7d. Determine the proper wattage setting for each speaker in the installation and set each
speaker’s Transformer Tap selector on the front of the speaker accordingly. eg: You can set the
tap to 70V Wattage or 8 ohm. Then fit the wiring terminal cover in the speaker front panel.
8. Fit the grille onto the speaker.
14. Pivoting The Speaker
The speaker features a Weather Resistant POM Plastic Bracket with vertical angle adjustments.
You can rotate the speaker between the two ends of the bracket (see A.), and also connect the
speaker bracket on the vertical yoke mount (C Bracket) (see B.) at its desired vertical position.
This allows the sound to be aimed towards the listeners as required.
10
9.42in
239.2mm
9.63in
244.7mm
14.88in
378mm
PS80
SCALE:1:5
Origin Acoustics
6975 S Decatur Blvd
Suite 140
Las Vegas, NV 89118
844-ORIGIN1 (674-4461)
www.originacoustics.com
A C O U S T I C S
O R I G I N
®
9.42in
239.2mm
9.63in
244.7mm
14.88in
378mm
PS80
SCALE:1:5
Origin Acoustics
6975 S Decatur Blvd
Suite 140
Las Vegas, NV 89118
844-ORIGIN1 (674-4461)
www.originacoustics.com
A C O U S T I C S
O R I G I N
®
15. Safety Agency Compliance
Origin Acoustics Professional Collection In-Ceiling speakers models PC50, PC60,
PC80, PCSUB8 meet the following standards:
15A. UL 1480A:
Standard for Speakers for Commercial and Professional Use
Scope:
1.1 These requirements cover speakers for indoor and/or outdoor use in dry, damp,
wet, or underwater locations and are intended for one or more of the following:
a) Commercial and professional audio systems providing non-emergency sound
reinforcement and reproduction in accordance with the National Electrical Code,
NFPA 70 (this includes equipment for institutional, industrial use);
b) Non-fire emergency voice-warning systems in accordance with NFPA 70; exam-
ples of non-fire emergency-warning systems include, but are not limited to:
1) Critical process monitoring (nuclear plant, oil refinery, hazardous chemical pro-
cessing);
2) Distress alert systems (help for handicapped, for life safety, for rape, for robbery);
3) Crowd control in public places (sporting arena, theater, shopping mall, transpor-
tation center); and
4) Non-fire emergency voice-systems covered by the Life Safety Code, NFPA 101.
c) Underwater speakers in accordance with Article 680 of NFPA 70. An underwater
speaker is not to be used in a fire alarm system or as an emergency (non-fire)
voice-warning system.
1.2 These requirements do not cover the following:
a) Speakers intended for use in hazardous locations as defined in the National
Electrical Code, NFPA 70; this includes speakers tested with the requirements in the
Standard for Explosion-Proof and Dust-Ignition-Proof Electrical Equipment For Use
In Hazardous (Classified) Locations, UL 1203;
b) Speakers intended for personal or private consumer use; this includes speakers
for household/domestic use covered by the requirements in the Standard for Au-
dio-Video Products and Accessories, UL 1492 and the Standard for Audio/Video and
Musical Instrument Apparatus for Household, Commercial, and Similar General Use,
UL 6500;
c) Speakers which are intended for commercial or professional audio applications
and which employ integral active electronics; these products are covered in the
Standard for Commercial Audio Equipment, UL 813; the Standard for Professional
Video and Audio Equipment, UL 1419; and the commercial audio amplifier applica-
tions covered in UL 6500;
11
9.42in
239.2mm
9.63in
244.7mm
14.88in
378mm
PS80
SCALE:1:5
Origin Acoustics
6975 S Decatur Blvd
Suite 140
Las Vegas, NV 89118
844-ORIGIN1 (674-4461)
www.originacoustics.com
A C O U S T I C S
O R I G I N
®
A.
B.
30
15
60
100
8 Ω
OFF
W
V
15
7.5
30
70
60
NA
IN
OUT
C
M
Y
CM
MY
CY
CMY
K