6.2  Panel displays and setting items

: Turn the setting dial

: Press the ESC key

: Press the FUNCTION key

: Press the setting dial

E

E

F

F

E

F

1

E

F

E

E

F

E

E

F

E

E

F

E

E

F

E

E

E

E

1

1

E

F

E

E

F

E

1

E

F

1

 

It cannot be performed while the motor is operated.

 

“ 

” will be displayed.

2

 

It is not displayed while the data is locked.

Speed
reduction ratio

Data setting

FWD input

REV input

The LED is lit while the input

signal is ON, and it is unlit when

the input signal is OFF.

Power ON

Rotation speed monitor 

Input signal monitor

The motor rotation speed is displayed.
The display of the lowest digit is fixed to " 

0

" at the time

of shipment.

[Display at the converted value]

    When the "speed reduction ratio" or "speed increasing
    ratio" is set to the value other than 1.00, the converted
    value is displayed.

[Display of the setting speed]

   

If the setting dial is pressed while the operation switch is

   

set to STAND-BY, the setting speed is displayed.

Rotation speed monitor 

Data setting

The data can be locked so that the set value does not change.

Set on the rotation speed monitor screen

If the ESC key is pressed and hold more than
5 seconds, " 

" blinks on the display.

If the ESC key is pressed and hold more than
5 seconds while the data is locked, " 

"

blinks on the display.

Reset:

Lock the setting data

Lock:

If the ESC key is pressed while the speed is changing by

    turning the setting dial (the display is blinking), the motor
    speed returns to the rotation speed before the change.

Execution

Retrun to the "speed reduction ratio"

Data
initialization

2

Speed
increasing ratio

Data setting

Lowest digit
display fixing

Data setting

Prevention of
operation at
power-on alarm

Data setting

Speed upper
and lower limit

Data setting

Speed
upper limit

Data setting

Speed
lower limit

Data setting

Acceleration/
deceleration
time

Data setting

External
operation
signal input

Input signal
monitor

Note

Do not turn off the power supply while the display is blinking after executing the data setting or 
initialization. Doing so may damage the data.

Содержание US2 Series

Страница 1: ...procedures and safety precautions Please read it thoroughly to ensure safe operation Always keep the manual where it is readily available D loop represents the speed control motor which adopted Orien...

Страница 2: ...lays and setting items 19 6 3 Data locking for the set data 20 6 4 Display after setting the speed reduction ratio 20 Display position of decimal point 20 Display the conveyor transfer speed 20 6 5 So...

Страница 3: ...g a cable is attached Input signal terminal Function switching key Front panel Protective Earth Terminal Operating Connecting Connecting Convenient functions When the front panel is removed Motor cabl...

Страница 4: ...company a Caution symbol may result in injury or property damage Do not use the motor and speed controller beyond their specifications Doing so may result in electric shock injury or damage to equipme...

Страница 5: ...Number Length m of a supplied connection cable 1 1 m 3 3 ft 2 2 m 6 6 ft 3 3 m 9 8 ft Blank Without a supplied connection cable Number Gear ratio A Round shaft type Power supply voltage JA Single phas...

Страница 6: ...0 UA Single phase 200 VAC US2 560JC o SCM560GVH JC US2D60 JC Single phase 220 230 VAC US2 560EC o SCM560GVH EC US2D60 EC 90 W Single phase 100 VAC US2 590JA o SCM590GVR JA 5GVRoB US2D90 JA Single phas...

Страница 7: ...causes the motor to rotate Setting the operation switch to the STAND BY side causes the motor to stop FUNCTION key This key is used to switch the function Setting dial This setting dial is used to ch...

Страница 8: ...s or vacuum Altitude Up to 1000 m 3300 ft above sea level 3 2 Installing the motor Installing the parallel shaft combination type Drill tapped holes in the mounting plate and secure the product with t...

Страница 9: ...ng is attached to the flange of the motor Do not pinch the O ring when assembling the motor and gearhead Pinching the O ring causes a grease leak from the gearhead Output shaft pinion of motor Gearhea...

Страница 10: ...with cooling fan 90 W When installing a motor with cooling fan onto a device leave 10 mm 0 39 in or more behind the fan cover or open a ventilation hole so that the cooling inlet on the back of the m...

Страница 11: ...xcessive or abrupt force to the hollow output shaft when inserting a load shaft into the hollow output shaft Excessive or abrupt force may damage the gearhead internal bearings Installing the safety c...

Страница 12: ...lb 10 mm 0 39 in 20 mm 0 79 in Distance from output shaft end Axial load Radial load 10 mm 0 39 in 20 mm 0 79 in SCM26 50 11 2 110 24 Not to exceed one half the motor s mass SCM315 40 9 60 13 5 SCM42...

Страница 13: ...rder to keep within the operating ambient temperature Installation method Install the speed controller to a flat metal plate offering excellent vibration resistance Remove the front panel of the speed...

Страница 14: ...voltage of the product Single phase 110 115 VAC 200 VAC 220 230 VAC Single phase 100 VAC Connect the live side to terminal L or L1 and the neutral side to terminal N or L2 Ground the speed controller...

Страница 15: ...e not grounded Motor Ground close to the motor at a shortest distance using the Protective Earth Terminal of the motor Protective Earth Terminal Applicable crimp terminal Round crimp terminal with ins...

Страница 16: ...rotation speed Operation switch STAND BY RUN When the setting dial is turned the display blinks and the motor rotation speed is changed The amount of the rotation speed change varies depending on the...

Страница 17: ...r the motor rotates or stops 5 3 Switching the motor rotation direction The motor rotation direction can be changed with the rotation direction switch Rotation direction switch FWD REV Rotation direct...

Страница 18: ...tting Prevention of operation at power on alarm oFF Disable on Enable on Sets whether to enable or disable the prevention of operation at power on alarm When starting and stopping the motor by ON OFF...

Страница 19: ...BY the setting speed is displayed Rotation speed monitor Data setting The data can be locked so that the set value does not change Set on the rotation speed monitor screen If the ESC key is pressed an...

Страница 20: ...mal point 1 00 to 9 99 10 00 to 99 99 100 0 to 999 9 1000 or more Display the conveyor transfer speed To display the conveyor transfer speed set the conveyor speed reduction ratio which is calculated...

Страница 21: ...celeration time The acceleration time is set as the time needed for the motor to reach the 1000 r min from the standstill state Deceleration time The deceleration time is set as the time needed for th...

Страница 22: ...for about 1 second ON OFF ON OFF REV input FWD input Motor movement Forward direction Reverse direction Operation standstill Operation standstill FWD input REV input Motor shaft action ON OFF Rotates...

Страница 23: ...while the operation switch was set to the RUN side The power supply was turned on while the FWD input or REV input was being ON If the operation switch which is setting to the RUN side is set to the...

Страница 24: ...ecified combination Check the tables on p 6 for the model name The motor rotates in the direction opposite to the specified direction The rotation direction switch is set to the opposite side Check th...

Страница 25: ...roduct The speed controller uses semiconductor elements So be extremely careful when handling them Static electricity may damage the speed controller Inspection item Are the mounting screws of the mot...

Страница 26: ...available Maximum extension distance between the motor and speed controller 10 5 m 34 4 ft including 0 5 m 1 6 ft of the motor cable Speed controller Up to 10 m 32 8 ft can be extended Up to 3 pieces...

Страница 27: ...S2D15 JA SCM590JA GHRo SCM590HP JA US2D90 JA SCM315GV UA US2D15 UA SCM590JC GHRo SCM590HP JC US2D90 JC SCM315GV JC US2D15 JC SCM425JA GARo SCM425HP JA US2D25 JAB SCM315GV EC US2D15 EC SCM425JC GARo SC...

Страница 28: ...osure whose degree of protection is equivalent to IP54 or higher and supply a rated voltage via the insulation transformer The motor temperature rise tests Temperature rise tests required by the above...

Страница 29: ...ing methods will enable the product to be compliant with the EMC Directive Connecting mains filter for AC power supply line Install a mains filter which the customer provides in the power line in orde...

Страница 30: ...Use a connection cable supplied or accessory when extending the wiring distance between the motor and speed controller The EMC measures are conducted using the Oriental Motor connection cable Example...

Страница 31: ...as the torque rotation speed etc of the products check the Oriental Motor Website or catalog General specifications Item Motor Speed controller Operation environment Ambient temperature Single phase...

Страница 32: ...rd party products mentioned in this manual are recommended products and references to their names shall not be construed as any form of performance guarantee Oriental Motor is not liable whatsoever fo...

Отзывы: