9
Connecting the terminal of the motor and power supply
Terminal screw size: M3.5
Screw tightening torque: 1 N·m (8.8 lb-in)
Appropriate crimp terminal
3.7 ( 0.146) min.
9 (0.354) min.
7.8 (0.276) max.
(Ring terminal with insulation)
[Unit: mm (inch)]
9 (0.354) min.
3.7 (0.146) min.
7.8 (0.276) max.
(Fork terminal with insulation)
Connecting the control input terminal
Connection example
NOTE
●
Solenoids, high-frequency power sources and electric welders may cause the speed controller to
malfunction. Use an independent power source for the speed controller, and separate the control
and power lines.
Specifications of the switches and fuse
Power supply/Voltage
100 V/110 V/115 V (
ES01
)
200 V/220 V/230 V (
ES02
)
SW1
125 VAC
10 A
250 VAC
5 A
SW2, SW3
18 VDC
1 mA
SW4
125 VAC
10 A
250 VAC
5 A
R
0
, C
0
(Surge suppressor)
R
0
=5 ~ 200
Ω
C
0
=0.1 ~ 0.2
μ
F, 200 WV
R
0
=5 ~ 200
Ω
C
0
=0.1 ~ 0.2
μ
F, 400 WV
Fuse
Product certified under the UL/CSA248-14
standard or equivalent
250 VAC
10 A
Product certified under the UL/CSA248-14
standard or equivalent
250 VAC
5 A
NOTE
●
The control input terminals are not insulated from the AC power supply. Any equipment (programmable
controller, relay and/or switch) that will be connected to the control input terminals must have contact
ratings of 18 VDC and 1 mA min. Provide reinforced insulation for the parts which are in direct contact
with human operators.
●
Do not connect a controller that uses transistor output.
Applicable lead wire diameter: AWG28 ~ 16 (0.08 ~ 1.5 mm
2
)
Length of the lead wire which can be stripped: 5 ~ 7 mm (0.2 ~ 0.28 in.)
Tightening torque: 0.22 ~ 0.25 N·m (31 ~ 35 oz-in)
Flat blade-parallel tip type driver
Tip thickness
0.3 ~ 0.4 mm (0.01 ~ 0.02 in.)
Tip width
2 ~ 2.5 mm (0.08 ~ 0.1 in.)