as required. 

10

 

9.42in

239.2mm 

 

9.63in

244.7mm 

 

14.88in

378mm  

PS80

SCALE:1:5

Origin Acoustics

6975 S Decatur Blvd

Suite 140

Las Vegas, NV 89118

844-ORIGIN1 (674-4461)

www.originacoustics.com

A  C  O  U  S  T  I  C  S

O R I G I N

®

 

9.42in

239.2mm 

 

9.63in

244.7mm 

 

14.88in

378mm  

PS80

SCALE:1:5

Origin Acoustics

6975 S Decatur Blvd

Suite 140

Las Vegas, NV 89118

844-ORIGIN1 (674-4461)

www.originacoustics.com

A  C  O  U  S  T  I  C  S

O R I G I N

®

15. Safety Agency Compliance

Origin Acoustics Professional Collection In-Ceiling speakers models PC50, PC60, 
PC80, PCSUB8 meet the following standards:

15A. UL 1480A:

 Standard for Speakers for Commercial and Professional Use

Scope:
1.1 These requirements cover speakers for indoor and/or outdoor use in dry, damp, 
wet, or underwater locations and are intended for one or more of the following:
a) Commercial and professional audio systems providing non-emergency sound 
reinforcement and reproduction in accordance with the National Electrical Code, 
NFPA 70 (this includes equipment for institutional, industrial use);
b) Non-fire emergency voice-warning systems in accordance with NFPA 70; exam-
ples of non-fire emergency-warning systems include, but are not limited to:
1) Critical process monitoring (nuclear plant, oil refinery, hazardous chemical pro-
cessing);
2) Distress alert systems (help for handicapped, for life safety, for rape, for robbery);
3) Crowd control in public places (sporting arena, theater, shopping mall, transpor-
tation center); and
4) Non-fire emergency voice-systems covered by the Life Safety Code, NFPA 101.
c) Underwater speakers in accordance with Article 680 of NFPA 70. An underwater 
speaker is not to be used in a fire alarm system or as an emergency (non-fire) 
voice-warning system.

1.2 These requirements do not cover the following:
a) Speakers intended for use in hazardous locations as defined in the National 
Electrical Code, NFPA 70; this includes speakers tested with the requirements in the 
Standard for Explosion-Proof and Dust-Ignition-Proof Electrical Equipment For Use 
In Hazardous (Classified) Locations, UL 1203;
b) Speakers intended for personal or private consumer use; this includes speakers 
for household/domestic use covered by the requirements in the Standard for Au-
dio-Video Products and Accessories, UL 1492 and the Standard for Audio/Video and 
Musical Instrument Apparatus for Household, Commercial, and Similar General Use, 
UL 6500;
c) Speakers which are intended for commercial or professional audio applications 
and which employ integral active electronics; these products are covered in the 
Standard for Commercial Audio Equipment, UL 813; the Standard for Professional 
Video and Audio Equipment, UL 1419; and the commercial audio amplifier applica-
tions covered in UL 6500; 

11

 

9.42in

239.2mm

 

 

9.63in

244.7mm

 

 

14.88in

378mm  

PS80

SCALE:1:5

Origin Acoustics

6975 S Decatur Blvd

Suite 140

Las Vegas, NV 89118

844-ORIGIN1 (674-4461)

www.originacoustics.com

A  C  O  U  S  T  I  C  S

O R I G I N

®

A.

B.

30

15

60

100

8 Ω

OFF

W

V

15

7.5

30

70

60

NA

IN

OUT

C

M

Y

CM

MY

CY

CMY

K

phoenix_front_a.pdf   1   3/31/22   11:42 AM

Содержание PROFESSIONAL PS50B

Страница 1: ...Installation Manual PROFESSIONAL COLLECTION Surface Mount Speakers PS50B PS50W PS60B PS60W PS80B PS80W PS50B PS50W PS60B PS60W PS80B PS80W ...

Страница 2: ...nt sound quality longevity and a simple installation process This instruction booklet covers the necessary information for a smooth installation including thetoolsyouwillneed step by stepinstructionsforinstallation troubleshooting tips for any errors that may occur and all warranty information If for any reason you experience problems or if you have installation questions please call us at 844 674...

Страница 3: ...Pink Noise 40 Watts Frequency Response 10dB 45Hz 20kHz Frequency Response 3dB 65Hz 20kHz Nominal Coverage Angle 100 Horizontal 50 Vertical Sensitivity 1m 92dB Rated Maximum SPL 106dB Impedance 8 ohm nominal Transformer Taps 70V 60W 30W 15W 7 5W 100V 60W 30W 15W Dimensions 7 7 8 W x 8 D x 12 1 4 H 200 W x 203 D x 311 H mm 13 1 4 336 mm H with bracket PS50B PS50W Part SSP50000B SSP50000W Woofer 5 1 ...

Страница 4: ...g multiple speakers add the combined wattages of all tap settings to determine the wattage draw on the amplifier The combined total wattage should never exceed the wattage rating of the amplifier WARNING The 8 Ω position cannot be used with a 70 100V connection as it will damage or destroy the transformer Should you be uncomfortable designing or installing a 70 100V system or should you have any q...

Страница 5: ...Origin Acoustics 6975 S Decatur Blvd Suite 140 Las Vegas NV 89118 844 ORIGIN1 674 4461 www originacoustics com A C O U S T I C S O R I G I N 9 42in 239 2mm 9 63in 244 7mm 14 88in 378mm PS80 SCALE 1 5 Origin Acoustics 6975 S Decatur Blvd Suite 140 Las Vegas NV 89118 844 ORIGIN1 674 4461 www originacoustics com A C O U S T I C S O R I G I N 9 42in 239 2mm 9 63in 244 7mm 14 88in 378mm PS80 SCALE 1 5 ...

Страница 6: ...peaker baffle 7a Stripapproximately3 16 5mm oftheinsulationoffeachwire andtoavoidstraystrands twist them at the end 7b Insert the wire into the correct square opening on the phoenix connector Use a small flat head screwdriver to tighten the corresponding screw to secure the wire 9 7c When using multiple speakers you can connect the speakers either in parallel or in the loop through method as shown...

Страница 7: ...ystems in accordance with NFPA 70 exam ples of non fire emergency warning systems include but are not limited to 1 Critical process monitoring nuclear plant oil refinery hazardous chemical pro cessing 2 Distress alert systems help for handicapped for life safety for rape for robbery 3 Crowd control in public places sporting arena theater shopping mall transpor tation center and 4 Non fire emergenc...

Страница 8: ...y for the safety of personnel are not considered as a part of the enclosure and are not dealt with in this standard d Speakers intended for security applications these products are covered in the Standard for Local Burglar Alarm Units and Systems UL 609 and the Standard for Household Burglar Alarm System Units UL 1023 1 3 Speakers intended for use with fire alarm systems are covered by Standard fo...

Страница 9: ...returning the product or if needed we can provide instructions and support for the return process 17 Technical Assistance 14 Origin Acoustics warrants to the original retail purchaser only that this Origin Acoustics product will be free from defects in materials and workmanship provided the speaker was purchased from an Origin Acoustics authorized dealer If the product is determined to be defectiv...

Страница 10: ... 6975 S Decatur Blvd Las Vegas NV 89118 www originacoustics com 844 674 4461 2022 Origin Acoustics All copyrighted trademarked and patented elements mentioned herein are the sole property of Origin Acoustics ...

Отзывы: